background image

12

QUARTZ

CLASSIC

Starting the machine

Note:

Keypad functions and explanations are found on page 13.

A

B

INSTALLATION AND START-UP

i

i

Note:

 When the machine is switched on, it may automatically go into STANDBY

 

mode. To determine if the 

machine is in STANDBY mode, confirm if all of the drink buttons are flashing simultaneously.  If this is 
the case, the machine must be changed to ON

 

mode.

To exit STANDBY mode and switch to ON mode, simply press the K3 and K5 buttons simultaneously  
for one second.

  Fill the water tank to the max level (A).
   If the machine is connected to the domestic water supply, water filling will begin automatically. 
  Connect the machine’s plug to the electrical outlet (this should be done by a qualified person).
   Turn on the main power switch (B).

Содержание Quartz Classic One Touch

Страница 1: ...R TM_EN Part No 1764264_05 QUARTZ CLASSIC TECHNICAL MANUAL...

Страница 2: ...olume 13 STANDBY mode 13 SERVICE PROGRAMMING 14 Adjusting the boiler operating temperature 14 STORAGE AND DISPOSAL 15 Storing the machine 15 Disposal of machine 15 TROUBLESHOOTING 16 ALARMS AND INDICA...

Страница 3: ...3 QUARTZ CLASSIC CONTENT Capsule group Caffitaly 40 Capsule group Lavazza 42 Tank inlet 44 Vibration pump 45 Water tank 46 Water tap 48 Steam wand 50...

Страница 4: ...material damage Important Alerts against unsafe practices Observe to ensure drink quality machine performance food safety to prevent minor personal injury or damage to the machine WARNING Indicates a...

Страница 5: ...rom 65 to 110mm Used capsule drawer capacity 15 capsules Energy save mode Yes Dimension height width depth 400 260 410mm Internal water tank 1 8 L with water filter option Minimum inlet water pressure...

Страница 6: ...f Capsule group lever Tank lid Water tank Touch pad Steam tap Steam pipe Main switch Drip tray level float Drip tray Drip grid Coffee outlet Hot water outlet Hot water tap Water filter optional Height...

Страница 7: ...7 QUARTZ CLASSIC DIMENSION SKETCH QUARTZ D E A E F B C Model A B C D Min Max E F G ONE TOUCH 400 mm 260 mm 410 mm 65 mm 110 mm 92 mm 510 mm 590 mm...

Страница 8: ...mmediately Damage caused during transport should be reported to the shipping agent and the machine s distributor immediately Packaging materials are potentially dangerous and should be kept away from...

Страница 9: ...install the machine This machine must be connected to a earth grounded wall socket Ensure that the grounding system is sufficient and confirms with local regulations This machine must be connected to...

Страница 10: ...f water from the domestic water supply before connecting the machine to make sure there are no contaminants in the plumbing system Connect the flexible inlet hose included in the accessory box to the...

Страница 11: ...less frequently a domestic drain connection is required for this To use this feature follow the connection procedure explained below Note The drain pipe system can be used when the machine is connecte...

Страница 12: ...f the drink buttons are flashing simultaneously If this is the case the machine must be changed to ON mode To exit STANDBY mode and switch to ON mode simply press the K3 and K5 buttons simultaneously...

Страница 13: ...ress the button of the drink to be programmed K1 K2 K3 K4 Once pressed the coffee will start to brew Watch carefully as the coffee brews and when the desired volume of coffee is reached press the K6 b...

Страница 14: ...ting temperature you must add all buttons flashes together as explained below K5 represents one hundred degrees one flash 100 C K1 represents ten degrees one flash 10 C K2 represents single degrees on...

Страница 15: ...her residue Cover re pack the machine in its original carton and store it in a dry place where it will not be exposed to extreme temperatures or humidity When returning the machine to service after lo...

Страница 16: ...The machine does not automatically stop dispensing coffee at the preset volume The flowmeter is not functioning correctly Call technical support for assis tance The coffee s cream finish is not as hi...

Страница 17: ...king water Turn OFF the machine and contact technical support The boiler fill time is exceed because there is no water in the tank and boiler Fill the tank and restart the machine Switch Off and On NO...

Страница 18: ...rst row alternating with the second row at one second intervals The capsule drawer is full The maximum number of capsules has been reached 15 capsules Empty the capsule drawer and press the STOP butto...

Страница 19: ...Then remove the water tank and remove the 2 caps and screws as shown B WARNING The boiler may be very hot let it cool down and make sure there is no pressure in the boiler by opening the steam or wat...

