![Extron electronics IPCP 505 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/extron-electronics/ipcp-505/ipcp-505_user-manual_2455671030.webp)
IPCP 505 • Software-based Configuration and Control
22
IPCP 505 LAN port defaults:
•
IP address:
192.168.254.254
•
Gateway IP address:
0.0.0.0
•
Subnet mask:
255.255.0.0
•
DHCP:
off
•
Link speed and duplex level:
autodetected
NOTE:
Both the computer and the IPCP must be connected to the same subnet on a
LAN (using a straight-through cable). Alternatively, you can use a crossover Ethernet
cable to connect the controller directly to the Ethernet card in the computer.
The following instructions assume that you have already connected the PC to the LAN port
on the IPCP and powered on the controller and the PC.
Configuring the IPCP for Network Use Via Global Configurator
You can configure the IP address of the controller via an IP (Ethernet) connection using
Global Configurator (GC) software.
See the Global Configurator Help File
for basic
information on using the software and setting up a project. The “Add an IPCP 505 and Set
the IP Address” topic in the help file provides step-by-step instructions on how to use GC to
set up the IP address of the IPCP.
Configuring the IPCP for Network Use Via the ARP Command
The ARP (address resolution protocol) command tells the computer to associate the
MAC (media access control) address of the IPCP 505 with the assigned IP address. You
must then use the ping utility to access the controller, at which point the IP address of the
controller is reconfigured.
Use ARP to configure the IP address as follows:
1.
Obtain a valid IP address for the IPCP 505 from your network administrator.
2.
Obtain the MAC address (UID #) of the IPCP from the label on its rear panel. The MAC
address should have this format: 00-05-A6-xx-xx-xx.
3.
If the IPCP has never been configured and is still set for factory defaults, go to step
4
. If
not, perform a Mode 4 system reset. For detailed information on reset modes, see
ATTENTION:
•
The IPCP must be configured with the factory default IP address
(192.168.254.254) before the ARP command is executed.
•
L’IPCP doit être configuré avec l’adresse IP par défaut (192.168.254.254) avant
d’exécuter la commande ARP.
4.
To change to the new IP address, at the PC, access the command prompt, then enter
the
arp –s
command. Enter the desired new IP address for the unit and the MAC
address of the unit (listed on the
, see page 14). For example:
arp –s 192.168.197.7 00-05-A6-03-69-B0
Figure 14.
Sending the
arp –s
Command
After the arp -s command is issued, the controller changes to the new address and
starts responding to the ping requests, as described in the next step.