Test Setup - Test Configurator, Timer, and System
MaxTester
149
RFC 2544 - Subtests
Thresholds Button
Note:
For
Dual Test Set
, thresholds are configurable for
Local to Remote
and
Remote to Local
directions at the exception of Round-Trip Latency
Threshold for which the value is unique. For
Dual Port
topology, thresholds
are configurable for both port directions.
Throughput Threshold
sets the threshold
1
value used to declare a
pass/fail verdict for all frame sizes when applicable. The range is as
follows:
Back-to-Back Threshold
sets the threshold
value in percentage of
frames per burst to declare a pass/fail verdict for all frames sizes when
applicable.
Frame Loss Threshold (%)
sets the threshold
2
value of frame loss for
all frame sizes when applicable.
1. The verdict is PASS when the received/measured value is greater or equal to the threshold value.
Interface
Speed
Max. Rate
%
Mbit/s
Gbit/s
10 Mbit/s
0.0 to 100.0
a
a.
Defalut value.
0.0 - 10.0
Not Applicable
100 Mbit/s
0.0 to 100.0
0.0 - 100.0
Not Applicable
1000 Mbit/s 0.0 to 100.0
0.0 - 1000.0
0.0 - 1.0
10G LAN
0.0 to 100.0
0.0 - 10000.0
0.0 - 10.0
10G WAN
b
b.
The maximum value for 10G WAN may be lower depending on the frame size. The
maximum value will be adjusted for each frame size.
0.0 to 92.857
0.0 - 9285.7
0.0 - 9.2857
100G
0.0 to 100.0
0.0 - 100000.0
0.0 - 100.0
2. The verdict is PASS when the received/measured value is lower or equal to the threshold value.
Содержание MAX-800 Series
Страница 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Страница 16: ......
Страница 18: ......
Страница 26: ......
Страница 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Страница 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Страница 62: ......
Страница 208: ......
Страница 414: ......
Страница 426: ......
Страница 446: ...Glossary 438 MAX 800 Series Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 476: ......
Страница 492: ...Index 484 MAX 800 Series Z Z0 344 Z1 346 Z2 349 Z3 353 Z4 353 Z5 353 Z6 355 Z7 356 Zero Code Suppression 169...
Страница 494: ...0 5 1 5 48 5 0 176 W d y K y K D...