DANGER

If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord
displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your
assurance that the power cord can be used safely with the device.

GEFAHR

Falls für die Installation ein anderes Stromkabel erforderlich ist (wenn das mit dem Gerät gelieferte Kabel nicht passt), müssen
Sie sicherstellen, dass Sie ein Stromkabel mit dem Siegel einer Sicherheitsbehörde verwenden, die für die Zertifizierung von
Stromkabeln in Ihrem Land zuständig ist. Das Siegel ist Ihre Garantie, dass das Stromkabel sicher mit Ihrem Gerät verwendet
werden kann.

DANGER

Si l'installation nécessite un cordon d'alimentation autre que celui fourni avec le dispositif, assurez-vous d'utiliser un cordon
d'alimentation portant la marque de l'organisation responsable de la sécurité qui définit les normes et régulations pour les
cordons d'alimentation dans votre pays. Cette marque vous assure que vous pouvez utiliser le cordon d'alimentation avec le
dispositif en toute sécurité.

PELIGRO

Si la instalación requiere un cordón de corriente distinto al que se ha suministrado con el instrumento, verifique que usa un
cordón de corriente que venga con la marca de la agencia de seguridad que defina las regulaciones para cordones de
corriente en su país. Esta marca será su garantía de que el cordón de corriente puede ser utilizado con seguridad con el
instrumento.

DANGER

For removal of the metal cable restraint cover under the high voltage power supply inlet, remove the 2 Torx screws

GEFAHR

Um die Abdeckung für die Kabelarretierung aus Metall zu entfernen, drehen Sie die 2 Torx-Schrauben heraus.

DANGER

Pour enlever le couvercle métallique de retenue des câbles qui se trouve sous l'entrée d'alimentation à haute tension, retirez
les 2 vis Torx.

PELIGRO

Para remover la cubierta metalica de protecion debajo de la entrada de la fuente de alimentación de alta tensión, remueva los
2 tornillos Torx.

Laser dangers

DANGER

All fiber-optic interfaces use Class 1 lasers.

GEFAHR

Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1.

DANGER

Toutes les interfaces en fibre optique utilisent des lasers de classe 1.

PELIGRO

Todas las interfaces de fibra óptica utilizan láser de clase 1.

DANGER

Use only optical transceivers that are qualified by Extreme Networks, Inc. and comply with the FDA Class 1 radiation
performance requirements defined in 21 CFR Subchapter I, and with IEC 60825 and EN60825. Optical products that do
not comply with these standards might emit light that is hazardous to the eyes.

GEFAHR

Verwenden Sie nur optische Transceiver, die von Extreme Networks, Inc. zugelassen sind und die die Anforderungen gemäß
FDA Class 1 Radiation Performance Standards in 21 CFR, Unterkapitel I, sowie IEC 60825 und EN60825 erfüllen.
Optische Produkte, die diese Normen nicht erfüllen, können Strahlen aussenden, die für das menschliche Auge gefährlich
sind.

DANGER

Utilisez uniquement des émetteurs-récepteurs optiques certifiés par Extreme Networks, Inc. et conformes aux exigences sur
la puissance de rayonnement de catégorie 1 de la FDA définies au sous-chapitre 21 CFR I et à les normes IEC 60825 et
EN60825. Les produits optiques non-conformes à ces normes sont susceptibles d’émettre une lumière dangereuse pour les
yeux.

PELIGRO

Utilice sólo transceptores ópticos aprobados por Extreme Networks, Inc. y que cumplan con las normas IEC 60825 y
EN60825, y con los estándares de rendimiento Clase 1 de FDA definidos en el subcapítulo I de 21 CFR. Los productos
ópticos que no cumplan con estos estándares pueden emitir luz dañina para los ojos.

Danger Notices

ExtremeRouting SLX 9850-4 Hardware Installation Guide

9035474-02 Rev AA

157

Содержание ExtremeRouting SLX 9850-4

Страница 1: ...HARDWARE INSTALLATION GUIDE ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA June 2019...

Страница 2: ...are trademarks or registered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in this document are the property of...

Страница 3: ...al precautions 23 ESD precautions 23 Lifting precautions 24 Laser precautions 24 Facility requirements 24 Time and items required for installation 25 Quick installation checklists 26 Pre installation...

Страница 4: ...nitoring Overview 75 Interpreting management module LEDs 75 Interpreting interface module LEDs 77 Interpreting power supply module LEDs 80 Interpreting fan module LEDs 83 Interpreting switch fabric mo...

Страница 5: ...h Fabric Modules 119 Switch fabric module overview 119 Precautions specific to the switch fabric module 120 Time and items required for replacement 121 Removing a switch fabric module 121 Inserting a...

Страница 6: ...C 144 Regulatory compliance safety 144 Regulatory compliance environmental 144 Regulatory Statements 147 BSMI statement Taiwan 147 Canadian requirements 147 CE statement 147 China ROHS 148 FCC warning...

Страница 7: ...n traffic might be interrupted or the device might reboot CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware firmware software or...

Страница 8: ...and examples If a backslash separates two lines of a command input enter the entire command at the prompt without the backslash Documentation and Training To find Extreme Networks product guides visit...

Страница 9: ...ns You can subscribe to email notifications for product and software release announcements Vulnerability Notices and Service Notifications 1 Go to www extremenetworks com support service notification...

Страница 10: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 10 9035474 02 Rev AA...

Страница 11: ...OS 16r 1 00 Yes TABLE 2 SLX 9850 4chassis bundles Part number Long description Introduced OS Currently supported BR SLX9850 4 BND AC SLX 9850 4 slot chassis with 1 management module 5 switch fabric m...

Страница 12: ...re versions specified below Auto Level Support Table 1 Auto Level Support 32 bit Linecard LC 64 bit Linecard LC 17r 101a or lower 17r 1 01b 17r 2 00 or higher 32 bit Mgmt Module MM 17r 101a or lower S...

Страница 13: ...pports 750K MAC 256K IPv4 64K IPv6 routes SLX OS 16r 1 01 Yes BR SLX9850 100Gx36CQ M SLX 9850 36 port 100 GbE 60 port 40 GbE or 240 port 10 GbE flex speed M interface module with IPv4 IPv6 MPLS hardwa...

Страница 14: ...le 10m 1 pack SLX OS 16r 1 00 Yes 40G QSFP QSFP C 0101 4x10GE Direct Attached QSFP to 4 SFP Active Copper Breakout Cable 1m 1 pack SLX OS 16r 1 00 Yes 40G QSFP 4SFP C 0301 4x10GE Direct Attached QSFP...

Страница 15: ...uld only be connected to an E1MG BXU at the far end SLX OS 16r 1 00 Yes E1MG BXU 1000Base BXU SFP optic SMF transmits at 1310nm and receives at 1490nm LC connector single strand SMF fiber This optic s...

Страница 16: ...post rack mounting kit for 4 slot chassis Includes Telco flush and midplane mounting TABLE 13 SLX 9850 4 cable management kit Part number Long description XBR SLX9850 4 CAB SLX 9850 Cable Management...

Страница 17: ...e is located at the top of the chassis The following figure shows the device slot numbering and port side view of the SLX 9850 4 The call outs in the figure correspond to the numbering of each router...

Страница 18: ...pply slot 2 9 Power supply slot 3 10 Power supply slot 4 11 Power supply slot 5 12 Power supply slot 6 Device slot numbering nonport side The following figure shows the nonport side view of the SLX 98...

Страница 19: ...abric modules are located behind the fans There are six slots for the switch fabric modules Numbering for the modules goes from left to right with 1 on the far left and 6 on the far right Device slot...

Страница 20: ...6 Device management options Use the serial ports to manage your device The serial ports are located on the management module The following figure shows the serial console ports Use the console port fo...

Страница 21: ...1 Service Ethernet port 10G 1G 100M 2 Auxiliary console port 3 USB port 4 USB port 5 Console port 6 Management Ethernet port 1G 100M 10M Device management options ExtremeRouting SLX 9850 4 Hardware I...

Страница 22: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 22 9035474 02 Rev AA...

