USER MAINTENANCE INSTRUCTIONS
CLEANING THE PRE-MOTOR FILTER
1. To empty the EyeVac Professional Canister, turn the Control Dial to the Off position and unplug the unit.
2. Pull the Canister outward from the front of the Bin Cavity. Grasp the Canister Grip firmly and lift it out and
away from the EyeVac Professional Main Unit.
3. Holding the Canister firmly with one hand, grasp the Canister Lid Handle with the other hand and pull
the Lid straight up and out to remove.
4. Turn the Canister upside down over a trash can. Make sure you empty all dirt and debris from inside and
below the Bin. To ensure that all the dirt spills out, tap the side of the Canister gently against the edge of
the trash can. Re-attach the Canister Lid to the top of the Canister.
5. Clean Sensors, Inlet area, Canister, Canister Lid and Canister Cavity with a damp rag or towel. Do not
use soap or alcohol to clean sensors.
6. After all parts are fully dried, insert the assembled Canister with Lid fitted snugly into position and Pre-
Motor Filter locked into place and flush with Canister Lid. The 2 grooves in the bottom of the Bin fit easily
over the rod in the front of the unit. Grasp the Canister Grip and lock the Canister back into position.
NOTE: Make sure all parts are completely dry before reassembly.
HEALTH TIP: If you suffer from allergies or asthma, take the Canister outdoors to empty. As you empty
the dirt into the trash can, gently tap the Canister against the side of the can to remove loose debris.
To maintain optimal performance, the Pre-Motor Filter will need cleaning whenever the suction is not
strong. The Pre-Motor Filter must be clean and free of elements, which might hinder the flow of air.
1. Turn the control dial to the Off position and unplug the unit.
2. Pull the Canister outward from the front of the Bin Cavity. Grasp the Canister Grip firmly and lift it out and
away from the EyeVac Professional Main Unit. Locate the Pre-Motor Filter Handle. Before washing the
Pre-Motor Filter, please remove the screen and rinse with warm water, leave it out to dry, and replace the
screen before operating.
3. Remove the Pre-Motor Filter by grasping the Filter Handle and turn counter-clockwise to the unlock
position. Pull Filter straight up and out of the top of the Canister. Rinse under running water to clean. If
needed a mild soap and soft bristled brush can also be used.
IMPORTANT! Dry thoroughly before use.
4. Slide the Pre-Motor Filter back into the top of the Canister. Rotate clockwise to the “lock” position. Put the
Canister back into place.
5. If a new Filter is needed, replace with standard filter cartridges. Make sure that it fits snugly in the Filter
Holder. Replacement Filters are available through the Customer Service Department.
IMPORTANT! NEVER OPERATE THE EYEVAC PROFESSIONAL WITHOUT THE PRE-MOTOR FILTER
PROPERLY IN PLACE.