![extronics iWAP200 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/extronics/iwap200/iwap200_installation-and-operating-manual_2457395010.webp)
Operating Manual
10
Caution
Only ever make one Ethernet cable to either the RJ45 connector or
Ethernet screw terminals
–
NEVER both.
Diagram 3.1.3.1
–
Mains Variant & PoE iWAP200 PCB
Connector
Description
Notes
110/230VAC
input
These screw terminals allow the connection of a
110/230VAC power supply. Pinouts are; 1 = Live, 2 =
Neutral, 3 = Earth. If AC powered, no PoE is
required.
Do not apply AC voltage if
powering with PoE
Chassis Earth
There are two terminals which allow a connection to
earth. When the iWAP200 is delivered one of these
terminals will be connected to the enclosure. The
second earth terminal spare.
Ethernet & PoE
Input (Terminals)
Connect a Cat-5 cable to these screw terminals for
the connection of the Ethernet input. The pinouts on
this terminal correspond with the standard cat-5
TIA/EIA-568-B T568B wiring methods.
Only one Ethernet input
should be made, only use
either the terminals or RJ45
connector
NOT
both.
Ethernet & PoE
Input (RJ45)
This allows the connection of a standard Cat-5 cable
with plugs.
Only one Ethernet input
should be made, only use
either the terminals or RJ45
connector
NOT
both.
Fibre Input
Allows a fibre connection to be made to the iWAP200
board. The connector will be a ST connector for
multimode fibre input, or a SC connector for single
mode fibre
The copper Ethernet input is
disabled if the fibre module
is fitted
Table 3.1.3.2
–
iWAP200 Mains / PoE Variant Pinouts
Ethernet & PoE
Input (RJ45)
Ethernet & PoE
Input
(Screw Terminals)
Chassis
Earth
110/230VAC
Input
L N E
Fibre input
Tx Rx