Страница 23: ...re beginning the installation see the precautions in Power precautions CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for compliance coul...

Страница 24: ...ions on page 137 Electrical Ensure that there are dedicated electrical branch circuits with the following characteristics Protected by a circuit breaker in accordance with local electrical codes Suppl...

Страница 25: ...your device fully populated with the required interface modules refer to the ExtremeRouting SLX 9850 Technical Specifications on page 137 Installing rack mount kit 30 minutes Refer to instructions in...

Страница 26: ...tiple devices TABLE 16 Installation prerequisites Task Task details or additional information Completed Unpack the device Unpack the device as shown in the Unpacking the shipping carton on page 28 Tak...

Страница 27: ...the chassis virtual ip or chassis virtual ipv6 command to configure an IP address For more information refer to Configuring a static IP address on page 66 Establish an Ethernet connection By establis...

Страница 28: ...install your device The device is packaged in a cardboard box with foam packing on a wooden pallet 1 Cut the bands that encircle the packing carton a Unpack the device b Leave the device on top of th...

Страница 29: ...ules are packaged separately while the switch fabric modules are shipped inside the chassis Packing foam Antistatic plastic An accessory kit containing the following items A serial cable ESD wrist str...

Страница 30: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 30 9035474 02 Rev AA...

Страница 31: ...eview the Safety Precautions before mounting the device Mounting safety precautions The following precautions specifically apply to mounting the device DANGER Mount the devices you install in a rack a...

Страница 32: ...find the weight of your device fully populated with the required interface modules refer to the ExtremeRouting SLX 9850 Technical Specifications on page 137 Device surface preparation All surfaces on...

Страница 33: ...ght rail assembly 1 5 Screw 8 32 x 312 in flathead 6 Screw M6x1 0x12 in square cone 7 Screw 10 32 x 63 in square cone 8 Screw 8 32 x 375 in patch lock 9 Nut retainer 10 Washer 11 Nut clip floating Ins...

Страница 34: ...post rack has rectangular unthreaded holes use 16 screws 16 nuts and 16 alignment washers from the rack mount kit to attach the kit to the posts 2 Prepare the device for mounting by attaching the lif...

Страница 35: ...it in the four post rack ensuring that it remains supported during the transfer FIGURE 6 Installing the two rails from the rack mount kit Installing a device on a four post rack ExtremeRouting SLX 985...

Страница 36: ...FIGURE 7 Installing the rack mount kit to the four post rack Installing a device on a four post rack ExtremeRouting SLX 9850 4 Hardware Installation Guide 36 9035474 02 Rev AA...

Страница 37: ...ates from the recessed mount kit 1 Install the two rails from the rack mount kit for the four post rack with the rails perpendicular to the aisle 16 fasteners are required 4 for each post If the four...

Страница 38: ...nting by attaching the lift to the device chassis 5 Using the lift raise the device to the correct level 6 If applicable lock the wheels of the lift 7 Ensure that the device is oriented so that the fr...

Страница 39: ...ric modules interface modules switch fabric modules fan modules and power supply modules that have not already been installed Installing a device on a two post rack Use part number XBR SLX9850 4 2PRM...

Страница 40: ...1 Left ear bracket 2 Right ear bracket 3 Saddle 4 Screw 8 32 x 312 in flathead 5 Screw 10 32 x 63 in square cone 6 Nut retainer Installing a device on a two post rack ExtremeRouting SLX 9850 4 Hardwar...

Страница 41: ...t washers from the rack mount kit to attach the saddle to the posts FIGURE 12 Installing the saddle onto the two post rack 2 Remove the two side plates on the front port side of the chassis 3 Attach t...

Страница 42: ...device until it rests on the saddles 9 Attach the device to the two posts of the rack using 6 screws 3 on each side FIGURE 13 Attaching the device to the rack 10 Install any device modules management...

Страница 43: ...ount kit to attach the saddles to the posts 2 Remove the two side plates on the front port side of the chassis 3 Attach the larger side plates from the mid mount kit using 16 screws 8 per side FIGURE...

