HTML Operation, cont’d
SMX System MultiMatrix Switchers • HTML Operation
6-18
EDID configuration
1
.
Select the plane that has an EDID supporting output board installed.
2
.
Click the applicable
Input number
and scroll down to the resolution and
refresh rate desired (see figure 6-17, input 7).
N
The drop down list has 41 selections, where: 15 is the default value for DVI
(1024x768 @ 60 Hz), 32 is the default value for DVI-Pro (720p), 0 = automatic,
1-8 is data stored from connected EDID monitors as reference, 9-36 are factory
fixed rates, and 37-40 are user assignable (User 1= 37, User 2 = 38, User 3 = 39,
User 4 = 40). See the EDID table on page 4-14 for the full list.
Figure 6-17 — Click in an input field to see the drop down list
3.
If using 37-40, click one of the Save Output 1 User buttons (1-4) as desired.
The DDC data is saved under the User number for recall.
4.
To save an EDID setting to a user assignable number (User #1 to 4), connect
the monitor (that you want the EDID data for) to
Output #1 only
and turn on
the monitor.
5
.
Press the desired User assigned number to save the data. The saved data can
be recalled later.