23
ENGLISH
EaSY SEtUP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering pellet
quality. By using the easY seTUP function, it is possible to change the calibration of the volumetric weight by increasing or decreasing the
preset values.
in the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value, which is 0.
if you notice an excessive deposit in the burn pot, access the easY seTUP program and lower the value by one unit to “- 1”; then wait until the
next day and if there is no improvement, decrease again, to a maximum of “- 3”.
instead, if it is necessary to increase the calibration of the volumetric weight of the pellet, change the factory value from “0” to “+ 1, + 2, + 3” as
required.
EXcESSiVE PELLEt DEPOSit iN BURN POt
NORMaL OPERatiON
MiNiMUM PELLEt DEPOSit iN BURN POt
-3
-2
-1
0
+1
+2
+3
THirD
DeCrease
raNge iF THe
FirsT TwO are
iNsUFFiCieNT
seCOND
DeCrease
raNge iF
THe FirsT is
iNsUFFiCieNT
FirsT DeCrease
raNge (TesT
FOr 1 DaY)
OPTimaL FaCTOrY
VaLUe
FirsT iNCrease
raNge
seCOND
iNCrease
raNge iF
THe FirsT is
iNsUFFiCieNT
THirD iNCrease
raNge iF THe
FirsT TwO are
iNsUFFiCieNT
CONTrOLs PrOCeDUre
Press key 6.
Press key 3 until
EaSY SEtUP
appears and confirm by pressing key 6.
Use keys 4 -5 to set the range.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
N.B.: iF thESE aDjUStMENtS DO NOt SOLVE thE PROBLEM OF PELLEt DEPOSitS iN thE BURN POt, PLEaSE cONtact YOUR LOcaL
SERVicE cENtRE.
ventIlatIon
This menu allows to enable or disable the operation of the tangential motor and to adjust the speed (-2, -1, 0, +1, +2) of the front fan. The
SEt
thERMOStat
allows to set the room temperature to be reached (front ventilation must be active).
Once the temperature set in
SEt tEMPERatURE
has been reached, the ventilation will turn OFF and then it will turn back on when required.
range: 07 - 37°C.
eNaBLiNg CONTrOLs PrOCeDUre
Press key 6.
Press 3 until
VENtiLatiON
appears and confirm by pressing key 6.
Confirm eNaBLiNg by pressing 6.
Use keys 4 -5 to enable (
ON
) or disable (
OFF
) and confirm by pressing 6.
Press 1 to return to the previous menus to the initial state.
sPeeD CONTrOLs PrOCeDUre
Press key 6.
Press 3 until
VENtiLatiON
appears and confirm by pressing key 6.
Press key 3 until
SPEED
appears and confirm by pressing key 6.
Use keys 4 -5 to adjust the speed (-2, -1, 0, +1, +2) and confirm by pressing 6.
Press 1 to return to the previous menus to the initial state.
seT THermOsTaT CONTrOLs PrOCeDUre
Press key 6.
Press 3 until
VENtiLatiON
appears and confirm by pressing key 6.
Keep pressing 3 until
SEt thERMOStat
appears and confirm by pressing 6.
Use keys 4 5 to adjust the room temperature (7°C - 37°C) and confirm by pressing 6.
Press 1 to return to the previous menus to the initial state.