Страница 44: ...pply modules that have not already been installed Installing an SLX 9850 4 NEBS kit Use the following instructions to install the SLX 9850 NEBS two post rack kit with a mid mount Use this kit XBR SLX9...

Страница 45: ...e comb assembly 1 3 Air filter 1 4 Chassis door 1 5 Velcro strap 8 6 Screw 10 32 x 63 in square cone washer 10 7 Screw 8 32 x 312 in flathead 20 8 Nut retainer 6 Installing an SLX 9850 4 NEBS kit Extr...

Страница 46: ...ting the NEBS kit installation the bezel needs to be removed FIGURE 17 Chassis installed on 2 post mid mount rack with bezel Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Instal...

Страница 47: ...t holds the bezel to be removed prior to starting NEBS kit installation FIGURE 18 Bezel screws to be removed 1 Screw Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation G...

Страница 48: ...3 Remove the 6 screws FIGURE 19 Removing the screws holding the bezel Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 48 9035474 02 Rev AA...

Страница 49: ...ate the position where the six ball studs will be installed FIGURE 20 Ball studs to be installed Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev...

Страница 50: ...tall the 6 ball studs using a 1 4 Hex socket driver FIGURE 21 Ball studs installed 1 Ball studs Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 50 9035474 02 Re...

Страница 51: ...e left cable comb assembly and the right cable comb assembly FIGURE 22 Installing cable comb assemblies Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474...

Страница 52: ...ent washers from the rack mount kit to attach the cable combs to the posts FIGURE 23 Cable comb assemblies installed 1 Screw Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Instal...

Страница 53: ...8 Snap the door onto chassis ball studs FIGURE 24 Installing the chassis door Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA 53...

Страница 54: ...ble management combs You can install the cable management combs shipped with the chassis without service interruption for simple cable management If installing cable management combs remove the chassi...

Страница 55: ...4 chassis For more information about cable management refer to the Managing cables on page 127 under the Transceivers and cables section of this guide Installing cable management combs ExtremeRouting...

Страница 56: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 56 9035474 02 Rev AA...

Страница 57: ...lish an Ethernet connection By establishing an Ethernet connection you can complete the device configuration using a serial or Telnet session Refer to Establishing an Ethernet connection on page 68 fo...

Страница 58: ...vice The device mounted and installed with the required interface modules FRUs transceivers and cables and connected to a power source A workstation computer with an installed terminal emulator applic...

Страница 59: ...C cord to the power supply module complete the following steps 1 Attach the chassis ground lug to the chassis ground 1 Chassis ground lug Providing power to the device ExtremeRouting SLX 9850 4 Hardwa...

Страница 60: ...upply 1 Power supply receptacle 3 Route the cable so it will be out of the way when connected to the power source 4 Plug the other end of the cable into the power source Providing power to the device...

Страница 61: ...1 50 shrink ratio Nominal recommended wall thickness 30480 mm 012 in minimum Dielectric strength 800V mil Tensile strength Greater than or equal to 5000 psi Operating temperature 40 C to 150 C 40 F t...

Страница 62: ...eat shrink tubing 2 Power lug 9 Connect the power lugs to the power supply module Connect the 48V wire to the negative terminal and the 0V wire to the positive terminal NOTE The DC return must be isol...

Страница 63: ...on the enclosure Before crimping the ground wire into the provided ground lug ensure the bare copper wire has been cleaned and antioxidant is applied to the bare wire To ensure adequate bonding when...

Страница 64: ...0M 2 Auxiliary console port 3 USB port 4 USB port 5 Console port 6 Management Ethernet port 1G 100M 10M NOTE The console or serial port is intended primarily for the initial setting of the IP address...

Страница 65: ...asswords for switch default accounts now Use Control C to exit or press Enter key to proceed 7 Press Enter to step through a procedure to change the passwords as shown in the following example To skip...

Страница 66: ...ddress dhcp device config Management 1 ip address 10 24 85 81 20 5 Return to privileged EXEC mode by entering exit device config exit device 6 To display the configuration use the show running config...

