AVT 200HD Tuner • Remote Configuration and Control
58
X7&
= Event data size
b
= bit
B
= byte (8 bits)
S
= short (16 bits)
L
= long (32 bits)
NOTE:
In a write operation, this parameter can optionally be preceded by
A
(for
and
) or
O
(for
or
) to logically combine with content instead of replacing it.
X7*
= Event data to write
X7(
= Reading password
Responds with
****
if a password exists; the
response is empty if there is no password.
X8)
= Number of bytes to read
1
through
127
X8!
= E-mail event number/mailbox
1
through
64
(Response is returned as 3 digits with
leading zeros.)
X8@
= E-mail account
65
through
72
65
= email recipient 1, 66 = recipient 2, ...,
72
= recipient 8
X8#
= E-mail recipient address
Typical e-mail address format
(for example:
nnnn
@
xxx
.com
)
X8$
= Name of e-mail file to be sent
The first line of file is the subject; the rest is the body
(for
CR
command)
of the e-mail.
Numeric name of e-mail file to be Format =
nnn
.eml
.
nnn
=
1
through
999
.
sent (for
SM
command)
X8%
= Default unit name
Combination of the model name and the last three
pairs of the unit MAC address (for example,
AVT-200-HD-05-62-3D
X8*
= Security level of connection
11
= user
12
= administrator
X8(
=
Time (in 10-ms increments) to wait
1
through
32767
(
1
=10 ms;
100
= 1000 ms = 1 second)
for receive data before releasing
Default =
10
, or 100 ms
port to another source
(Response is returned with leading zeros.)
X9)
= ASCII digits representing numeric
Leading zeros are suppressed.
value of data element read from
event buffer.
X9%
= Broadcast repetition rate in seconds
0
through
255
Default =
0
(clear)
(The response is returned with leading zeros.)
X9^
= Login allowed without password
0
= disabled
1
= enabled
X9*
= No-password login level
1
–
11
= entry without password goes to the level
specified, if an administrator password exists.
0
= entry without password is placed one level below
the lowest level that has a password (to 0-11).
The response is returned as 2 digits with leading zero.
X9(
= Number of seconds before IP
1
through
65000
connection timeout
Default =
30
= 300 seconds
X10#
= Hardware (MAC) address with
the 4 most significant hex
nibbles converted into a single
16-bit decimal number.
X10$
= Hardware (MAC) address with
Can be up to 10 digits.
the 8 least significant hex
nibbles converted into a single
32-bit decimal number.