Страница 20: ...ove Revisiones Rev Descripci n Fecha Aprobado i perezmoya Dibujado Comprobado Aprobado 1 Aprobado 2 Salvo indicaci n contraria cotas en mil metros ngulos en grados tolerancias 0 5 y 1 Nombre Fecha SIE...

Страница 21: ...ng Disconnect the water inlet hose via the speed fitting located in the bottom front side of the group Lift the capsule group out of the machine then disconnect the wires to the microswitch located on...

Страница 22: ...water and professional cleaning agent Leave it soaked for around 15 minutes After all necessary parts have been replaced and before you reassemble the group in the machine apply a light coating of gr...

Страница 23: ...s 01 Use a small screwdriver to remove the lock washers on the guide shafts Pull the shafts out on the left side to release the chamber Remove the old chamber and replace it with a new capsule chamber...

Страница 24: ...er to avoid injury CLEANING AND MAINTENANCE Important The widest part of the gasket must be facing forward when reassembling the gasket 1 Hold the capsule group lever open with one hand to keep the ca...

Страница 25: ...ESC81005 Clean Clean Clean Replace Capsule Pinch Chamber Caffitaly ESC82000 Lavazza ESC82005 Clean Clean Clean Replace Taps Steam Tap Body 15000336 Clean Replace Steam Pipe No Burn 35010086 Clean Clea...

Страница 26: ...Vibratory Pump 12 N A Neutral 13 38020001 Heating Element 14 60800101 Solid State Relay AC 15 60100043 Capacitive Level Detection 16 60100040 Water Level Probe 17 60103025 EMI Suppression Capacitor 18...

Страница 27: ...RTZ CLASSIC EXPLODEDVIEWS Electrical components Part Part No Description 60100320 Control Board Classic 1660092 PCB Quartz 60800101 Static Relay 4 32 60100043 Adaptive Level Detection 60900043 Power S...

Страница 28: ...28 QUARTZ CLASSIC Machine front EXPLODEDVIEW Drawing 01 07 06 05 10 09 02 23 24 08 12 14 13 15 16 11 03 04 22 25 21 26 19 20 18 17...

Страница 29: ...64342 Front Chassis Frame 10 1 30210201 Coffee Spout 11 1 50100010 Vibration Absorbing D5 12 1 10004150 Plug For Display 13 1 60101004 Silkprint For Face 14 1 60100325 Touchpad PCB Cover 15 1 60101003...

Страница 30: ...30 QUARTZ CLASSIC Machine Drawing EXPLODEDVIEW 06 05 14 04 03 02 10 08 11 13 12 01 09 07...

Страница 31: ...4 1 70001002 Threadless Drain Cup 05 1 70000041 Leg D 30 06 1 261657 Back Panel 07 1 50100010 Vibration Absorbing D5 08 1 261656 Side Panel Left 09 1 20010240 Miniswitch Support Tank 10 1 10004080 Tan...

Страница 32: ...32 QUARTZ CLASSIC Water schematic Drawing EXPLODEDVIEW Silicone Tube 10mm Silicone Tube 6mm PTFE Tube 4mm PTFE Tube 6mm WATER INLET 02 01 05 06 04 07 08 11 12 14 16 15 17 13 10 03 09...

Страница 33: ...ater Inlet 7 1 1206121 Non Return Valve Holder 8 1 1206122 Non Return Valve Ball 9 1 60100060 Flow meter 10 1 See Pg 45 Vibration Pump Assy 11 1 See Pg 36 Manifold System 12 1 See Pg 48 Steam Tap 13 1...

Страница 34: ...0 2 60000 3 30400 4 30 000 5 50010 6 30 000 7 50010 8 60100 9 25000 10 25679 11 60100 12 30000 13 65 000 14 30600 15 30 000 16 30 100 17 15100 18 38012 19 30 200 20 25 093 21 25 012 22 30 700 23 30600...

Страница 35: ...09 1 25000003 INOX GROUND WASHER 10 1 25679812 SERRATE WASHER M 12 SHAPE A 11 1 60100076 BOILER TEMPERATURA PROBE 12 1 30000003 MALE FEMALE REDUCER 3 8X1 4 13 1 65000200 NON SUCTION VALVE 14 1 3060001...

Страница 36: ...36 QUARTZ CLASSIC Manifold system Drawing EXPLODEDVIEW 01 10 10 11 12 13 11 03 04 05 06 07 02...

