background image

31

ENGLISH

1.

 Extraflame S.p.A. products are guaranteed, within the European community, for 24 months from the date of purchase. 

Purchase has to be proved by means of a valid fiscal document issued by the seller (receipt, invoice or shipment document) identifying the 

purchased product and its purchase and/or delivery date. 

Warning: This conventional guarantee does not replace the guarantee regulated by the European legislation on consumer rights.

The conventional guarantee is only applicable to the Italian region and to those areas, within the European Community, where the Authorised 

Technical Assistance Centres are active (see the www.lanordica-extraflame.com website)

It is also limited to the state of residence of the consumer, which must coincide with the premises and/or registered office of the seller of the 

Extraflame S.p.A. product 

These regulations do not apply if the product is purchased within commercial, entrepreneurial, or professional circumstances. In these cases 

the product guarantee will be limited to a period of 12 months from the date of purchase. 

ITALIAN GUARANTEE

What must be done if there is a product malfunction: 

Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly.  Make sure the malfunction is 

included in those covered by the guarantee; otherwise the cost of the intervention will be borne entirely by the consumer. When requesting 

the intervention of the Assistance service at the Authorised Assistance Centre, always specify: - type of malfunction - model of the appliance 

- complete address - phone number

EUROPEAN GUARANTEE

What must be done if there is a product malfunction: 

Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly. Make sure the malfunction 

is included in those covered by the guarantee; otherwise the cost of the intervention will be borne entirely by the consumer. Request the 

intervention of the Assistance service or the address of the Authorised Technical Assistance Centre to the seller; always specify: type of 

malfunction, model of the appliance, complete address and phone number

if the malfunction arises in the first 6 months of the product's life, the consumer has the right to have the product repaired with no expense. 

From the seventh to the twenty-fourth month, if a malfunction arises, the consumer will bear the cost of the call, while the seller will pay for the 

manpower and for any spare parts used.

2.

 If the malfunction is linked to external events and/or conditions such as, including but not limited to, insufficient capacity of the systems; 

wrong installation and/or maintenance by the personnel which hasn't got the skills prescribed by the laws of the country of residence of 

the consumer; negligence; inability to use the product and wrong maintenance by the consumer, with respect to what is reported and 

recommended by the instructions manual of the product, which is part of the sales contract, this guarantee will be void. 

Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee. Similarly are excluded defects 

related to incorrect operation of the flue, according to the legislation in force in the country at the moment of purchase. Other exclusions 

include all product defects due to carelessness, accidental breakdown, tampering and/or damage during transport (scratches, dents, etc.), 

interventions carried out by unauthorised personnel and further damage caused by incorrect interventions by the consumer trying to arrange 

the initial malfunction. 

The following consumables are excluded by the guarantee: gaskets, ceramic or tempered glasses, cast iron grilles or coatings, refractory 

materials (e.g. Nordiker or others), painted, chrome-plated or golden parts, majolica ware, handles, the brazier and its related components. 

For Idro products the heat exchanger is not covered by the guarantee if a suitable condensation-proof circuit is not set up to ensure a return 

temperature of the device of at least 55°C. The guarantee excludes all the external components on which the consumer can directly operate 

during use and/or maintenance or that can be subject to wear and/or rust and stains on steel due to aggressive detergents. 

If malfunctions are signalled which are not later confirmed during check by an authorised technician, the cost of the intervention will be borne 

entirely by the consumer.

3.

 If it is not possible to restore product conformity by repairing it, the product/component will be replaced, the guarantee expiration date and 

conditions will remain the same established when the product/component to be replaced has been purchased.

4.

 Extraflame S.p.A. cannot be held liable for injury or damage which may - either directly or indirectly - be caused to persons, animals 

and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding 

installation, use and maintenance of the product, that can also be downloaded on the website.

5.

 Interventions for adjusting and/or regulating the product for the type of fuel or other reasons are excluded by the guarantee.

6.

 If the product is repaired in one of the Authorised Technical Assistance Centres indicated by Extraflame S.p.A. and if the product is replaced, 

transport will be free of charge. If the technician can repair the product at the user's place of residence and they refuse, transport to the 

workshop and redelivery will be paid by the consumer.

7.

 

After the 24 months of the guarantee have elapsed any repair intervention cost will be completely borne by the consumer.

8.

 In the case of disputes the only competent court is that of the Extraflame S.p.A. registered office - (Vicenza-Italy) 

GUARANTEE TERMS 

Содержание COMFORT PLUS CRYSTAL

Страница 1: ...MADE IN ITALY design production COMFORT PLUS CRYSTAL 004276732 Rev 001 UK pellet stoves USER MANUAL...

Страница 2: ...2 ENGLISH...

Страница 3: ...ration and logic 18 additional thermostat optional 19 user menu 19 Display 19 PELLET FEED REGULATION 19 V1 Air 20 STAND BY 20 keys locked 21 V2 Air 22 reset 22 Enable chrono 22 Chrono 22 Programming e...