Страница 67: ...Time 23 08 49 GMT SLX OS Version 17r 1 00 Jumbo Capable yes Burned In MAC MM1 60 9c 9f 46 e2 06 MM2 60 9c 9f 47 10 7a Management IP 10 25 101 4 Management Port Status UP The MAC addresses are used to...

Страница 68: ...0 0000 0000 0000 0000 Remove the host portion of the address based on a 64 netmask 2001 0DB8 0000 0000 Contract the remaining portion of the address of any leading zeros 2001 DB8 f Combine the IPv6 ne...

Страница 69: ...g in to the device through a Telnet or SSH session using the chassis management IP address and admin login Customizing the chassis and host names To configure a chassis and host name complete the foll...

Страница 70: ...uminated in blue A Telnet session using the chassis management IP address 2 Log in to the device using admin as your login name If you have not changed the default password use password for password 3...

Страница 71: ...work current it is recommended that each device has its time synchronized with at least one external NTP server The device maintains the current clock server value in nonvolatile memory By default thi...

Страница 72: ...onfig clock timezone America Los_Angeles Verifying correct operation Perform the following steps to verify correct operation of the device 1 Check the LEDs of all power supplies fans and modules to ve...

Страница 73: ...ice using one of the following methods A serial console connection to the active management module The active management module has the LED labeled ACTIVE on the front panel illuminated in blue A comm...

Страница 74: ...oad command are blocked on this device until the device is rebooted The device also informs its HA peer to shut down its database gracefully and not handle any database requests moving forward The dev...

Страница 75: ...ption of the operations that the device performs when you power it on The following commands can be especially helpful in monitoring the health status of various device components For details about th...

Страница 76: ...the show slots command If the LED remains amber consult the device supplier Green Module is powered on No action is required Power No light LED is off Module is not powered on Ensure that the module...

Страница 77: ...gh port No action is required No light LED is off Port has no incoming power or there is no light or signal carrier detected Verify that the power LED is on Check the transceiver and cable Connected d...

Страница 78: ...three rows of Ethernet ports FIGURE 35 Interface module port LEDs used for the 72 port 10GbE 1GbE interface module and similar for the other half of the flex speed interface module ports 1 LED for th...

Страница 79: ...r on linecard slot_number command to make sure that the module is powered on in software Amber Module is faulty or initializing Check the module status by entering the show slots command If the LED re...

Страница 80: ...required Green steadily blinking on and off for two seconds at a time A local fault has been detected Local fault detection can be confirmed with CLI flex cli show local fault To clear LED in this st...

Страница 81: ...FIGURE 37 AC Power supply module LEDs 1 LED 1 AC in good 2 LED 2 AC out good Interpreting power supply module LEDs ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA 81...

Страница 82: ...t the power supply is firmly seated the power cable is connected and that the power cable is connected to a power source Disconnect the power cable from the power supply remove and reinsert the power...

Страница 83: ...D Top LED power Bottom LED status NOTE There are two sets of LEDs one for the fan and one for the switch fabric module SFM This table describes both sets of LEDs TABLE 23 Fan module LED descriptions L...

Страница 84: ...ing the show slots command If LED remains amber consult the device supplier Green Module is operational No action is required Interpreting switch fabric module LEDs Refer to the following illustration...

Страница 85: ...s powered off it does not indicate a problem on the device TABLE 24 SFM LED descriptions LED purpose Color Status Recommended action Power No light LED is off Module is not powered on Ensure that the...

Страница 86: ...re tightened Amber Module is faulty or initializing Check the module status by entering the show slots command If LED remains amber consult the device supplier Green Module is operational No action is...

Страница 87: ...t management module works in conjunction with the active management module If the active module becomes unavailable the redundant management module automatically takes over the system operation minimi...

Страница 88: ...other electronic devices To avoid damage keep static sensitive devices in their static protective packages until you are ready to install them CAUTION The 1GbE Management Port is suitable for connecti...

Страница 89: ...FIGURE 42 ESD ground strap chassis connection front 1 ESD ground strap connection point ESD ground strap connection points ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA 89...

Страница 90: ...replacement procedure for the management module takes approximately 30 minutes The following items are required for the management module replacement ESD grounding strap Workstation or laptop compute...

