NAV E 501 and NAV E 101 Encoders • Reference Information
70
Reference
Information
•
Mounting the Encoder
Mounting the Encoder
ATTENTION:
•
Installation and service must be performed by authorized personnel only.
•
L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
The 1-inch high, half-rack width encoder can be placed on a table, mounted in a rack, or
mounted under a desk or table.
Tabletop Use
Affix the included rubber feet to the bottom of the unit and place it in any convenient location.
Mounting kits
Mount the unit using any optional compatible mounting kit listed on the Extron website
(
https://www.extron.com
), in accordance with the directions included with the kit.
ATTENTION:
•
When mounting the encoder under furniture, mount the device upside-down to
ensure proper ventilation.
•
Si vous installez le encoder sous un mobilier, veillez à installer l’unité à l’envers pour
assurer une bonne ventilation.
For rack mounting, see “UL Rack-Mounting Guidelines,” below.
UL Rack-Mounting Guidelines
The following Underwriters Laboratories (UL) requirements pertain to the installation of the
unit into a rack.
•
Elevated operating ambient temperature
— If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature (TMA = +104 °F, +40 °C) specified
by Extron.
•
Reduced air flow
— Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
•
Mechanical loading
— Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.