Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional description
V
ideo mute
Mute output
1B
Blk1
]
Blank the video output.
Unmute output
0B
Blk0
]
Output video.
Show video mute status
B
X!]
V
ideo ouput mute status is
X!
(0 = unmuted, 1 = muted).
Output sync format
Set output sync format
6*
X@
#
Syn
X@]
Set the sync format. 0 = RGBHV
, 1 = RGBS, 2 = RGsB.
Show output sync format
6#
X@]
Output sync polarity
Set output to sync negative
7*1#
Pol1
]
Receiver
output
sync
(H
and
V
for
RGBHV
, S
for
RGBS,
or
s for RGsB) is always negative.
Set output sync to follow
the input
7*0#
Pol0
]
Output sync follows the video sync input to the
transmitter
.
Show the sync polarity
7#
X#]
Horizontal shift
Set a horizontal position
X$
H
Hph
X$]
Set horizontal centering to
X$
.
Incr
ement position.
+H
Hph
X$]
Shift the image one pixel to the right.
Decr
ement position
-H
Hph
X$]
Shift the image one pixel to the left.
Show position
H
X$]
Command/r
esponse table for SIS commands
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional description
V
ertical shift
Set a vertical position
X$
/
Vph
X$]
Set vertical centering to
X$
.
Incr
ement position
+/
Vph
X$]
Shift the image up one line.
Decr
ement position
-/
Vph
X$]
Shift the image down one line.
Show position
/
X$]
Horizontal start
N
When
the
contr
olling
PC
is
connected
to
the
r
eceiver
, the
FOX
500
can
perform
this
command
only
if
the
fiber
2
cable
is
connected.
The
unit
returns
the
E14
err
or
if
fiber
2
is
not
connected.
Set a start position
X%
)
Hst
X%]
Set the horizontal location of the first active pixel in the
active window
.
Example:
128*)
Hst128
]
Set pixel 128 as the first active pixel.
Incr
ement start position
+)
Hst
X%]
Shift the horizontal start position one pixel to the right.
Decr
ement start position
-)
Hst
X%]
Shift the horizontal start position one pixel to the left.
Show start position
)
X%]
Pixel phase
N
When
the
contr
olling
PC
is
connected
to
the
r
eceiver
, the
FOX
500
can
perform
this
command
only
if
the
fiber
2
cable
is
connected.
The
unit
returns
the
E14
err
or
if
the
fiber
2
cable
is
not
connected.
Set a pixel phase value
X^
U
Phs
X^]
Set the pixel phase value to
X^
.
Example:
10U
Phs10
]
Set the pixel phase value to 10.
Incr
ement pixel phase
+U
Phs
X^]
Incr
ease pixel phase value by 1..
Decr
ement pixel phase
-U
Phs
X^]
Decr
ease pixel phase value by 1.
Show pixel phase
U
X^]