Страница 91: ...dule is being replaced if the redundant management module is installed and initialized Complete the following steps to remove a management module Refer to the illustration provided with the procedure...

Страница 92: ...ment module Refer to Precautions specific to the management modules on page 88 before replacing a management module Complete the following steps to insert a management module Refer to the illustration...

Страница 93: ...wer and is firmly seated and that the ejectors are in the locked position 10 Reconnect any cables that were attached to the old module Verifying management module operation To verify proper operation...

Страница 94: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 94 9035474 02 Rev AA...

Страница 95: ...erface modules supported for the SLX 9850 36 port 100GbE 60 port 40GbE or 240 port 10GbE flex speed interface module 72 port 10GbE 1GbE interface module The following figure shows the front panel of t...

Страница 96: ...turn off the blinking LEDs enter the chassis beacon disable command FIGURE 47 Port numbering for the flex speed module when port speed is set to 100GbE The following figure shows the front panel of th...

Страница 97: ...tion from dust The line cards are sensitive to electrostatic discharge ESD When working with any Extreme module use correct electrostatic discharge ESD procedures Wear a wrist grounding strap connecte...

Страница 98: ...f multiple line cards in chassis slots it is recommended to install the blades from the bottom to the top Using this procedure the last blade to be installed would be LC 1 NOTE When handling or liftin...

Страница 99: ...e module in the slot 9 Tighten the captive screws using the 2 Phillips screwdriver NOTE The interface module will not function unless the captive screws are tightened 10 Install the transceivers and c...

Страница 100: ...iginal interface module from the chassis database by following these steps a Enter the configure terminal command to enter global configuration mode b Enter the no linecard slot_number command This co...

Страница 101: ...rpreting interface module LEDs on page 77 2 Enter the following commands and note any error conditions show linecard Displays the current status of each interface module show system Displays informati...

Страница 102: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 102 9035474 02 Rev AA...

Страница 103: ...ing replacement if procedures are followed in this guide NOTE Depending on the module configuration of the chassis and the number of power supplies installed the device may be able to continue operati...

Страница 104: ...LED 2 DC Out LED 3 AC power cable receptacle 4 Handle 5 Securing latch The following figure shows the components of the DC power supply Power supply module overview ExtremeRouting SLX 9850 4 Hardware...

Страница 105: ...AC and DC power supplies and High Voltage AC and High Voltage DC PSU refer to ExtremeRouting SLX 9850 Technical Specifications on page 137 Power cables are not supplied with the SLX 9850 devices Powe...

Страница 106: ...eplacement procedure for each power supply takes less than 5 minutes The following items are required for the power supply replacement New power supply unit or filler panel 2 Phillips screwdriver Remo...

Страница 107: ...URE 53 AC power supply 1 Power supply AC connector 3 Lift the latch on the lower part of the power supply to release the power supply from the chassis Removing an AC power supply module ExtremeRouting...

Страница 108: ...to the illustration provided with the procedure 1 Unpack the new power supply and remove it from the anti static bag 2 Inspect the power supply for damage 3 Insert the power supply into the slot 4 Ma...

Страница 109: ...the power lugs FIGURE 55 DC power supply lugs 1 Power lug 2 Power lug 4 Depress the latch on the lower part of the power supply to release the power supply from the chassis 5 Grasp the handle and pull...

Страница 110: ...tatus of the power supply show system Displays information of each component in the system High Voltage Power Supply Unit supporting AC and DC Voltages The SLX 9850 4 supports High Voltage Power Suppl...

Страница 111: ...LED for status indication of PSU The table below indicates the status LED color and their meaning TABLE 27 HV PSU Status LED Definitions Type LED Definitions Power supply LEDs LED 1 and LED 2 Steady G...

Страница 112: ...n Power Products as described in the connector type section High Voltage input power is provided to the chassis by means of up to 6 detachable power cords for F4 and up to 12 detachable line cords for...

Страница 113: ...s not supported NOTE HV PSUs will be supported only on build to order base chassis SKU namely Fusion Chassis P Ns These offerings do not include PSUs or Fans PSUs and Fans must be added based on the c...

