![Extron electronics IN1604 DTP Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/extron-electronics/in1604-dtp/in1604-dtp_user-manual_2457039015.webp)
IN1604 DTP and IN1604 HD Scalers • Installation
9
K
Remote Tally port
— If desired, to remotely identify the currently selected input, plug a
locally-constructed device into the 5-pole captive screw connector. Connect the power
wire for the device into the +V pin and connect the ground wire for the each indicator
into the corresponding tally out pin, 1, 2, 3, or 4.
When an input is selected, by either contact closure of front panel selection, the
corresponding tally out pin shorts to ground, closing the circuit and lighting the
connected indicator (LED).
This connector can also be used with Extron “Show Me”
cables and the Contact Closure input connector. For each
“Show Me” cable, connect the red pigtail to the associated
pin of the Contact Closure input connector and the black
pigtail to the associated pin on the Tally Out connector (see
the diagram to the right). For more information and installation
details for the Extron “Show Me” cable, see the
“Show Me”
Cable Series Setup Guide
at
www.extron.com
.
L
Remote RS-232 connector
— Connect a host device to the three rightmost poles of
the 5-pole captive screw connector for RS-232 serial control. The scaler uses a protocol
of 9600 baud, 1 stop bit, no parity, and no flow control.
Connection Details
Analog Video Wiring
Pinout Table for 15-pin HD Connectors
Pin
RGBHV
RGBs
Component
S-video
Composite
1
Red
Red
R-Y
2
Green
Green
Y
Luma
Video
3
Blue
Blue
B-Y
Chroma
4
5
H Sync Return
C Sync Return
6
Red Return
Red Return
R-Y Return
7
Green Return
Green Return
Y Return
L Return
Video Return
8
Blue Return
Blue Return
B-Y Return
C Return
9
10
V Sync Return/
DDC Return
DDC Return
11
12
EDID/DDC
EDID/DDC
1
5
11
15
13
H Sync
C Sync
14
V Sync
15
EDID/DDC
EDID/DDC
TALLY OUT
CONTACT IN
Tx Rx G
3
2
1
4 +V
1 2 3 4 G
RS-232
REMOTE
Red
Black
“Show Me” Cable
Pigtail