1

2

3

4

5

6

1

4

3

2

5

6

19

ENGLISH

General menu

go back - exit 

    scroll parameters: next (3); previous (2)

    

    Change settings data: increase (4); decrease (5)

Confirm - access menu

General warnInGs

advice to follow for the first start-ups of the product:

During the first hours of operation, there may be some smoke or 

odours, but they are due to the normal “thermal break-in” process.

During this process, the duration of which changes depending on 

the product, it is recommended to:

 

Š

Ventilate the room well

 

Š

if present, remove any majolica or natural stone parts from the 

top part of the product

 

Š

activate the product at the maximum power and temperature

 

Š

avoid remaining in the room for a long time

 

Š

Do not touch the surfaces of the product

Notes: 

The process is completed after a few heating/cooling cycles.

For combustion, do not use elements or substances other than those 

indicated in the manual.

Before turning on the product, it is necessary to perform the 

following checks:

 

Š

if it is intended to be connected to a hydraulic system, it must 

be complete and fully functional and in compliance with the 

instructions given in the product manual and with the relevant 

regulations in force.

 

Š

The pellet hopper must be fully loaded

 

Š

The combustion chamber and the burn pot must be clean

 

Š

make sure that the fire holder, the ash drawer and the pellet 

hopper close hermetically (if present in the hermetic version); they 

must be closed and there must be no foreign bodies in the sealing 

elements and gaskets.

 

Š

Check that the power cord is properly connected

 

Š

The bipolar switch (if present) must be set to position “1”.

VENtiLatiON

ENaBLiNG

SPEED

EaSY SEtUP

SEt

SEt thERMOStat

chRONO

ENaBLiNG

PRG1

PRG2

SEttiNGS

DatE-tiME

PRG3

LaNGUaGE

PRG4

 

DiSPLaY

StaND BY

FiRSt LOaD

OUtLEt aiR

cLEaNiNG

*StOVE StatUS

DEGREES

*

TeCHNiCiaNs ONLY

RESEt

*tEch MENU

EaSY cONtROL

**SYStEM SEt

DEPRESSURE NOticE

**SYStEM Stat

**wiTH sYsTem exPaNsiON BOarD ONLY (OPTiONaL)

DO NOt USE aNY tYPE OF FLaMMaBLE LiQUiDS FOR iGNitiON!
DO NOt aLLOW thE BaG OF PELLEtS tO cOME iNtO cONtact With thE BOiLiNG hOt StOVE DURiNG thE FiLLiNG 
PhaSE!
iN thE EVENt OF cONtiNUED FaiLURE tO LiGht, cONtact aN aUthORiSED tEchNiciaN.

Содержание GUENDA IDRO

Страница 1: ...MADE IN ITALY design production GUENDA IDRO 004280684 rev 000 ENGLISH UK THERMO PRODUCTS USER MANUAL...

Страница 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL...

Страница 3: ...thermostat operation with STAND BY active 22 Additional thermostat operation with STAND BY deactivated 22 ADDITIONAL THERMOSTAT INSTALLATION 22 VENTILATION 23 EASY SETUP 23 CHRONO 24 ENABLING DISABLIN...

Страница 4: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Страница 5: ...IF IT IS DISCONNECTED FROMTHE MAINS It is advised to position the power supply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible afte...

Страница 6: ...clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Страница 7: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Страница 8: ...always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be prov...

Страница 9: ...houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combustion air must be directly connected to th...

Страница 10: ...and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these instructions For Italy installation mus...

Страница 11: ...This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre existing flues is re...

Страница 12: ...safety drain T2 Boiler flow output T3 Boiler return input Combustive air input Room air outlet Pellet hopper Heat exchanger scrapers Door handle Fumes exhaust Not used fuse Power supply 230v On Off He...

Страница 13: ...veying motor and therefore operation of the heat generator The system must be bled several times to eliminate the air and loaded when the pressure is too low It is not an anomaly but normal phenomenon...

Страница 14: ...ion means that you have 60 to close the hatch door and the pellet lid If this is not the case during ignition the stove will go to DEPRESSION ALARM mode while during normal operation the stove will go...

Страница 15: ...LITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND CAN VOID THE WARRANTY AND THE ANNEXED RESPONSIBILITY OF THE MANUFACTURER Pellet tank During the operation of the stove the...

Страница 16: ...On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the switch off delay F...

Страница 17: ...Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight or near a sour...

Страница 18: ...external additional thermostat Closed contact the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open WI FI BT STBY OK ON STA...

Страница 19: ...ed to be connected to a hydraulic system it must be complete and fully functional and in compliance with the instructions given in the product manual and with the relevant regulations in force The pel...

Страница 20: ...and confirm by pressing key 6 Select the language using keys 4 or 5 Press key 6 to confirm and key 1 to scroll back through the menus until the initial page DEGREES This menu allows you to set the un...

Страница 21: ...s of the room temperature probe integrated in the product see the chapter VENTILATION on the following pages BLOW During the working phase the stove has an internal timer which after a pre set period...

Страница 22: ...the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat operation with...

Страница 23: ...e keys 4 5 to set the range Press key 6 to confirm and key 1 to scroll back through the menus until the initial page N B IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN PO...

Страница 24: ...s and confirm by pressing key 6 Confirm ENABLING by pressing 6 Use keys 4 5 to enable ON or disable OFF Press key 6 to confirm and key 1 to scroll back through the menus until the initial page J If we...

Страница 25: ...t 3 1 02 00 23 00 08 00 16 30 t 72 68 2 1 25 ENGLISH Time slot 1 Start 02 00 Stop 23 00 Power 3 SET H2O 72 C Time slot 2 Start 08 00 Stop 16 30 Power 1 SET H2O 68 C Stove operation TIME SLOT SET POWE...

Страница 26: ...ressing key 3 until STAND BY appears and confirm by pressing key 6 Use keys 4 5 to enable ON disable OFF Press 1 several times to confirm and exit the menu FIRST LOAD This function allows the auger to...

Страница 27: ...key 6 Use keys 4 5 to enable ON disable OFF Press key 1 several times to confirm and exit the menu EASY CONTROL The function allows for two values to be set OFF disabled factory default ON enabled Act...

Страница 28: ...pressed the message KEYS LOCKED will appear To lock the keypad press keys 1 and 5 simultaneously until the following message appears KEYS LOCKED To unlock the keypad press keys 1 and 5 simultaneously...

Страница 29: ...e the warranty CLEANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic g...

Страница 30: ...ng it at the back A Clean the combustion chamber and the bottom of the burn pot completely using a suitable vacuum cleaner Refit the ash conveyor by performing the same operation in reverse Always mak...

Страница 31: ...s to be vacuumed and cleaned If there are horizontal sections the residue must be removed to prevent it from obstructing the flow of fumes SHUT DOWN END OF SEASON At the end of each season before turn...

Страница 32: ...and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning E Check air intake pipe a...

Страница 33: ...only if the generator has been in an OFF state for at least 96 hours the pump is activated for the time pre set by the manufacturer in order to prevent it from blocking AUTO BLOW The automatic blow is...

Страница 34: ...ER CONTROL ALARM Abnormal pellet feeding Contact after sales centre AUGER BLOCKED Abnormal operation of pellet motor Contact after sales centre TRAPDOOR BLOCKED The automatic cleaning of the burn pot...

Страница 35: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Страница 36: ...0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufactu...

Отзывы: