Programmer’s Guide, cont’d
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
4-22
Command/Response Table for IP-specific SIS Commands
Symbol definitions
X3)
= Matrix name
(Up to 240 alphanumeric characters)
N
The following characters are invalid in the name: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : | \ and ?.
X3!
= Default name
Factory default name (model name
+ last 3 pairs of MAC address)
X3@
= Time and date (for set)
In the format MM/DD/YY•HH:MM:SS,
where
:
MM = month: 01 (January) through 12 (December)
DD = 01 through 31
YY = 00 through 99
HH = 00 through 23
MM = 00 through 59
SS = 00 through 59
X3#
= Time and date (for read)
In the format Day,•DD•Mmm•YYYY•HH:MM:SS,
where
:
Day = weekday: Mon through Sun
DD = 01 through 31
Mmm = month: Jan through Dec
YYYY = 2000 through 2099
HH = 00 through 23
MM = 00 through 59
SS = 00 through 59
X3$
= GMT offset
–12.0 t14.0. Hours and minutes removed from GMT
X3%
= Daylight Saving Time
0 = Daylight Saving Time off/ignore
1 = Daylight Saving Time on (northern hemisphere)
2 = Daylight Saving Time on (Europe)
3 = Daylight Saving Time on (Brazil)
X3^
= IP address
###.###.###.###
X3&
= Hardware (MAC) address
##-##-##-##-##-##
X3*
= Number of open connections
0 - 255
X3(
= Password
12 alphanumeric characters
N
The following characters are invalid in passwords: {space} + ~ , @ = ` [ ] { } < > ‘ “ ; : | \ and ?.
X4)
= Domain name
Standard domain name rules apply (for example:
)
N
The following characters are invalid in a domain name: {space} + ~ , = ` [ ] { } < > ‘ “ ; : | \ and ?. The @ character is acceptable only as
the lead-in to the domain name (such as @extron.com).
X4!
= E-mail account
65 - 72. 65 = e-mail recipient 1, 66 = 2, 67 = 3, ... 72 = recipient #8
X4@
= E-mail address
Typical e-mail address format (for example:
)
X4#
= Notify when?
0 = no response
3 = both 1 & 2
1 = fail/missing
4 = suspend
2 = fixed/restored
X4$
= Notification selections
Matrix size 2412 and larger:
01 - 32 = input 1 through input 32
98 = power supplies
99 = fans
Matrix size 1616 and smaller 01 - 17 = input 1 through input 16
17 = power supply
X4%
= Notify status (for read)
34- or 17-digit number. For each digit: 0 = do not notify, 1 = notify
X4^
= DHCP
0 =1 off, 1 = on
X4&
= Port #
00 through 99 (00 = all ports)
X4*
= Baud rate
9600, 19200, 38400, 115200
X4(
= Parity
o
dd,
e
ven,
n
one,
m
ark,
s
pace (only the first letter required)
X5)
= Data bits
7, 8
X5!
= Stop bits
1, 2
X5@
= Port type
0 = RS-232
1 = RS-422
2 = RS-485
Содержание CrossPoint 450 Plus 2412 HV
Страница 4: ......
Страница 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Страница 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Страница 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Страница 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Страница 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Страница 183: ...CrossPoint MAV Matrix Switchers A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer...
Страница 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Страница 211: ...B 21 CrossPoint MAV Matrix Switchers Reference Information Button label blanks 16 button strips...
Страница 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...