Страница 114: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 114 9035474 02 Rev AA...

Страница 115: ...over temperature condition it automatically sends a warning message When the critical temperature is reached the system shuts down NOTE The ambient intake temperature of the system must be less than 3...

Страница 116: ...lt LEDs should be unlit 2 Use the screwdriver to loosen the four captive screws at the top and bottom of the fan NOTE The fan needs to be replaced within 2 minutes if the ambient temperature exceeds 3...

Страница 117: ...ror conditions Air filter replacement schedule The air filter is only used with systems that include a NEBS kit for NEBS compliance You can remove and replace an air filter when it gets too clogged wi...

Страница 118: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 118 9035474 02 Rev AA...

Страница 119: ...ely fail If an SFM fails the SFM LED on the management module and fan module displays amber showing which SFM has failed and a syslog message is created System traffic is automatically is re balanced...

Страница 120: ...nt intake temperature of the system must be less than 35 deg C 95 deg F at sea level to prevent overheating If the ambient temperature is greater than 35 deg C the module installation time must be red...

Страница 121: ...o be removed by performing one or both of the following steps Refer to the sticker on the rear of the chassis below the fans that provides a graphic representation of the SFMs behind each fan module F...

Страница 122: ...placed within 2 minutes if the ambient temperature exceeds 35 deg C 95 deg F Inserting a switch fabric module Complete the following steps to insert the switch fabric module SFM similar to the procedu...

Страница 123: ...r to insure the ejector is held in the closed position the user may need to hold the ejector down by hand during operation or turning the thumbscrew NOTE The SFM will not function unless the captive s...

Страница 124: ...k SFM status For information about interpreting LED patterns refer to Interpreting switch fabric module LEDs on page 84 2 Enter the following commands and note any error conditions show chassis show s...

Страница 125: ...current information about transceivers and cables that is supported by this ExtremeRouting SLX 9850 device refer to the Extreme Ethernet Optics Family Datasheet on https cloud kapostcontent net pub a...

Страница 126: ...ION Before plugging a cable into any port be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface Cleaning the fiber optic connectors To avoid proble...

Страница 127: ...y from the LEDs Do not route the cables in front of air vents Use Velcro type straps to secure and organize fiber optic cables Route the cables away from LEDs to keep them visible Use the cable manage...

Страница 128: ...ing mechanism clicks FIGURE 62 Installing an SFP transceiver with pull tab into the interface module port 1 Pull tab 2 Transceiver If the transceiver uses a bail latch mechanism 10 GbE transceivers on...

Страница 129: ...ceiver until the latching mechanism clicks NOTE Cables are keyed so that they can be inserted in only one way If a cable does not slide in easily ensure that it is correctly oriented Do not insert any...

Страница 130: ...tly using the bail and then gasp the transceiver with your fingers and slide it straight out of the port FIGURE 64 Installing an SFP transceiver with bail latch into the interface module port 1 Bail I...

Страница 131: ...igned with the slot in the transceiver Insert the cable into the transceiver until the latching mechanism clicks Cables are keyed so that they can be inserted in only one way If a cable does not slide...

Страница 132: ...Rapid flash link with traffic Slow flash one second on one second off beaconing feature 2 Position the cable so that the key the ridge on one side of the cable connector is aligned with the slot in t...

Страница 133: ...ng the transceiver body 3 To insert the replacement transceiver use the pull tab to carefully push the transceiver into the port Transceivers are keyed so that they can only be inserted with the corre...

Страница 134: ...R4 INT and 40G QSFP ESR4 optics for use with fiber breakout cables The copper breakout cables are terminated with optical connectors and are available in 1m 3m 5m and greater lengths No additional con...

Страница 135: ...n also replace the following hardware components as needed All modules management interface and switch fabric modules Fiber optic transceivers AC power supply modules AC or DC power supply modules Fan...

Страница 136: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 136 9035474 02 Rev AA...

