![Extron electronics XTP T USW 103 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/extron-electronics/xtp-t-usw-103/xtp-t-usw-103_user-manual_2457236018.webp)
XTP T USW 103 Switcher • Installation
10
RS-232 and IR Over XTP Communication
The RS-232 and IR Over XTP connector is for pass-through transmission of serial signals,
such as projector control signals, and infrared data. To pass bidirectional serial command
signals between XTP-compatible devices, connect a control device to the three poles
(Tx, Rx, and G) under “RS-232” of the 5-pole captive screw connector. To transmit and
receive IR signals, connect a control device to the three poles (G, Tx, and Rx) under “IR.”
The ground (G) pole is shared.
NOTE:
RS-232 and IR data can be transmitted or received simultaneously (see figure 8
below for wiring considerations).
Tx/Rx
Pins
Rx
Tx
RS-232
Rx
Tx
Tx
Rx
Rx
Tx
Custom
IR Device
RS-232 Device
G
G
G
IR
Figure 8.
Wiring the RS-232 and IR Over XTP Connector
ATTENTION:
•
The length of the exposed wires in the stripping process is important.
•
La longueur des câbles exposés est importante lorsque l’on entreprend de les
dénuder.
•
The ideal length is 3/16 inch (5 mm).
•
La longueur idéale est de 5 mm (3/16 inches).
•
Any longer and the exposed wires may touch, causing a short circuit between
them.
•
S’ils sont un peu plus longs, les câbles exposés pourraient se toucher et provoquer
un court circuit.
•
Any shorter and the wires can be easily pulled out even if tightly fastened by the
captive screws.
•
S’ils sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les
vis captives.