Operation, cont’d
CrossPoint / MAV Matrix Switchers • Operation
3-54
Background illumination
The buttons on the front panel can be set to provide amber background
illumination at all times or the background illumination can be turned off. To
toggle the background illumination on or off, press and hold the Input 1 and
Input 2 buttons simultaneously for approximately 2 seconds (figure 3-78).
1 2 3 16
17 18 19 32
I
N
P
U
T
S
Press and
hold the Input 1 and Input 2
buttons simultaneously to toggle
background illumination mode on or off.
After approximately 2 seconds, release
the Input 1 and Input 2 buttons.
Figure 3-78 — Toggle background illumination on or off
Selecting the rear panel Remote port protocol and baud rate
N
The Remote port settings are protected when front panel
Lock
mode 2 is
selected. You can view the settings in
Lock
mode 2 but you cannot adjust them
from the front panel. See “Setting the front panel Locks (
page 3-52.
The switcher can support either RS-232 or RS-422 serial communication protocol,
and can operate at 9600, 19200, 38400, and 115200 baud rates. The settings of these
variables can be viewed and changed from the front panel.
View and configure the switcher’s serial communications settings as follows:
1
.
To enter
Serial Port Selection and Configuration
mode, simultaneously press and
hold
all
Control buttons (Enter, Preset, View, and Esc) (figure 3-79).
The flashing Control button indicates the
baud rate as follows:
Enter — 9600
Preset — 19200
View — 38400
Esc — 115200
The flashing I/O button indicates the
protocol as follows:
RGBHV/Video — RS-232
Audio — RS-422/RS-485
In this example, the port is set to RS-232 at 9600 baud.
Press and
hold the Enter, Preset,
View, and Esc buttons.
All Control buttons light with
one flashing.
Both I/O buttons light
with one flashing.
2 seconds
I / O
RGBHV AUDIO
C O N T R O L
PRESET
ENTER
ESC
VIEW
•
•
C O N T R O L
PRESET
ENTER
ESC
VIEW
Figure 3-79 — RS-232/RS-422 and baud rate display
Содержание CrossPoint 450 Plus 2412 HV
Страница 4: ......
Страница 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Страница 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Страница 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Страница 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Страница 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Страница 183: ...CrossPoint MAV Matrix Switchers A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer...
Страница 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Страница 211: ...B 21 CrossPoint MAV Matrix Switchers Reference Information Button label blanks 16 button strips...
Страница 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...