Страница 137: ...le 8 maximum Switch fabric module SFM 6 maximum Management modules MM 2 maximum Power supply assemblies 12 maximum Fan assemblies 3 maximum Power inlet C20 power from port side Power supplies SLX 9850...

Страница 138: ...ch fabric module OK Amber error Off Unexpected error Ethernet Green Solid Link is up Green Blinking Link is up and running traffic Off No link Amber some flex module ports module is in 100G mode and t...

Страница 139: ...including two management modules six switch fabric modules three fans four power supplies and two cable management combs Model Height Width Depth Weight empty Weight fully loaded SLX 9850 4 10 rack un...

Страница 140: ...terface module part number BR SLX9850 100Gx3 6CQ M Interface module with 36 100GbE ports requires QSFP28 optics 40GbE ports requires QSFP optics or 240 10GbE ports requires 40GbE to 10GbE breakout 64...

Страница 141: ...e cards are enabled and optics Traffic are at 50 line rate Random packets fans at nominal speed ambient temperature 25 deg C Configuration of SLX 9850 8 One 8 slot chassis with one management module f...

Страница 142: ...amps watts and BTU hr are calculated with 0 98 power factor and 4 PSUs Power consumption modules typical configuration NOTE Typical configuration is 50 traffic with fans operating normally Ambient te...

Страница 143: ...40GbE or 240 port 10GbE flex speed interface modules SLX 9850 8 1 GbE 576 Supports up to 576 1 GbE ports with eight 72 port 10GbE 1GbE interface modules 10 GbE 576 Supports up to 576 1 GbE ports with...

Страница 144: ...mark Immunity for Information Technology Equipment ICES 003 Canada Class A AS NZ 55022 Australia Class A VCCI Japan Class A EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 Regulatory compliance safety CAN CSA...

Страница 145: ...n and Restriction of Chemicals EU REACH Section 1502 of the Dodd Frank Wall Street Reform and Consumer Protection Act of 2010 U S Conflict Minerals 30 2011 TT BCT Vietnam circular SJ T 11363 2006 Requ...

Страница 146: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 146 9035474 02 Rev AA...

Страница 147: ...of the Canadian Interference Causing Equipment Regulations ICES 003 Class A Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CE statement ATTENTION This is a Class A produ...

Страница 148: ...nstruction manual might cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be requ...

Страница 149: ...is used in a domestic environment radio disturbance might arise When such trouble occurs the user might be required to take corrective actions Japan power cord English translation of above statement A...

Страница 150: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 150 9035474 02 Rev AA...

Страница 151: ...ment PRECAUCI N Si se realizan cambios o modificaciones en este dispositivo sin la autorizaci n expresa de la parte responsable del cumplimiento de las normas la licencia del usuario para operar este...

Страница 152: ...und wire should have an agency approved crimped connector provided with the device attached to one end with the other end attached to building ground The connector must be crimped with the proper tool...

Страница 153: ...sa ubicaci n CAUTION All devices with DC power supplies are intended for installation in restricted access areas only A restricted access area is a location where access can be gained only by trained...

Страница 154: ...use the port cover tabs to lift the module They are not designed to support the weight of the module which can fall and be damaged VORSICHT Verwenden Sie nicht die Laschen der Anschlussabdeckungen um...

Страница 155: ...a DANGER Do not attempt to lift the Extreme Networks chassis It is extremely heavy Use a mechanical lifting device to lift the chassis Four or more people are required to position the unpopulated chas...

Страница 156: ...das las fuentes de corriente DANGER High Touch Current Earth connection essential before connecting supply GEFAHR Hoher Ableitstrom Vor Anschluss ans Netz Schutzerdung herstellen DANGER Courant de fui...

Страница 157: ...ique de retenue des c bles qui se trouve sous l entr e d alimentation haute tension retirez les 2 vis Torx PELIGRO Para remover la cubierta metalica de protecion debajo de la entrada de la fuente de a...

Страница 158: ...n in den Laserstrahl herein Klasse 1M Laserprodukte DANGER Rayonnement de laser Ne regardez pas directement avec des instruments optiques Produits de laser de classe 1M PELIGRO Radiacion de Laser No v...

Отзывы: