2  Safety Information and Notes 

2.1  Storage of this Manual 

Keep this user manual safe and in the vicinity of the device. All persons who have to work on 
or with the device should be advised on where the manual is stored. 

2.2  ATEX Special Conditions of Safe Use 

No special conditions of safe use are listed in the ATEX certificate  
 
List of Notes 

The notes supplied in this chapter provide information on the following. 

  Danger / Warning. 

o

  Possible hazard to life or health. 

  Caution 

o

  Possible damage to property. 

  Important 

o

  Possible damage to enclosure, device or associated equipment. 

  Information 

o

  Notes on the optimum use of the device 

 

Warning 

Installation  to  be  by  skilled  electricians  and  instructed  personnel  in 
accordance  with  national  legislation,  including  the  relevant  standards 
and,  where  applicable,  in  accordance  with  IEC  79.17  on  electrical 
apparatus for explosive atmospheres. 

 
Warning 

For  the  installation,  maintenance  and  cleaning  of  the  units,  it  is 
absolutely  necessary  to  observe  the  applicable  regulations  and 
provisions  concerned  with  explosion  protection  (EN60079-0,  EN  60079-
14) as well as the Accident Prevention Regulations. 

 
Warning 

The  iWAP200  must  NOT  be  operated  in  ATEX  Zone  0/20  or  Zone  1/21  
hazardous  areas.  Refer  to  the  declaration  of  conformity  for  ATEX 
certificate information. 

 
Warning         Do not exceed the Effective Isotropic Radiated Power (EIRP) for the gas 

group  in  which  the  iWAP200  will  be  operating.  The  RF  output  of  the 
transceiver will vary depending on the hardware and antenna used. The 
maximum hardware limit of the access point must be used to calculate 
the EIRP 

 software control by the user of the RF power is not allowed  

 
                          IIC 

 2W (+33dBm) 

                          IIB 

 3.5W (+35.4dBm) 

                          IIA 

 6W (+37.7dBm) 

 
Warning 

The iWAP200 MUST be earthed. 

 

Содержание iWAP200

Страница 1: ...Installation Operating Manual iWAP200...

Страница 2: ...is document is Copyright Extronics limited Extronics reserve the right to change this manual and its contents without notice the latest version applies Warranty For full details of the Extronics warra...

Страница 3: ...Input 13 3 1 7 Thermostat Control 13 3 1 8 Fitting the antennas 13 3 1 9 Mounting The Antennas 14 3 1 10 Setting to work 15 4 Intended Purpose Usage 16 4 1 Transportation and Storage 16 4 2 Authorize...

Страница 4: ...that Extronics can provide an OEM a solution to enable your WLAN network devices to be installed in hazardous areas The Extronics iWAP200 is designed for use with one to four standard antennas or Ext...

Страница 5: ...ng the relevant standards and where applicable in accordance with IEC 79 17 on electrical apparatus for explosive atmospheres Warning For the installation maintenance and cleaning of the units it is a...

Страница 6: ...re ensure the assembly is mounted using suitable fixtures Caution When powering the iWAP200 via POE do not apply an external power supply to the protection board Caution Never power the iWAP200 via PO...

Страница 7: ...nformation Do not exceed the Effective Isotropic Radiated Power EIRP limit for the country region of operation Information For legacy reasons the RF outputs of the iWAP200 remain approved in accordanc...

Страница 8: ...io 2 R2 on any manufacturers Wireless Access point A will be antenna port 1 B will be antenna port 2 and C will be antenna port 3 For example If you have ordered 1 N type connector for Radio 1 and 2 N...

Страница 9: ...supplied by Extronics are used these must be M20 sized cable glands meeting the requirements of EN60079 0 2009 for ATEX Category III GD equipment and not compromise the IP66 rating of the iWAP200 encl...

Страница 10: ...e to these screw terminals for the connection of the Ethernet input The pinouts on this terminal correspond with the standard cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be...

Страница 11: ...s made via a SC connector Important The fibre cable must enter the iWAP200 enclosure via a cable gland it therefore may be necessary to terminate the Fibre cable with the correct connector from within...

Страница 12: ...inouts on this terminal correspond with the standard Cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be made only use either the terminals or RJ45 connector NOT both Ethernet I...

Страница 13: ...s are currently not user configurable The default configuration is for the heaters to be turned on when the internal ambient temperature is between 20oC and 30oC and for the fans wireless hardware to...

Страница 14: ...ve been approved for use by Extronics for the area which they are to be installed may be used with iWAP200 Important Any plastic coated antenna shall have a warning label fitted to it stating WARNING...

Страница 15: ...ighten screws Refer to the original manufacturers instructions for a detailed information on setting the network to work correctly Important Ensure the lid is secure correct cable glands are fitted an...

Страница 16: ...red that they are not subjected to any excessive mechanical stresses 4 2 Authorized Persons Only persons trained for the purpose are authorized to handle the iWAP200 they must be familiar with the uni...

Страница 17: ...bserve the applicable regulations and provisions concerned with explosion protection EN 60079 0 EN 60079 14 as well as the Accident Prevention Regulations 4 5 Cleaning and Maintenance Intervals The cl...

Страница 18: ...e input option on ST connectors 100BaseLX 10 Single mode fibre on SC connectors Note that connectors may be specified as an option in the ordering data Output Connections Up to 6 energy limited extern...

Страница 19: ...Operating Manual 19 6 Enclosure Dimensions...

Страница 20: ...77 5000 Fax 44 0 845 277 4000 E mail Info extronics com W eb www extronics com xxxx Voltage EPSILON 08 ATEX 2394X II 3G Ex nAnL IIC T3 20 C Ta 70 C T4 20 C Ta 65 C T5 20 C Ta 30 C EPSILON 08 ATEX 2395...

Страница 21: ...ire Extronics to supply the wireless network hardware Specify option 3 Power Supply Universal 90 264VAC If heater option 7 selected the unit cannot have a universal voltage it will be either 115VAC or...

Страница 22: ...Operating Manual 22 9 EU Declaration of Conformity...

Страница 23: ...Operating Manual 23...

Отзывы: