UNPACKING 

Inspect the fan for signs of shipping damage. It is the responsibility of the customer to report any  
shipping damage to the freight carrier. 

WHAT SHOULD YOU FIND? 

Fan, (4) Housing Sheets with (4) Corner Deflectors, Damper Door Ring Assembly, Cone (4 cone panels and 4 cone 
gussets), Rear Housing Guard, Front Cone Guard, and Hardware Package 

Figure 1 

67 1/4 

14 3/8 

61 

61 

73 

Dimensions 
in inches 

Содержание MNBCDD54

Страница 1: ...s coolair com MNEFDD54L MNEFDD54M MNBCDD54L MNBCDD54M UNPACKING Inspect the fan for signs of shipping damage It is the responsibility of the customer to report any shipping damage to the freight carri...

Страница 2: ...FRAMING Page 2 FRAME CONSTRUCTION RECOMMENDED MINIMUM SPACING IS 16 Figure 2 58 3 4 SQ I D Spacing POST CONSTRUCTION Figure 3 4 x 4 Post 58 3 4 SQ I D...

Страница 3: ...two 1 4 whiz lock nuts fasten the two sheets at the overlapping holes on the inside corner of the two sheets Push the bolts from the outside in and thread the nuts on the inside This process should b...

Страница 4: ...pulley and the fan hub pulley If necessary loosen the motor pulley set screw and or the motor mounting bolts and adjust as necessary Re tighten pulley set screw and motor mounting bolts IMPORTANT Mot...

Страница 5: ...by finding the bottom cone quarter panel and one of the other panels side panel Place these two panels such that the edge of the side panel overlaps the bottom panel and the holes on the overlapping e...

Страница 6: ...rocess on the opposite side for the other handle Figure 11 shows the handle placement To mount the cone assembly pick the assembly up by the handles and place the top of the smaller end over the fan p...

Страница 7: ...et The other end of each spring should be attached to the inside door hole in the damper door To check for proper damper operation open the doors fully and allow them to close If either door fails to...

Страница 8: ...side of the fan orifice it will be necessary to loosen the two 2 3 8 bolts that secure the blade assembly s hexagonal shaft to the fan x braces center the blade assembly and tighten the bolts to 25 30...

Страница 9: ...n the idler arm see Figure 19 Re tighten the 3 8 bolt Turn the blade assembly by hand to insure free rotation Do Not Over Tension The Belt This will cause premature belt and bearing failure To check t...

Страница 10: ...d cone See Figure 20 WARNING Protect Fan and Cone from Snow and Ice Buildup WARNING Fan and or cone damage caused by this type of external source WILL NOT be covered by AMERICAN COOLAIR warranties Fig...

Страница 11: ...e disc assembly or premature bearing failure may be induced The damper door assembly should be wiped clean so that the doors will pivot freely open completely and close securely The interior sides of...

Страница 12: ...USE UNLESS ELECTRICAL WIRING COMPLIES WITH ALL APPLICABLE CODES DO NOT WIRE WITHOUT PROVIDING FOR A POWER SOURCE DISCONNECT AT THE FAN ITSELF DO NOT SERVICE EXCEPT BY A QUALIFIED MAINTENANCE TECHNICIA...