background image

2                                          

 SDL310-EU-EN V1.4   07/13

 

Introduction 

Congratulations on your purchase of the Extech SDL310 Thermo-Anemometer Datalogger. This meter 
displays and stores air velocity and temperature readings. Temperature readings from the 
thermometer built into the vane probe or from an externally connected type K or J thermocouple 
temperature probe can be displayed and recorded. Data is stored on an SD card for transfer to a PC. 
In addition, an RS232 port allows data streaming to a PC. This instrument is shipped fully tested and 
calibrated and, with proper use, will provide years of reliable service. Please visit the Extech 
Instruments website (

www.extech.com

) to check for the latest version of this User Guide. Extech 

Instruments is an ISO-9001 certified company. 
 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the 
manual for further information. 
 

 

Meter Description 

1. Thermocouple 

input 

2. 

Vane input plug 

3. 

Air velocity reading 

4. 

Units of measure 

5. HOLD 

Backlight   key 

6. MAX-MIN 

key 

7. 

SET and Clock 

  key 

8. 

PC interface jack 

9. Reset 

key 

10.  Power Adaptor jack 
11.  SD card slot 
12.  ENTER and LOG key 
13. Down 

arrow and FUNCTION key 

14. Up 

 arrow and UNITS key 

15. Power 

ON-OFF  key 

16.  Temperature reading with units of measure 
17. Anemometer 

vane 

18.  Colored dot faces the air flow 
19. Vane 

handle 

20.  Vane connecting cable 

 

Notes:

 

Battery compartment, tilt stand, and tripod mount are located on the rear of the instrument. 

Items 8, 9, and 10 are located behind the snap-off compartment cover on right side of meter. 

   www.ponpe.com

contact:

[email protected]

Содержание SDL310

Страница 1: ...USER GUIDE Vane Thermo Anemometer Datalogger Model SDL310 www ponpe com contact sale ponpe com ...

Страница 2: ...de Extech Instruments is an ISO 9001 certified company Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 Thermocouple input 2 Vane input plug 3 Air velocity reading 4 Units of measure 5 HOLD Backlight key 6 MAX MIN key 7 SET and Clock key 8 PC interface jack 9 Reset key 10 P...

Страница 3: ... minute Km h kilometers per hour knots and mph miles per hour 1 Press and hold the UNIT key for at least 1 5 seconds to switch from one unit of measure to another 2 Note that pressing and holding the UNIT key continuously allows for quicker scrolling Release the key when the desired unit of measure is displayed Thermcouple Type J or K Temperature Mode 1 Select the Thermocouple Temperature mode usi...

Страница 4: ...light ON or OFF press and hold the backlight key for at least 1 5 seconds The meter will beep when switching the backlight ON or OFF unless the beeper is disabled as described in the Setup Mode section of this user guide System Reset If the meter s keys become inoperable or if the display freezes the Reset button can be used to reset the instrument 1 Use a paper clip or similar item to momentarily...

Страница 5: ...ess and hold the LOG key for at least 1 5 seconds Automatic Datalogging In automatic datalogging mode the meter takes and stores a reading at a user specified sampling rate onto SD card The meter defaults to a sampling rate of one second To change the sampling rate refer to the Setup Mode section the sampling rate cannot be 0 for automatic datalogging 1 To begin an automatic Datalog session press ...

Страница 6: ...lable at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see examples of spreadsheet displays below Spreadsheet data example Spreadsheet example Plotting the data RS 232 USB PC Interface For streaming of data to a PC via the RS232 Output jack the optional 407001 USB kit RS232 to USB ...

Страница 7: ...ard Format t CF Select the Temperature unit of measure to C or F tYPE Select the thermocouple type to K or J Setting the Clock Time 1 Access the dAtE parameter 2 Use the arrow keys to change a value 3 Use the ENTER button to step through the selections 4 Press and hold the SET button for at least 1 5 seconds to exit to the normal operation mode or simply wait 7 seconds for the meter to automatical...

Страница 8: ...operating mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow keys to select YES to format the card select NO to abort Note that all data on the card will be lost if formatting is attempted 3 Press ENTER to confirm selection 4 Press ENTER again to re confirm 5 The meter will automatically return to the normal operating mode when formatting is complete If not press and hold the SET ...

Страница 9: ...lost 3 Replace the six 6 1 5V AA batteries observing polarity 4 Replace the battery compartment cover with the two 2 Phillips screws All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries accumulators are sold Disposal in household trash or refuse is prohibited Disposal Follow the valid legal stipulations in respect...

Страница 10: ...tion Automatic temperature compensation for the Anemometer function and the type K J thermometer function Data Hold Freeze the display reading Memory Recall Record and Recall the Maximum and Minimum readings Display update rate Approx 1 second Data Output RS 232 USB PC computer interface Operating Temperature 0 to 50 C 32 to 122 F Operating Humidity 85 R H max Auto Power OFF After 10 minutes of in...

Страница 11: ... Type K J Thermocouple Thermometer Temperature Sensor Type Resolution Range Accuracy 0 1 C 50 0 to 1300 0 C 100 0 to 50 1C 0 4 rdg 0 5 C 0 4 rdg 1 C Type K 0 1 F 58 0 to 2372 0 F 148 0 to 58 1 F 0 4 rdg 1 F 0 4 rdg 1 8 F 0 1 C 50 0 to 1200 0 C 100 0 to 50 1 C 0 4 rdg 0 5 C 0 4 rdg 1 C Type J 0 1 F 58 0 to 2192 0 F 148 0 to 58 1 F 0 4 rdg 1 F 0 4 rdg 1 8 F Note Above specifications tested under an ...

Отзывы: