Overscan
— Lets you select a default overscan mode to apply to SMPTE input rates
(480i, 576i, 480p, 576p, 720p, 1080i, 1080p, 2K, and 4K). This zooms and crops
SMPTE inputs to mask edge effects and ancillary data that may occur in broadcast
signals. The selections are
0%
(default),
2.5%
, and
5%
.
NOTE:
If the overscan mode is not 1%, when Auto-Image is performed on an
SMPTE input rate, it refers to the default input values for sizing and centering
instead of performing a true Auto-Image.
•
Factory Reset
— Resets the unit to its factory default values (removing any
user-specified values) while retaining the current firmware version.
To reset using the OSD menu, press and hold the
Enter
button until
Factory
Reset
is displayed (approximately 5 seconds). The message remains for approximately
1 minute after the reset is complete to allow time for the display device to sync with
the DSC output.
NOTE:
The equivalent SIS command is <ESC>
ZXXX
<CR>.
For other reset methods, see
on page 41.
Communications Submenu
This menu enables you to view the RS-232 remote port baud rate, port type, and the unit
MAC address, and to edit the IP settings.
Figure 30.
Communications Screen
DSC HD-HD 4K Plus A Series • Operation
35