3.2.2 Setting Dip Switches
ON
1
2 3 4 5
6 7
8
FIGURE 12: EXAMPLE: DIP SWITCH #1 SHOWN IN ‘ON’ POSITION
Note: Be careful when changing dip switch settings. Carefully use a pointer on the dip
switch you are going to change. DO NOT use a screw driver or apply excessive force.
3.2.3 Dip Switch Functions
Note: (Developer’s refer to Programming Manual for more information)
Table 2 – DIP Switch Setting
Dip Switch
Function
Switch Switch
Switch
LED Indication
1 & 2
Communication Interface
SW1
SW2
RS 232
Off
Off
Flashing Green
IrDA
On
Off
Flashing
Green
Bluetooth
Off
On
Flashing
Blue
802.11b
On
On
Flashing
Orange
3, 4 & 5
Baud Rate
SW3
SW4
SW5
115200
Off
Off
Off
57600
On
Off
Off
38400
Off
On
Off
19200
On
On
Off
14400
Off
Off
On
9600
On
Off
On
2400
Off
On
On
1200
On
On
On
6
Parity Bit
SW6
Parity
Enabled
On
Parity
Disabled
Off
7
Odd/Even
SW7
Odd Parity
On
Even
Parity
Off
8
Auto Power Save
SW8
Power save disabled
On
Power save enabled
Off
ANDES3 User’s Guide
Rev 1.0
16