FOX 500 Tx/Rx • Installation
Installation, cont’d
2-12
FOX 500 Tx/Rx • Installation
2-13
k
RS-232 Over Fiber port —
If you want the
FOX 500 to pass serial command signals to
the receiver, for serial control of a projector
for example, connect the host device to the
transmitter via three poles of this 5-pole captive
screw connector. See "Rear panel serial ports
connections" on page 2-14 to wire this connector.
N
If you connect only one fiber optic cable (item
n
,
below),
you will not receive reports from the controlled device. To
receive responses from the controlled device, you will need
to install two fiber optic cables.
N
The FOX 500 can pass RS-232 commands and responses
at rates up to 38400 baud.
l
Remote RS-232 port —
For serial control of the receiver,
connect a host device, such as a computer, touch panel control,
or RS-232 capable PDA, to the transmitter via three poles of this
5-pole captive screw connector.
See "Rear panel serial ports
connections" on page 2-14 to wire this connector.
See chapter 4, Remote Control, for definitions of the SIS
commands (serial commands to control the transmitter via this
connector).
m
Alarm outputs port
— For remote monitoring of
the status of fiber optic link 1, connect a locally-
constructed or furnished device to the receiver
via two poles of this 5-pole captive screw
connector. When the receiver does not detect a
light link on fiber cable Optical 1, pin 1 and pin 2 of this port
are shorted together.
n
Fiber optic connectors and LEDs
—
W
These units output continuous invisible light,
which may be harmful and dangerous to the eyes;
use with caution. For additional safety, plug the
attached dust caps into the optical transceivers
when the fiber optic cable is unplugged.
N
Ensure that you use the proper fiber cable for your
transmitter/receiver pair. Typically, singlemode fiber has a
yellow jacket and multimode cable has an orange jacket.
N
Only one fiber optic cable, Optical 1, is required for video,
audio, and serial command transmission. But, if you
connect only one fiber optic cable, you will not receive
RS-232 reports from the controlled device, and there will
be reduced front panel, Windows-based control program,
and RS-232 command functionality on the RX unit. To
receive responses from the controlled device and for full
functionality, you will need to install both fiber optic
cables.
Optical 1
— For all one-way video, audio, and
serial communications from the transmitter to
the receiver, connect a fiber optic cable to the
Optical 1 LC connector.
Connect the free end of this fiber optic cable
to the Optical 1 connector on the FOX 500 Tx
transmitter
(item
g
in "Transmitter rear panel
connections")
.
Optical 2
— For all one-way serial
communications from the receiver to the
transmitter, connect a fiber optic cable to the
Optical 2 LC connector.
Connect the free end of this fiber optic cable
to the Optical 2 connector on the FOX 500 Tx
transmitter
(item
g
in "Transmitter rear panel
connections")
.
Link 1 and Link 2 LEDs
— When lit, the link
is active (light is received).
o
AC power connector —
Plug a standard IEC power cord
into this connector to connect the receiver to a 100 VAC to
240 VAC, 50 or 60 Hz power source.
REMOTE
RS-232
ALARM
Tx Rx
1 2
OPTICAL
1 2*
*
OPTIONAL FOR
RETURN DATA
LINK
LINK
OPTICAL
2* 1
*
OPTIONAL FOR
RETURN DATA
LINK
LINK
RS-232
OVER FIBER
Tx Rx
NA
REMOTE
RS-232
ALARM
Tx Rx
1 2
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203