![Extron electronics MLS 608 D SA Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/extron-electronics/mls-608-d-sa/mls-608-d-sa_user-manual_2457066081.webp)
Command
ASCII Command
(host to switcher)
Response
(switcher to host)
Additional
Description
Power Save Mode
Turn power save off
E
0PSAV
}
Psav
X3$]
Turn power save on
E
1PSAV
}
Psav
X3$]
View power save
E
PSAV
}
X3$]
View power save status.
Front panel security lockout (Executive Mode)
Enable Executive mode 1
1X
Exe1
]
Lock out front panel
buttons and knobs.
Enable Executive mode 2
2X
Exe2
]
Lock out front panel
buttons only.
Disable Executive mode
0X
Exe0
]
Unlock all front panel
controls.
View Executive mode
status
X
0
]
(or) 1
]
(or) 2
]
View the current status:
0 = off [default]; 1 =
on, lock all buttons and
knobs; 2 = on, lock input
buttons only.
Information Requests
View firmware
version
Q or 1Q
x.xx
]
View the firmware
version.
View part number
N
X3&]
View the part number
X3&
.
View AV input
I
Vid
X!
•
Aud
X!]
View current AV input.
View model name
1I
X3*]
View model name
X3*
.
View video signal
presence
LS
X3(
*
X3(
*
X3(
*
X3(
*
X3(
*
X3(
*
X3(
*
X3(]
Shows signal presence
for all inputs, 1-8.
View +1.5V FPGA
voltage
15S
+
X4)]
View internal temp
in °C
20S
+
X4!]
View audio mute
to DSP
40S
X4@]
NOTE:
X!
= Input selection: 0-8, 0 = no connection
X3$
= Power save mode: 0 = off (default), 1 = on
X3&
= Device part number: 60-1050-01 = MLS 608 D, 60-1050-02 = MLS 608 D MA, 60-1050-03 = MLS 608 D SA
X3*
= MLS 608 D, or MLS 608 D MA, or MLS 608 D SA
X3(
= Video signal status: 0 = video /TMDS not detected, 1 = video /TMDS detected, - = unknown
X4)
= Voltage in volts (V)
X4!
= Temperature in degrees C, response is three digits with leading zeros (for example 031 = 31°C)
X4@
= Audio mute to DSP: 0 = audio unmuted, 1 = audio muted