extronics iWAP200 Скачать руководство пользователя страница 16

Operating Manual         

 

 

16 

4  Intended Purpose Usage 

 

Important 

Before setting the units to work read the technical documentation  

 

carefully. 

 

Important 

The latest version of the technical documentation  or the corresponding 
technical supplements is valid in each case. 

 
The  iWAP200  is  built  using  modern  components  and  is  extremely  reliable  in 
operation;  however  it  must  only  be  used for  its  intended  purpose.  Please  note  that 
the  intended  purpose  also  includes  compliance  with  the  instructions  issued  by  the 
manufacturer for installation, setting up and service.   
 
Any other use is regarded as conflicting with the intended purpose. The manufacturer 
is  not  liable  for  any  subsequent  damage  resulting  from  such  inadmissible  use.  The 
user bears the sole risk in such cases. 
 

4.1  Transportation and Storage 

All iWAP200 devices must be so transported and stored that they are not subjected 
to any excessive mechanical stresses. 
 

4.2  Authorized Persons 

Only persons trained for the purpose are authorized to handle the iWAP200; they 
must be familiar with the unit and must be aware of the regulation and provisions 
required for correct installation as well as the relevant accident prevention 
regulations.  

4.3  Cleaning and Maintenance 

The iWAP200 and all its components require no maintenance and are self-
monitoring. All work on the iWAP200 by personnel who are not expressly qualified for 
such activities will cause the guarantee to become void. 
 

4.3.1 

Screw Thread Lubrication 

The threads of the lid screws and inserts have been coated with a thin layer of Rocol 
251 stainless steel anti-seize grease. It is recommended that this grease should be 
periodically renewed if the lid is  opened frequently, to prevent the stainless threads 
from binding. 
 

Warning 

Use  only  Rocol  251  or  Loctite  771  as  thread  lubricants,  as  other 
materials  may  damage  the  gasket  and  invalidate  the  IP  rating  of  the 
enclosure 

 

Содержание iWAP200

Страница 1: ...Installation Operating Manual iWAP200...

Страница 2: ...is document is Copyright Extronics limited Extronics reserve the right to change this manual and its contents without notice the latest version applies Warranty For full details of the Extronics warra...

Страница 3: ...Input 13 3 1 7 Thermostat Control 13 3 1 8 Fitting the antennas 13 3 1 9 Mounting The Antennas 14 3 1 10 Setting to work 15 4 Intended Purpose Usage 16 4 1 Transportation and Storage 16 4 2 Authorize...

Страница 4: ...that Extronics can provide an OEM a solution to enable your WLAN network devices to be installed in hazardous areas The Extronics iWAP200 is designed for use with one to four standard antennas or Ext...

Страница 5: ...ng the relevant standards and where applicable in accordance with IEC 79 17 on electrical apparatus for explosive atmospheres Warning For the installation maintenance and cleaning of the units it is a...

Страница 6: ...re ensure the assembly is mounted using suitable fixtures Caution When powering the iWAP200 via POE do not apply an external power supply to the protection board Caution Never power the iWAP200 via PO...

Страница 7: ...nformation Do not exceed the Effective Isotropic Radiated Power EIRP limit for the country region of operation Information For legacy reasons the RF outputs of the iWAP200 remain approved in accordanc...

Страница 8: ...io 2 R2 on any manufacturers Wireless Access point A will be antenna port 1 B will be antenna port 2 and C will be antenna port 3 For example If you have ordered 1 N type connector for Radio 1 and 2 N...

Страница 9: ...supplied by Extronics are used these must be M20 sized cable glands meeting the requirements of EN60079 0 2009 for ATEX Category III GD equipment and not compromise the IP66 rating of the iWAP200 encl...

Страница 10: ...e to these screw terminals for the connection of the Ethernet input The pinouts on this terminal correspond with the standard cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be...

Страница 11: ...s made via a SC connector Important The fibre cable must enter the iWAP200 enclosure via a cable gland it therefore may be necessary to terminate the Fibre cable with the correct connector from within...

Страница 12: ...inouts on this terminal correspond with the standard Cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be made only use either the terminals or RJ45 connector NOT both Ethernet I...

Страница 13: ...s are currently not user configurable The default configuration is for the heaters to be turned on when the internal ambient temperature is between 20oC and 30oC and for the fans wireless hardware to...

Страница 14: ...ve been approved for use by Extronics for the area which they are to be installed may be used with iWAP200 Important Any plastic coated antenna shall have a warning label fitted to it stating WARNING...

Страница 15: ...ighten screws Refer to the original manufacturers instructions for a detailed information on setting the network to work correctly Important Ensure the lid is secure correct cable glands are fitted an...

Страница 16: ...red that they are not subjected to any excessive mechanical stresses 4 2 Authorized Persons Only persons trained for the purpose are authorized to handle the iWAP200 they must be familiar with the uni...

Страница 17: ...bserve the applicable regulations and provisions concerned with explosion protection EN 60079 0 EN 60079 14 as well as the Accident Prevention Regulations 4 5 Cleaning and Maintenance Intervals The cl...

Страница 18: ...e input option on ST connectors 100BaseLX 10 Single mode fibre on SC connectors Note that connectors may be specified as an option in the ordering data Output Connections Up to 6 energy limited extern...

Страница 19: ...Operating Manual 19 6 Enclosure Dimensions...

Страница 20: ...77 5000 Fax 44 0 845 277 4000 E mail Info extronics com W eb www extronics com xxxx Voltage EPSILON 08 ATEX 2394X II 3G Ex nAnL IIC T3 20 C Ta 70 C T4 20 C Ta 65 C T5 20 C Ta 30 C EPSILON 08 ATEX 2395...

Страница 21: ...ire Extronics to supply the wireless network hardware Specify option 3 Power Supply Universal 90 264VAC If heater option 7 selected the unit cannot have a universal voltage it will be either 115VAC or...

Страница 22: ...Operating Manual 22 9 EU Declaration of Conformity...

Страница 23: ...Operating Manual 23...

Отзывы: