background image

 Audio output

Speaker output ..............................

  1 mono, 86 dB SPL, 0.1 watt, 0.1 m, half space

Frequency response ........................

  750 Hz to 20 kHz, ±5 dB

Playback format(s) ..........................

  WAV files: 8 bit PCM, mono, 8 kHz sampling

 General

Power supply ..................................

  External:

 

Input: 100-240 VAC, 50-60 Hz

 

Output: PoE 802.3af compliant, 48 VDC, 0.35 A, 16.8 watts

Power consumption

Device .....................................

  10.0 watts, 48 VDC (PoE)

Device and power supply .........

  13.1 watts, 48 VDC (PoE)

Power over Ethernet (PoE) input requirements

 

Complies with PoE 802.3af, class 3

Temperature/humidity ....................   Storage: -4 to +158 °F (-20 to +70 °C) / 10% to 90%, noncondensing 

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling ..........................................   Convection, vents on top rear
Thermal dissipation

Device .....................................

  34.2 BTU/hr

Device and power supply .........

  44.7 BTU/hr

Mounting

Furniture or wall mount ...........

  Set on tabletop or mount to optional VESA D 75 mm panel mount kit

Adjustment ranges .........................   Tilts through a 45° range

Enclosure type

 ................................  Plastic

 

TLP 710MV and TLP 710TV • Specifications

38

Содержание TLP 710MV

Страница 1: ...68 2028 01 Rev A 09 11 TLP 710MV and TLP 710TV User Guide TouchLink TouchLink Touchpanel Control Systems ...

Страница 2: ...al verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zurückgreifen können Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der Benutzerdokumentation Keine Zusatzgeräte V...

Страница 3: ...ted in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOT...

Страница 4: ...xamples of computer or device responses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH...

Страница 5: ...nfigurator and Global Configurator 18 Using the TouchLink Panel Web Pages 19 Updating the Firmware 21 Updating Firmware Using Extron Firmware Loader 21 Updating Firmware Using GUI Configurator 22 Updating Firmware from a Web Browser 23 Using GUI Configurator 24 Using Global Configurator 29 Specifications 34 Accessories and Part Numbers 40 Included Parts 40 Optional Parts 40 Mounting 41 Rack Mounti...

Страница 6: ...TLP 710MV and TLP 710TV Contents vi ...

Страница 7: ...an be wall or rack mounted The TLP 710TV can be placed on a desktop or VESA mounted on a wall or furniture using the Extron LPVM 1 kit part number 60 1099 02 Features 7 inch LCD screen displays a range of graphic objects and text on a 800x480 pixel screen Touch screen overlay provides simple and intuitive control over a range of functions by touching the icons displayed on the screen Video preview...

Страница 8: ...y Relay Relay Extron IR Emitter Extron DTP DVI 301 Rx Receiver Extron DTP DVI 301 Tx Transmitter Projector Extron IPL 250 IP Link Control Processor Figure 1 TLP 710MV Application Diagram Programmable LEDs can be user defined to provide feedback about various system states Light sensor adjusts LCD screen backlighting to compensate for ambient lighting Motion sensor When no motion is detected for a ...

Страница 9: ... resolution at 32 bit color Network Connection 10 Mbps 100 Mbps recommended Windows compatible mouse or other pointing device Global Configurator version 3 3 or later GUI Configurator version 1 3 or later Other Hardware An Extron IP Link control interface must also be connected to the same network domain as the TouchLink panel Suggested models include IPL T S series for example IPL T S4 IPL 250 IP...

Страница 10: ...focuses light onto the sensor When no motion has been detected for a user defined period of time the unit goes into sleep mode When motion is detected by the sensor the screen display is restored and active b Microphone is located below the LCD screen c Speaker one located under the screen on the left side of the panel provides audible feedback for the user d Programmable LEDs one on each top corn...