Страница 37: ...Nbr 60 Sh Fda D6x3 04 1 N A Gasket Seat Of Bypass 05 1 N A Bypass Spring 06 1 N A Setting Screw Of Bypass 07 1 N A O Ring 7 2 X 1 9 Fkm Green 08 1 N A Catridge Tube 6mm Legris 09 1 N A Shell Tube 6mm...

Страница 38: ...38 QUARTZ CLASSIC Capsule group chassis Drawing EXPLODEDVIEW 01 12 11 11 10 13 15 16 17 18 22 23 25 26 27 21 02 03 04 05 06 07 08 09 24 20 14 19...

Страница 39: ...t Panel Capsule Group 11 1 30210121 Slide Axis D6x84 12 4 30210135 Guide Cap D 8X11 Auto Eject 13 1 25012521 Stainless Steel Knob Washer 14 2 30210120 Axis D 6 80 Auto Eject Group 15 12 25091200 Allen...

Страница 40: ...40 QUARTZ CLASSIC EXPLODEDVIEW Capsule group Caffitaly Drawing 06 08 13 11 12 10 09 07 01 14 02 03 04 05 02 01 15...

Страница 41: ...T D7x2 VMQ 70 RED 05 1 75200059 INF NEEDLE AUTOEJECT GROUP 06 1 50000060 RETENTION GASKET AUTO EJECT GROUP CFT 07 1 30210134 RETENTION RING AUTO EJECT 08 1 75200057 NEEDLE SUPPORT CAPSULE CFT AUTOEJEC...

Страница 42: ...42 QUARTZ CLASSIC EXPLODEDVIEW Capsule group Lavazza Drawing 01 14 07 13 12 11 03 04 10 09 08 05 06 02 01 02 15...

Страница 43: ...000112 GASKET D7x2 VMQ 70 RED 05 1 25096510 SCREW PHILIPS 4 8 DIN 965 06 1 75000015 SHOWER POD D 34 07 1 50000063 RETENTION GASKET AUTO EJECT GROUP LVZ 08 1 30210134 RETENTION RING AUTO EJECT 09 1 650...

Страница 44: ...t POS PCS Part No Description 01 1 N A Tank Distributor Cover 02 1 N A Silicone O Ring 17X3mm 03 1 N A Tank Distributor Button 04 1 N A Filter 05 1 N A Tank DistributorValve 06 1 65000220 Tank Distrib...

Страница 45: ...parts list POS PCS Part No Description 01 1 60000040 Pump 220V 50Hz 02 1 1264340 Connector T forVibration Pump 03 1 1860061 Connector L male G1 8 Tube 4 Rotate 04 2 30400060 L Support Bracket 05 1 126...

Страница 46: ...46 QUARTZ CLASSIC Water tank Drawing 01 02 03 04 05 EXPLODEDVIEW 06...

Страница 47: ...rts list POS PCS Part No Description 01 1 N A Tank Handle 02 1 N A Transparent Tank 03 1 N A Spring TankValve 04 1 N A Silicone O Ring D6 02 2 62 Sh60a 05 1 N A TankValve Axis 06 1 2760065 Tank Assemb...

Страница 48: ...48 QUARTZ CLASSIC 01 02 07 06 02 05 04 03 08 Water tap Drawing 09 10 EXPLODEDVIEW 13 12 11...

Страница 49: ...Tap Steam Water Gasket Teflon 04 1 N A Spring Steam Water Tap 05 1 N A Tap Steam Water Gasket Brass 06 1 N A O Ring 12 1X2 7mm 07 1 N A Nut 3 8 08 1 N A O Ring 8 X 1 9 09 1 C40000071 Steam Water Tap K...

Страница 50: ...50 QUARTZ CLASSIC Steam wand Drawing EXPLODEDVIEW 14 15 16 01 02 06 02 05 04 03 07 08 09 17 18 10 11 13 12...

Страница 51: ...1 N A O Ring 12 1X2 7mm 07 1 N A Nut 3 8 08 1 N A Internal Spring 7X146x0 5 09 1 N A Tube PTFE 4 6 10 1 N A O Ring 6X1 11 1 N A Steam Tap Nozzle 2H M8 5 With O ring 12 1 C30370195 Steam Tap Nozzle 3H...

Страница 52: ...consumable supplies such as glassware or normal maintenance such as cleaning of filters Additionally damages of an external nature such as contaminants in the water limescaling incorrect voltage or p...

Отзывы: