![extronics iWAP200 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/extronics/iwap200/iwap200_installation-and-operating-manual_2457395012.webp)
Operating Manual
12
Diagram 3.1.5.1
–
24V Variant iWAP200 PCB
Connector
Description
Notes
24VDC input
These screw terminals allow the connection of a
24VDC power supply. Pinouts are; 1 = +24V, 2 =
0V/GND, 3 = Earth/cable outer sheath.
Chassis Earth
There are two terminals which allow a connection to
earth. When the iWAP200 is delivered from
Extronics’ factory
one of these terminals will be
connected to the enclosure. The second earth
terminal spare.
Ethernet Input
(Terminals)
Connect a Cat-5 cable to these screw terminals for
the connection of the Ethernet input. The pinouts on
this terminal correspond with the standard Cat-5
TIA/EIA-568-B T568B wiring methods.
Only one Ethernet input
should be made, only use
either the terminals or RJ45
connector
NOT
both.
Ethernet Input
(RJ45)
This allows the connection of a standard Cat-5
cable with plugs.
Only one Ethernet input
should be made, only use
either the terminals or RJ45
connector
NOT
both.
Fibre Input
Allows a fibre connection to be made to the
iWAP200 board. The connector will be a ST
connector for multimode fibre input, or a SC
connector for single mode fibre
The copper Ethernet input is
disabled if the fibre module is
fitted
Table 3.1.5.2
–
iWAP200 24VDC Variant Pinouts
Ethernet Input
(RJ45)
Ethernet Input
(Screw Terminals)
Chassis
Earth
24 VDC Input
+ 0 E
Fibre input
Tx Rx