Страница 11: ... the level of ambient light and adjusts the screen brightness The sensor can be viewed only from above the panel Reset Buttons and LED The front bezel is removed by inserting the Extron removal tool into the slots on the top of the unit Behind the bezel are two buttons and an LED h ij Figure 4 TLP 710MV Front Panel with the Bezel Removed h Menu button activates the on screen menus for calibrating ...

Страница 12: ...as shown below NOTES Extron recommends using the Power over Ethernet power supply This 12 VDC 1 0 A power supply should be used only for setup or troubleshooting If both power supplies are connected to the TLP 710MV the PoE power supply takes precedence Power Receptacle DC Power Cord Captive Screw Connector AC Power Cord Ground 12 VDC External Power Supply 12 VDC 1 A SECTION A A Ridges Smooth Powe...

Страница 13: ... video luminance gain VID Y S video chrominance gain C and sharpness S For composite video signals the gain is controlled by the VID Y adjustment Insert a small Phillips head screwdriver into the recess and turn clockwise to increase adjustment or counterclockwise to decrease m MTP input A twisted pair cable terminated with an RJ 45 connector provides video and audio input from an Extron MTP trans...

Страница 14: ...ed power supply voids all regulatory compliance certification and may damage the supply and end product Extron power supplies are certified to UL CSA 60950 1 and are classified as LPS Limited Power Source Use of a non LPS or unlisted power supply will void all regulatory compliance certification Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall c...

Страница 15: ...d or green and can blink or light steadily in response to user defined events These can be seen more clearly in the figure below e LCD screen has a 800x480 resolution with a touch overlay A graphical user interface designed using the Extron GUI Configurator software displays buttons text or icons on the screen page 24 These are configured for a range of user defined functions using the Extron Glob...

Страница 16: ...on removal tool see page 45 m h i j k n l o Figure 9 TLP 710TV with the Stand and Cover Removed The following features and connections are available through the back panel h Menu button activates the on screen menus for calibrating the unit see page 14 i Reset button allows the unit to be reset in any of four different modes For further information see Reset Modes on page 47 j Reset LED provides f...

Страница 17: ...ring captive screw connectors l MTP signal adjustments Three MTP signal adjustments are available for S video luminance gain VID Y S video chrominance gain C and sharpness S For composite video signals the gain is controlled by the VID Y adjustment Insert a small Phillips head screwdriver into the recess and turn clockwise to increase adjustment or counterclockwise to decrease m MTP input A twiste...

Страница 18: ... Extron recommends using a Power over Ethernet PoE power supply Use a straight through Ethernet cable to connect the power supply to a switch or router This cable carries network information from the switch or router to the power supply input A second straight through cable carries the network information and 48 VDC from the power supply to the TLP 710TV Connect the IEC power cord to a convenient ...

Страница 19: ...ecuring Cables o VESA mounting holes Four holes are arranged in a pattern that is in accordance with the VESA FDMI standard type D 75 mm See page 46 for more information about mounting the TLP 710TV with the Extron LPVM 1 part number 60 1099 02 TLP 710MV and TLP 710TV Panel Features 13 ...

Страница 20: ...deo that can be selected by pressing the appropriate button at the left edge of the screen There is also an Exit button at the bottom left corner of the screen This button applies and saves any changes and closes the menu screens Main Screen Main Volume Time Network Video Exit On On Down Up Sleep timer 300 Sec Down Up Backlight 073 Auto Backlight Wake on Motion PoE Active Figure 13 Main Screen Val...

Страница 21: ...is detected near the unit Use the on screen buttons to toggle the Auto Backlight or Wake on Motion options between Off and On Volume Screen Exit Master 120 Click 120 Sounds 120 Down Up Down Up Down Up Down Up Line In 120 Main Volume Time Network Video Figure 14 Volume Screen Press the Down or Up buttons to highlight one of the adjustable audio features Use the Down and Up buttons to adjust the fol...

Страница 22: ... Screen Set the IP Address or Subnet Mask by pressing the appropriate button When one of the buttons is selected an on screen keypad appears that allows the user to select Clear digits between 0 and 9 and dot NOTE The factory default IP address for both the TLP 710MV and TLP 710TV is 192 168 254 254 The default subnet mask is 255 255 0 0 Consult with your IT Department to ensure these addresses ar...

Страница 23: ...255 default 128 Touch Calibration Screen After setting the values press the Menu button a second time to calibrate the touch area of the Touchpanel Press and Hold Highlighted Box Until Color Changes Figure 18 Touch Calibration Screen Press on the green box until the color reverts to gray with a white border and a second box is highlighted Repeat until all four boxes have been pressed and calibrate...

Страница 24: ...d from the TLP unit to Global Configurator where control functions are assigned to the text and graphic items in the layout After assigning the control functions the project is rebuilt and uploaded to the controller The GUI Configurator and Global Configurator programs provide versatility and adaptability for configuration and control of an A V system as it grows and evolves Installing the Softwar...

Страница 25: ...gate to GUI Configurator or Global Configurator and click Download next to the program Follow the on screen instructions to complete installation A folder is created on the C drive and an icon may be placed on the desktop Using the TouchLink Panel Web Pages Both the TouchLink panels have default web pages that can be used to read and change the current settings of the panels The web pages can be a...

Страница 26: ...ge 16 in the on screen menus Figure 20 System Settings Page 3 Selecting Passwords allows the user to set passwords for an administrator and a user To set a password follow the instructions at the top of the page Figure 21 Passwords Page 4 To upgrade the firmware select Firmware Upgrade For more detailed instructions see Updating Firmware from a Web Browser on page 23 TLP 710MV and TLP 710TV Config...

Страница 27: ...Loader 1 Power on a computer that is connected to the same network as the touchpanel 2 Install the Extron Firmware Loader utility onto the computer if it is not already present This is on the software disc that ships with unit or can be downloaded free of charge from the Extron website www extron com To install from the disc insert the disc into the DVD ROM drive of the computer and follow the sam...

Страница 28: ...h the TLP 710MV or TLP 710TV listed in the device pane 10 Click Begin The firmware transfer begins and takes approximately three minutes When the Total Progress box shows Completed select Exit from the File menu to exit Firmware Loader Updating Firmware Using GUI Configurator Set up the computer and touchpanel as described in steps 1 and 2 in the previous section Updating Firmware Using Extron Fir...

Страница 29: ... of the TLP 710 unit into the address box The browser opens the TouchLink panel web pages see page 19 Figure 25 Firmware Upgrade Web Page 4 Click the Configuration tab at the top of the page and then select Firmware Upgrade from the sidebar on the left 5 Click the Browse button and navigate to the firmware file that was saved in step 4 6 Click Upload The Touchpanel screen shows the message Firmwar...

Страница 30: ...nning NOTE To configure the touchpanel use GUI Configurator version 1 3 or later To use the GUI Configurator program follow these instructions 1 Double click the desktop icon A splash screen appears momentarily and then the program opens at the main screen behind the GUI Configurator Start Options dialog box Figure 26 Opening GUI Configurator Figure 27 GUI Configurator Start Options Dialog Box TLP...

Страница 31: ...o be selected To work from a template users can choose from a range of factory loaded templates or from a template they have previously created Open an Existing Project Clicking OK opens a dialog box Figure 29 GUI Configurator Dialog Box to Open an Existing Project a Navigate to the existing file and select it To look at a project without altering it leave the Open as read only box unchecked b Cli...

Страница 32: ...re 30 GUI Configurator Download Project Dialog Box a In the dialog box that opens enter the IP address of the panel and use the Browse button to navigate to a folder where the file will be saved b Check Open the project and Close Download Manager c Click OK The project is downloaded to your computer and opens in GUI Configurator TLP 710MV and TLP 710TV Configuration Software 26 ...

Страница 33: ... the help file from the Help menu select Contents or press the F1 key while the program is running Figure 31 GUI Configurator Main Screen 4 To save the project select Save Project from the File menu If this is the first time saving the project file the Save As dialog box appears If the Save As dialog box appears a Browse for the location where the project file is to be saved b Enter a file name fo...

