PVT RGB models
2a
2b
PVT RGB D
RGB OUT
A
B
PVT RGB AAP
6a
2b
6a
2a
Figure 2-10 — PVT RGB models rear panel features
Ç
RGB
A output
— Using CAT 5 UTP cable,
c
onnect this RJ-45
female output port labelled “RGB A out” to one of the two
input ports (labelled 1A and 2A) on the PVS 204SA switcher.
É
RGB
B output
— Using CAT 5 UTP cable,
c
onnect this RJ-45
female output port labelled “RGB A out” to one of the two
input ports (labelled 1B and 2B) on the PVS 204SA switcher.
Cable termination for PVT RGB models
N
The PVT cable termination method is specific for
PVT transmitters working with the PVS 204SA
switcher. DO NOT connect to an MTP system.
N
RJ-45 termination with CAT 5, CAT 5e, CAT 6, and
Skew-Free A/V UTP cable must comply with the
TIA/EIA T 568A wiring standards for all connections.
N
The cables must be wired exactly as shown in
figure 2-11, so that the output signals (video on cable A,
vertical sync and audio on cable B) are transmitted
correctly.
N
Cable B primarily carries the audio signal, the
vertical sync information, and 5 VDC to power
the PVT transmitter
.