UK |
7
3112005_RHG_UK
Warning
To minimise the risk of fire, electric shock, personal injury
and/or damage to the product please observe the following:
• Please always read the manual and only use the product in accordance with the
manufacturer’s instructions. If in doubt, contact one of the Exodraft specialized dealers.
•
All installations must be carried out by properly qualifi ed personnel in accordance with
national legislation and regulations.
•
This product must be earthed. Get assistance from an qualifi ed electrician when in doubt.
•
The chimney fan must always remain switched on when the fireplace is in use.
•
Ensure that the chimney has been swept before mounting the fan to avoid chimney fires.
• Prior to servicing the product, disconnect the power and ensure that it cannot accidentally
be reconnected.
•
Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is
installed.
• If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please
ensure that the design meets the requirements of BS EN15287-1. If this cannot be achie-
ved, a smoke alarm must be installed in the same room as the heat appliance.
• Note! Fans serving biomass boilers must be cleaned more often due to extensive residue/
soot building. It is essential that a regular inspection and cleaning schedule is implemen-
ted, especially in the early days of usage, to experience how often regular inspections and
cleaning should be carried out.
UK
Your energy.
Optimized.
Product information
An Exodraft RHG chimney fan is designed with horizontal discharge.
The fan must be installed on top of a chimney and creates a negative pressure (suction) along the full
length of the flue.
The fan is developed specifically for open gas fireplaces with a max. gas supply of 12.0 kW (40,900 Btu/h).
For higher gas supply values, please contact Exodraft.
The fan is part of an Exodraft system and should be connected to an EFC21 Exodraft controller for
optimal effect.
Please check out this site for advice about other Exodraft products:
www.exodraft.com
Scope of supply
•
Exodraft RHG chimney fan
• Mineral wool mat for vibration-free mounting
• Packet with location brackets and nuts
• Installation manual and user instructions
Accessories and spare parts
The table below shows the accessories and spare parts available for the RHG-models.
Accessories*
Spare parts
Flanges (for steel chimneys)
Motors
RSD - Dilution bolts (for brick chimneys)
Impellers and axial vanes
Capacitors
Mineral wool mats
SVD-RS - Vibrations dampers (for flanges on steel chimneys)
PDS - Pressure differential switch
*This manual does not describe the specific use of accessories. We refer to the separate manuals for such components.
For more details contact your Exodraft dealer.