Страница 34: ...operty in the right pane and type in the correct IP address Update any other properties as required f Repeat steps 5c 5e to add further panels if required 6 Upload a project to a TouchLink panel as follows a From the Project menu select Upload to Selected Panels The Build Manager dialog box opens showing the build progress After the build is complete this dialog box closes and the File Upload Mana...

Страница 35: ... of the Global Configurator program For complete information about the program see the Global Configurator help file select Contents from the Help menu or press the F1 key while the program is running NOTE This section describes how to set up Global Configurator project with an IPL 250 While setting up a project with another IP Link product is similar see the Global Configurator help file for exac...

Страница 36: ...fault Telnet connection is port 23 and the default HTTP connection is port 80 so these values do not usually need to be changed If necessary set administrator and user passwords If required set the date and time Checking the Set Device as GlobalViewer Host box is optional For more information about GlobalViewer host see the Global Configurator help file TLP 710MV and TLP 710TV Configuration Softwa...

Страница 37: ... Enter the IP address of the IP Link controller The default value is 192 168 254 254 but this may have been changed Check with your IT Department to verify the address d Enter a display name into the text box This is what the device will be known as in the Global Configurator project e Checking the Make this device a GlobalViewer Host check box is optional f Set the Telnet port usually 23 and the ...

Страница 38: ...ble showing the IPL 250 and the available ports Figure 37 Configuring an IP Link Device 6 Select TouchPanel Port 1 The screen shows the available options for the TouchLink panel 7 Click Click here to add one Figure 38 Adding a TouchLink Panel TLP 710MV and TLP 710TV Configuration Software 32 ...

Страница 39: ... usually 23 and if necessary enter the password c Check the Import Apply Layout check box and click OK The window now shows the GUI from the TouchLink panel Figure 40 Touchpanel GUI Loaded Onto Global Configurator 3 9 Use Global Configurator to associate functions with the screen elements designed in GUI Configurator see the Global Configurator help file TLP 710MV and TLP 710TV Configuration Softw...

Страница 40: ...for project storage 16 MB for system use Control Ethernet interface Ethernet control communications port 1 RJ 45 female connector Ethernet data rate 10 100Base T half full duplex with autodetect Ethernet protocol ICMP IP TCP control UDP DHCP Telnet Default settings Link speed and duplex level autodetected IP address 192 168 254 254 Subnet mask 255 255 0 0 Default gateway 0 0 0 0 DHCP off Program c...

Страница 41: ...PL 0 1 watt 0 1 m half space Frequency response 750 Hz to 20 kHz 5 dB Playback format s WAV files 8 bit PCM mono 8 kHz sampling General Power supply External Input 100 240 VAC 50 60 Hz Output PoE 802 3af compliant 48 VDC 0 35 A 16 8 watts Power consumption Device 10 0 watts 48 VDC PoE Device and power supply 13 1 watts 48 VDC PoE Power over Ethernet PoE input requirements Complies with PoE 802 3af...

Страница 42: ... cm 8 69 22 1 cm 6 89 17 5 cm BOTTOM VIEW Product weight 2 3 lbs 1 0 kg Shipping weight 5 lbs 3 kg Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE c UL UL EMI EMC CE C tick FCC Class A ICES VCCI Environmental Complies with the applicable requirements of RoHS and WEEE MTBF 30 000 hours Warranty 3 years parts and labor touchpanel display and overlay...

Страница 43: ...DP DHCP Telnet Default settings Link speed and duplex level autodetected IP address 192 168 254 254 Subnet mask 255 255 0 0 Default gateway 0 0 0 0 DHCP off Program control Extron Global Configurator 3 3 or higher GUI Configurator for Windows Extron Simple Instruction Set SIS Microsoft Internet Explorer ver 6 or higher Telnet Control touchpanel Motion sensor On off Light sensor On off Video input ...