Страница 4: ...WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY KNOWLEDGE PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND TH...

Страница 5: ...for ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas aretop quality artisan products and as such can have micro dots crackles and chromati...

Страница 6: ...that the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium...

Страница 7: ...ollection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical d...

Страница 8: ...sliding base Take the sliding base and position it in the pre existing flue Use chalk to mark the blocking holes of the base on the flue surface Drill 8 mm holes for the steel expansion inserts Make...

Страница 9: ...completed Fix the pedestal to the floor using strong steel plugs with a diameter of 8 mm Fix the sliding base to the frame using bolts Connect the flue gas exhaust pipe and the air vent as stated in t...

Страница 10: ...s Minimum 5 cm The insert must lie at least 1 cm above the fire surface in covering marble It is just as important to guarantee the minimum distance of 5 cm on both sides as shown in the figures above...

Страница 11: ...t works with the supplied remote control Insert extraction The extraction of the insert allows pellets to be loaded inside the feed box and to perform routine maintenance cleaning the ash pipe at the...

Страница 12: ...Standards EN plus UNI EN 14961 2 UNI EN ISO 17225 2 class a1 a2 For its products the manufacturer always recommends using pellets with a diameter of 6 mm To guarantee combustion without problems the...

Страница 13: ...e insert If the deflector is closed during the functioning phase the display will signal GRATE CLOSED CAUTION for 30 seconds together with an intermittent acoustic signal If the deflector is not opene...

Страница 14: ...eration Off pellet feed motor disabled On pellet feed motor active 1 1 1 1 Indicates the compensation function Off the function is disabled On the function is active Indicates the room temperature sta...

Страница 15: ...llets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of the fire door and the ash drawer Check that the power supply cable is connected...

Страница 16: ...te for delayed automatic shutdown 8 Menu This key allows to access the user and technical menu the technical menu is reserved for assistance 9 Increase The temperature setting can be increased by pres...

Страница 17: ...es 00 59 Date 1 31 Month 1 12 Year 00 99 Adjusting language It is possible to select the preferred language to display the various messages Controls procedure Press key 6 and set clock will appear Pre...

Страница 18: ...fitted on the appliance Once the the set temperature has been reached it will automatically go to minimum or switch off activating the Stand by function reducing pellet consumption to a minimum By def...

Страница 19: ...he previous menus up to the initial status 2 2 OFF 22 5 C 14 10 2 2 OFF 22 5 C 14 10 Installation must be performed by qualified staff and or the manufacturer s technical after sales assistance J Ther...

Страница 20: ...the stove into no pellets alarm condition when the stove displays the no pellets alarm there may be non burned pellets inside the burn pot Excess fuel the stove develops a very high flame even at low...

Страница 21: ...xceeding it by 2 C will switch off after a pre set default delay displaying STAND BY When the room temperature is 2 C lower than the setting the stove will start to work again at the set power display...

Страница 22: ...ck will appear Press key 2 several times until user is displayed Press key 6 Press key 2 until v2 air appears Use keys 4 5 to increase 4 or decrease 5 Press key 6 to confirm and key 1 to return to the...

Страница 23: ...e 1st time slot To confirm and continue programming press button 6 Press button 3 to go back to the previous parameter Stop prg1 12 00 Where ENABLE CHRONO is not present in the menu enabling is done d...

Страница 24: ...used and the frequency of use It can happen that these operations should be performed more frequently Cleaning and Maintenance by the user Routine cleaning operations as specified in this use and mai...

Страница 25: ...er 3 1 4 Use the special poker supplied to clear the holes in the burn pot 5 Place back the burn pot and push it towards the hearth wall 6 If there is an ash collector tray vacuum the ash deposits PLE...

Страница 26: ...he heat exchangers chamber must be cleaned every month as the soot deposited on the rear of the hearth wall obstructs the regular flow of fumes thereby affecting the performance and regular operation...

Страница 27: ...A B C E E E F F D F D D 27 ENGLISH...

Страница 28: ...be carried out by a qualified technician CONNECTION TO THE FLUE Vacuum and clean the pipe that leads to the flue yearly or whenever necessary If there are horizontal sections any residue must be remo...

Страница 29: ...Stove off due to temperature reached and in stand by for re ignition STAND BY EXT Stove off due to an external thermostat in stand by for re ignition Cooling stand by A new ignition is attempted when...

Страница 30: ...uthorised technician Depr alarm The mechanical depression sensor has tripped Contact after sales centre No Ignition The pellet feed box is empty Pellet feed calibration inadequate Incorrect installati...

Страница 31: ...bility to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guar...

Страница 32: ...tlet pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the prod...

Страница 33: ...33 ENGLISH...

Страница 34: ...34 ENGLISH...

Страница 35: ...35 ENGLISH...

Страница 36: ...xtraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the...

Отзывы: