IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Communication and Control
48
Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Information request
General Information
I
Vid
X!
•
Aud
X!
•
Typ
X#
•
Std
X1)
•
Blk
X2*
•
...
Hrt
X1#
•
Vrt
X1#]
Query firmware version
Q
x.xx
]
View firmware version.
Query full firmware
version
*Q
x.xx.xxxx
]
View full firmware version.
Query part number
N
<part number>
]
View the device part
number.
View internal
temperature
E
20STAT
}
X1!]
View the temperature in
degrees Celsius.
Backup or restore configuration
Save box configuration
to file system
E
1*
{config type}
XF
}
Cfg1*
{config type}
]
Backup device
configuration.
Restore box
configuration from file
system
E
0*
{config type}
XF
}
Cfg0*
{config type}
]
Restore device
configuration.
NOTE:
{config type}
=
0
= IP config,
2
= box-specific parameters.
Device naming
Set unit name
24
EX1$
CN
}
Ipn
•
X1$]
Set the device name to
X1$
.
Set unit name to factory
default
24
E
•
CN
}
Ipn
•
X3#]
Reset the device name to
the factory default.
View unit name
E
CN
}
X1$]
View the device name.
NOTES:
X!
= Input selection
1-6
(IN1606) or
1-8
(IN1608 models)
X#
= Input video format
1
= RGB
2
= YUV
3
= RGBcvS
4
= S-video
5
= composite
6
= HDMI
X1)
= Input standard
0
= no signal detected on the current input
1
= NTSC 3.85
2
= PAL
3
= NTSC 4.43
4
= SECAM
-
= not applicable (occurs when the input is active RGB,
YUV, or HDMI signals)
X1!
= Internal temperature In degrees Celsius
X1#
= Horizontal and vertical frequencies
xxx.x
X1$
= Text label
Up to 63 characters
X2*
= Video mute
0
= off or disabled
1
= on or enabled (mute to black)
2
= mute all output sync
X3#
= Default name
A combination of model name and the last 3 pairs of the
MAC address