Страница 44: ...ply 13 1 watts 48 VDC PoE Power over Ethernet PoE input requirements Complies with PoE 802 3af class 3 Temperature humidity Storage 4 to 158 F 20 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Cooling Convection vents on top rear Thermal dissipation Device 34 2 BTU hr Device and power supply 44 7 BTU hr Mounting Furniture or wall mount Set on tabletop or moun...

Страница 45: ... SIDE VIEW Product weight 3 8 lbs 1 7 kg Shipping weight 7 lbs 3 kg Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE c UL UL EMI EMC CE C tick FCC Class A ICES VCCI Environmental Complies with the applicable requirements of RoHS and WEEE MTBF 30 000 hours Warranty 3 years parts and labor touchpanel display and overlay components are covered for 1 y...

Страница 46: ...er RM 710M rack mounting kit for TLP 710MV 70 970 01 BB 710M back box for TLP 710MV 70 971 01 EWB 710 wall box for TLP 710MV black 70 969 02 EWB 710 wall box for TLP 710MV white 70 969 03 LPVM 1 VESA mounting kit for TLP 710TV 60 1099 02 SMA 1 swivel mount adapter for TLP 710TV 70 747 01 6 Spanner head screwdriver 100 710 01LF PS 1210 C 12 VDC 1 0 A desktop power supply with captive screw connecto...

Страница 47: ... Tma 122 F 45 C specified by Extron Reduced air flow Install the equipment in the rack so that the equipment gets adequate air flow for safe operation Mechanical loading Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition Circuit overloading Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on...

Страница 48: ...5 MTP input Optional Extron recommends using the PoE power supply provided However the LAN port may be used as a network only connection Connect a 12 VDC 1 0 A power supply not provided to the 2 pole captive screw power input See the cautions on page 7 for very important information about power supplies 7 Push excess cables into the wall cavity 8 Ensure the four locking arms two at the top and two...

Страница 49: ...le providing both a network connection and power from a Power over Ethernet power supply Connect an S video or composite video source to the RJ 45 MTP input Optional Extron recommends using the Power over Ethernet power supply provided However the LAN port may be used as a network only connection Connect a 12 VDC 1 0 A power supply not provided to the 2 pole captive screw power input See the cauti...

Страница 50: ...el mount adapter This allows the unit to be mounted permanently yet swivel up to 180 in either direction 1 Remove the back cover and base cover using the provided Extron removal tool as described in Removing the TLP 710TV Base for VESA Mounting on the next page 2 Remove the screw holding the locking plate at the bottom of the base This releases the weight which can be removed from the top of the b...

Страница 51: ...emove the back cover by inserting the Extron removal tool provided into the notches on each side and prying off the cover 2 Remove the base cover using the Extron removal tool VESA mounting hole 4 Hinges 2 Cable Runway Spanner Drive Security Screws 2 for each hinge Figure 46 Removing the Base from the Touchpanel TLP 710MV and TLP 710TV Mounting 45 ...

Страница 52: ...move the base and back of the TLP 710TV as described in the previous section 2 If necessary connect the cables and zip tie them to the back of the touchpanel 3 Attach the small back cover provided Fit the bottom catches into the slots on the bottom of the panel and snap the side catches into place 4 Secure a VESA D 75 mm mount kit to the back of the TLP 710TV The photograph below shows the Extron ...

Страница 53: ...y not work correctly with an earlier version of the firmware Run or Stop Events 3 Hold down the Reset button for approximately 3 seconds until the Release LED blinks once Then release and press Reset momentarily less than 1 second within 1 second This mode turns events on or off NOTE Nothing happens if the momentary press does not occur within 1 second This mode is useful for troubleshooting Reset...

Страница 54: ...and the Middle East Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia 135 Joo Seng Road 04 01 PM Industrial Bldg Singapore 368363 Singapore Middle East Extron Middle East Dubai Airport Free Zone F12 PO Box 293666 United Arab Emirates Dubai This Limited Warranty does not apply if the fault...

Отзывы: