![Exodraft RHG Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/exodraft/rhg/rhg_manual_2451390015.webp)
UK |
15
3112005_RHG_UK
Installation onto a steel chimney
If the fan is to be fitted on a steel chimney, the chimney fan must be installed with an approved flange.
See the installation guide below.
Step
Action
Illustration
1
The flange must be placed so that the spigot goes
into the chimney!
Measure the diameter of the hole in the flange.
2
Then cut a hole in the mineral wool mat that
matches.
Note that there must always be a minimum of
20 mm of mat surface at any point around the
circumference of the hole.
20 mm
3
Cut the corners off the mineral wool mat, so there
is room to fit the vibration dampers.
If a temperature sensor is to be installed with the
chimney fan, cut a groove in the mineral wool mat
that is big enough for the sensor.
Now place the mineral wool mat on the flange
(between the flange and the fan).
4
Fixate the flange to the chimney fan with the use
of the vibration dampers supplied with the flange.
RHG
Содержание RHG
Страница 1: ...Your energy Optimized Chimney Fan RHG UK Read and save these instructions ...
Страница 2: ......
Страница 23: ...UK 23 3112005_RHG_UK ...
Страница 24: ...24 UK Your energy Optimized ...
Страница 25: ...UK 25 3112005_RHG_UK ...