ENGLISH
delta t
This function allows the hysteresis limit to be set for stove switch-on and switch-off
DeLTa T
,
used as
an interval of regulation in the event the room temperature is not managed by an external thermostat.
The exact switch-on temperature is
SeT ThermoSTaT - DeLTa T
.
The switch-off temperature is
SeT
Ther DeLTa-T
.
possible
DeLTa-T
values range from:
0.5 - 5°c
To set:
oK > SeTTINgS > DeLTa-T
reset
Allows the user to restore all editable values to the default values.
To set:
oK > SeTTINgS > reSeT.
InstallatIOn mUst Be perFOrmed By qUalIFIed staFF and/Or the manUFactUrer's aFter-sales
technIcIans.
addItIOnal FUnctIOns
FIrst lOad
This function enables the pellet loading gear motor for continuous functioning.
Before enabling this function, make sure the stove is cold and in “oFF” mode. press buttons 6 + 4 at
the same time for a few seconds until "FIrST loAd” appears on the screen.
To interrupt continuous loading, simply hold key 6 down for 2 seconds.
cOmFOrt FUnctIOn
In specific models, this function reduces the ventilation speed, thus minimising the noise levels of
the stove.
To enable, hold keys 6 + 3 pressed for 2 seconds until coMForT on is displayed on the
screen.
To disable, hold keys 6 + 3 pressed for 2 seconds until coMForT oFF is displayed on the
screen.
comfort enabled comfort disabled
InstallatIOn OF sUpplementary thermOstat (OptIOnal)
The appliance is able to control the room temperature through a supplementary thermostat (optional).
After the stove is switched on (by pressing 1 or in chrono mode), it will work to reach the set thermostat temperature, displaying WorK
(open contact) on the screen. The room sensor supplied standard will automatically be ignored.
When the thermostat reaches the temperature (closed contact) the stove will work at the minimum power level, displaying ModulATIon
on The Screen.
conTrolS procedure
A mechanical or digital thermostat is needed with a “normally open” input type.
remove the plug from the socket.
using the image to the side as a guide, connect the two thermostat wires (clean contact - no
220 V!) to the respective terminals at the back of the machine, one red and the other black.
connect the power to the stove again.
press key 3 until
SET THERMOSTAT
is set to
LOW-TA
.
25