Electrical installation
The fan and motor specifications are provided on the fan’s type plate. All the single-phased fan models are
adjustable in speed.
Wires are to be connected in accordance the wiring diagram. For further details, please see guidelines for
the Exodraft control units.
Any lightning conductor connected to the fan must respect current applicable national legislation.
Exodraft motor
Grundfos motor
8
7
6
5
4
3
2
1
AUX
MAIN
t°
P
BN
BK
BU
4
5
3
1
2
1
2
3
4
NO
NC
C
N
L1
5
YEGN
POWER SUPPLY
1 x 230 V ~ 50 Hz
6 x 0,75
BK
BN
BU
3 x 0,75
YEGN
Isolation switch
In accordance with the provisions of the applicable EU Machinery Directive a combustion-gas fan must
always have an isolation switch fitted. The isolation switch must comply with national wiring standards,
and it must be ordered separately, as it is not part of the standard Exodraft scope of delivery.