of the total amount is produced between 290 and 300 nm. The most
accurate readings of vitamin D3 photosynthesis are given by the
Solarmeter 6.4 Vitamine D3 IU per Minute, because this meter uses
the above described D3 Yield Index, and therefore calculates positive
against negative UVB, takes peak performance into account, and
then shows the actual outcome on useful UV-rays that promote the
photosynthesis of Vitamine D3. Deficiency of Vitamin D3 can result
in insufficient calcium levels which in turn can lead to reproductive
failure and health problems like rickets, osteomalacia and nutritional
metabolic bone disease. Reptiles that are kept in captivity and do not
have access to natural sunlight should be exposed to a source of UVB
to avoid Vitamin D3-related diseases.
OPERATING INSTRUCTIONS
The Exo Terra
®
SunRay bulb was designed for use with the Exo Terra
®
SunRay Fixture:
PT2315 Exo Terra
®
SunRay Fixture – 35W
PT2320 Exo Terra
®
SunRay Fixture – 50W
PT2325 Exo Terra
®
SunRay Fixture – 70W
PT2326 Exo Terra
®
SunRay bulb – 35W
PT2327 Exo Terra
®
SunRay bulb – 50W
PT2328 Exo Terra
®
SunRay bulb – 70W
See pages 27-29 for lighting rating tables.
RECOMMENDATION: Use only Exo Terra
®
SunRay bulbs as per
the wattage rating indicated on the electrical data label located
on the fixture.
MAINTENANCE
UV radiation slowly decreases over time
To assure that your
animals continuously receive the right amount of UV, we recommend
to replace the Exo Terra
®
SunRay bulbs every 12 months. Subscribe
to our “Restore the Rays” program on www.exo-terra.com to receive
a reminder when your Exo Terra
®
SunRay bulb needs to be replaced.
RECYCLING
This item bears the selective sorting symbol for waste
electronic and electrical equipment (WEEE). This means
that the product must be handled pursuant to European
Directive 2002/96/EC in order to be recycled or
dismantled to minimise it’s impact on the environment.
For further information please contact your local or regional
Authorities. Electronic products not included in the selective sorting
process are potentially dangerous for the environment and human
health due to the prescence of hazardous substances.
supervised to ensure that they do not play with the appliance.
5.
To avoid injury, do not contact hot parts, allow to cool down
before handling.
6.
Do not use the bulb for other than intended use. The use of
attachments not recommended or sold by the bulb manufacturer
may cause an unsafe condition.
7.
The Exo Terra
®
SunRay Bulb emits UV and was designed strictly
for use with reptiles. It should be operated in a way that humans
are never exposed to UV. Before handling the bulb, and to avoid
exposing yourself to the light emitted by the bulb, switch off the
bulb and let it cool down. Always use the bulb in conjunction with
a dome that was specifically designed for use with Metal Halide
Bulbs (Exo Terra
®
SunRay Fixture), so you will not be exposed to
UV-radiation.
8.
Never look directly into the bulb.
9.
The safety of this bulb is guaranteed only provided that the bulb,
adaptor, and light unit are properly installed.
10.
Do not use more than one bulb on one ballast.
11.
Damaged bulbs or bulbs that do not function properly have to be
removed immediately.
12.
Provide sufficient ventilation. Never cover the bulb or ballast.
13.
Never install the bulb near flammable objects.
14.
The housing of this bulb may only be opened by authorized
personnel or by the manufacturer.
15.
Switch off the bulb before performing any maintenance of any kind
in the terrarium.
16.
Disconnect the plug of the light unit, and any other electrical
equipment, used for the terrarium, paludarium or aqua-terrarium
before placing your hands in the water; and/or performing any
maintenance of any kind.
17.
Whenever installing, removing, changing or maintaining bulbs
always ensure that the device is unplugged.
• This equipment is FOR INDOOR USE ONLY.
• Warning: Disconnect the plug of the fixture, and any other electrical
equipment, used for the terrarium, paludarium or aqua-terrarium
before performing any maintenance of any kind.
• Warning: Whenever installing, removing, changing or maintaining
Exo Terra
®
SunRay bulbs always ensure that the fixture is
unplugged.
• The Exo Terra
®
SunRay bulb should only be operated with a suitable
ballast and fixture (e.g. Exo Terra
®
SunRay fixture).
• After switching the bulb on, it needs about 5-7 minutes to achieve
full brightness. When switched of, the bulb has to cool down for
about 10 minutes before it can be started again.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Only the faithful observation of these installation, electrical and
maintenance guidelines will ensure the safe and efficient use of
this appliance.
UV INFORMATION
The most important advantage of UVB is its contribution to the
production of Vitamin D3. An important note here is that the
wavelengths within the UVB band are not equally efficient in the
production of previtamin D3. At 298 nm, the best conversion results
are obtained. The wavelengths on both sides of this maximum
become progressively less efficient in producing previtamin D3. 60%
ENGLISH
FRANÇAIS
DEUTSCH
ESP
AÑOL
IT
ALIANO
NEDERLANDS
Содержание PT2326
Страница 16: ...30 ENGLISH FRAN AIS DEUTSCH ESPA OL ITALIANO NEDERLANDS...
Страница 17: ...32 Rev 08 12 EU Printed in China...