23
ENGLISH
EASY SETuP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the easY seTUP function, it is possible to change the calibration of the volumetric weight by increasing or decreasing
the preset values.
in the stove program, the available values range from “– 3” to “+ 3”; all stoves are calibrated during production with the optimal value, which
is 0.
if there is an excessive deposit on the burn pot, access the easY seTUP program and lower the value to “- 1”; then wait until the next day and
if there is no improvement, lower it again down to a limit value of “- 3”.
instead, if it is necessary to increase the calibration of the volumetric weight of the pellet, change the factory value from “0” to “+ 1, + 2, + 3”
as required.
EXCESSIVE PELLET DEPOSIT IN BuRN POT
NORMAL OPERATION
MINIMuM PELLET DEPOSIT IN BuRN POT
-3
-2
-1
0
+1
+2
+3
THirD
DeCrease
raNge iF THe
FirsT TwO are
iNsUFFiCieNT
seCOND
DeCrease
raNge iF
THe FirsT is
iNsUFFiCieNT
FirsT DeCrease
raNge (TesT
FOr 1 DaY)
OPTimaL FaCTOrY
VaLUe
FirsT iNCrease
raNge
seCOND
iNCrease
raNge iF
THe FirsT is
iNsUFFiCieNT
THirD iNCrease
raNge iF THe
FirsT TwO are
iNsUFFiCieNT
CONTrOLs PrOCeDUre
Press key 6.
Press key 3 until
EASY SETuP
appears and confirm by pressing key 6.
Use keys 4 -5 to set the range.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
n.B.: If these adjustments do not solve the proBlem of pellet deposIts In the Burn pot, please ContaCt
your loCal servICe Centre.
front aIr
This menu allows you to set the front air motor speed. range: (
COMFORT
,
AuTO
).
when
COMFORT
mode is selected, the front air speed is reduced with respect to
AuTO
mode.
The front air is normally excluded when the product is set to minimum power, once the appropriate temperature conditions have been
guaranteed.
CONTrOLs PrOCeDUre
Press key 6.
Confirm
FRONT AIR
by pressing key 6.
Use keys 4-5 to set the desired mode.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
aIr duCtInG
This menu allows you to set the ducting motor speed. range: (
OFF
,
COMFORT
,
AuTO
).
if
COMFORT
mode is selected, the front air speed is reduced. if
OFF
mode is selected, the ventilation will turn off if the temperature of the
fumes is within certain limits.
CONTrOLs PrOCeDUre
Press key 6.
Press 3 until
AIR DuCTINg
appears and confirm by pressing 6.
Use keys 4-5 to set the desired mode.
Press key 6 to confirm and key 1 to scroll back through the menus until the initial page.
Содержание 001284000
Страница 2: ...2 ENGLISH...
Страница 5: ...TEOREMA 5 ENGLISH...
Страница 37: ...37 ENGLISH...
Страница 38: ...38 ENGLISH...