EXFO bv10 Скачать руководство пользователя страница 21

BV10-100 and BV10-1000

15

4

Physical Interfaces, LEDs, and 

Buttons

This section describes all connectors (ports), LEDs, and buttons available 
on the BV10-100 and BV10-1000 units. 

BV10 Models 

BV10-100 

BV10-1000 

LAN

TEST

CONSOLE

LAN

TEST

CONSOLE

Laser radiation emitted from this port when LASER LED is on.

Содержание bv10

Страница 1: ...User Guide Performance Endpoint Unit BV10 ...

Страница 2: ...ingements of patents or other rights of third parties that may result from its use No license is granted by implication or otherwise under any patent rights of EXFO EXFO s Commerce And Government Entities CAGE code under the North Atlantic Treaty Organization NATO is 0L8C3 The information contained in this publication is subject to change without notice Trademarks EXFO s trademarks have been ident...

Страница 3: ...rence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the in...

Страница 4: ...odels 15 Port Availability on BV10 16 Connecting the TEST Port Interface 16 Connecting the Management Interfaces 18 LEDs 20 RESET and DEFAULT Buttons 21 5 Managing BV10 Verifier on BrixWorx 23 Configuring BV10 Verifier for BrixWorx Registry 23 Configuring a Test 24 Verifier Health Information 28 6 Introducing the BV10 CLI 29 Command Line Interface 29 Connecting to the BV10 to a Console 30 Entering...

Страница 5: ...ling and Disposal Applies to European Union Only 84 11 Troubleshooting 85 Solving Common Problems 85 Contacting the Technical Support Group 86 Transportation 86 12 Warranty 87 General Information 87 Liability 88 Exclusions 89 Certification 89 Service and Repairs 90 EXFO Service Centers Worldwide 91 A Specifications 93 General Specifications 93 Electrical Interface 95 Optical Interface 95 B Glossar...

Страница 6: ......

Страница 7: ...or service turn up troubleshooting and performance monitoring Offers complete network visibility at a third of the cost of traditional Ethernet NID solutions Simple and remote management for zero truck roll network maintenance Completely standards based supporting Ethernet OAM with 802 1ag and Y 1731 message response as a performance endpoint as well as TWAMP RFC 5357 Capability to perform full li...

Страница 8: ...V10 Verifier is designed specifically for Ethernet OAM Handling UDP Echo Responder TWAMP Light Responder and Smart Loopback test features These features are enabled by loading the tests on the Verifier Information page Additional Services section and in some cases specifying parameters such as a UDP Listening port for TWAMP or the mode for Smart Loopback For more information refer to the BrixWorx ...

Страница 9: ...oceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Do not proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in component damage Do not proceed unless you understand and meet the req...

Страница 10: ......

Страница 11: ...ed herein may result in hazardous radiation exposure or impair the protection provided by this unit IMPORTANT When you see the following symbol on your unit make sure that you refer to the instructions provided in your user documentation Ensure that you understand and meet the required conditions before using your product IMPORTANT Other safety instructions relevant for your product are located th...

Страница 12: ...his product employs Class 1 Laser SFP Invisible laser radiation may be encountered at the output port The laser classification is reproduced on the pluggable transceiver or in its documentation WARNING When the LASER LED is on or flashing the BV10 is transmitting an optical signal on the SFP transceiver port ...

Страница 13: ...is installed and used CAUTION Electrostatic Discharge ESD Sensitive Equipment Units can be damaged by static electrical discharge To minimize the risk of damage dissipate static electricity by touching a grounded unpainted metal object before removing inserting or handling the unit before connecting or disconnecting cables to from the unit before inserting or removing SFP transceiver to from the u...

Страница 14: ...n Your Unit One or more of the following symbols may also appear on your unit Symbol Meaning Direct current Alternating current Plus positive polarity Minus negative polarity The unit is equipped with an earth ground terminal The unit is equipped with a protective conductor terminal ...

Страница 15: ... a rack 1 Attach the brackets of the supplied shelf unit to your rack using the supplied screws 2 If cables have been attached to the BV10 disconnect all of them as well as the ground lug from the unit 3 Slide the unit into the desired slot from front to back 4 With the unit completely inserted into the slot tighten the thumb screw at the back of the unit 5 Connect all cables and the ground lug as...

Страница 16: ... As soon as the BV10 is connected to a live power supply the POWER LED turns on If the POWER LED does not turn on there is a power failure at the source or the unit is damaged The STATUS LED indicates whether or not the unit is ready for use If the STATUS LED is off the unit is booting up If it is green or red the unit has booted refer to STATUS on page 20 ...

Страница 17: ...nd the BV10 1 Loosen the locking nut on the grounding lug 2 Using a 12 AWG wire twist the wire around the lug so that it is touching the flat surface of the washer The wire must be twisted between the washer and the locking nut 3 Tighten the locking nut 4 Connect the other end of the wire to the ground distribution network WARNING The BV10 DC version is intended to be grounded Ensure that the unit...

Страница 18: ...her 24 V DC or 48 V DC connector To connect the BV10 to a DC power source 1 Using 14 16 AWG copper insulated wires and the supplied connector insert the two stripped wires into the connector and tighten the screws firmly Either use non stranded wire or crimp a ferrule onto the wire Be sure to respect the polarity The positive supply wire lead must be on the right side of the connector and the nega...

Страница 19: ... Connect the plug to one of the two DC input connectors on the BV10 unit and tighten the screws firmly 48 V DC Unit Supplied connector Negative supply wire lead on the left Positive supply wire lead on the right 24 V DC Unit Supplied connector Negative supply wire lead on the left Positive supply wire lead on the right ...

Страница 20: ...e building installation Permanently connected equipment must have a switch or circuit breaker for disconnection If the switch is not part of the kit Include a switch or circuit breaker in the installation The switch must be located easily and placed near the equipment The switch must be specified as the disconnecting device for the equipment WARNING To avoid serious injuries as well as irreparable...

Страница 21: ... LEDs and Buttons This section describes all connectors ports LEDs and buttons available on the BV10 100 and BV10 1000 units BV10 Models BV10 100 BV10 1000 LAN TEST CONSOLE LAN TEST CONSOLE Laser radiation emitted from this port when LASER LED is on ...

Страница 22: ...ed to the RJ45 test port The electrical ports is RJ45 for category 5 unshielded twisted pair UTP Refer to Ethernet Cables on page 102 for cable specifications Supported electrical rates are For BV10 100 10 Mbit s and 100 Mbit s For BV10 1000 10 Mbit s 100 Mbit s and 1000 Mbit s Port Label Description Model BV10 100 BV10 1000 TEST PORT 10 100 Mbit s electrical RJ45 Test port 10Base T and 100Base TX...

Страница 23: ...e with LC connector Insert an SFP module into the SFP test port slot on the BV10 Refer to Optical Interface on page 95 for more information on supported SFP Carefully connect optical fibre cables to the SFP s IN and OUT ports To ensure good signal quality make sure that the optical fibre connector is fully inserted into the optical connector port CAUTION To prevent exceeding the maximum input powe...

Страница 24: ... using the LAN Port LAN Port Connecting a typical management network to the 10 100 Mbit s Ethernet LAN port provides remote access to the BV10 Command Line Interface CLI using either Telnet or SSH session To connect remotely to the BV10 using the LAN port connect both the BV10 LAN port and the remote PC to the same Management network using a standard straight through Ethernet cable with RJ45 conne...

Страница 25: ...RS 232 DE 9F DCE pinouts as viewed from the front of the BV10 The following table indicates the DB9 pinouts To connect locally connect a PC to the CONSOLE port using an RS 232 straight cable with a DB9 connector Pin Number Description 1 4 and 6 Connected together inside the BV10 7 and 8 Connected together inside the BV10 5 Signal ground 2 TX output of the BV10 3 RX input of the BV10 9 Not internal...

Страница 26: ...up On Red indicates that the link on the test port is down Off indicates that the unit is not yet booted SPEED Off indicates 10 Mbit s On Green indicates 100 Mbit s On Amber indicates 1000 Mbit s BV10 1000 only LINK ACT Electrical and Optical Ports On Green indicates that the link is up there is no activity Off indicates that the link is down there is no activity Blinking Green indicates that the ...

Страница 27: ...oot the BV10 Press the RESET button once to reboot the BV10 While rebooting the BV10 displays a series of messages if the unit is connected to a console The reboot command can also be used to reboot the BV10 refer to reboot on page 45 DEFAULT Button The DEFAULT button is used to reset the BV10 to the factory default settings Press the DEFAULT button once to reset the BV10 to its factory default se...

Страница 28: ......

Страница 29: ...de the changes done using the CLI prompt Configuring BV10 Verifier for BrixWorx Registry The BV10 Verifier must be configured before you can use it in the BrixWorx system Once the configuration of a BV10 Verifier is complete you must add it to BrixWorx just like any other Verifier Configure the BV10 Verifier To configure the BV10 Verifier for use in the BrixWorx system 1 Access the CLI prompt usin...

Страница 30: ... have configured a BV10 you must add it to BrixWorx Refer to the BrixWorx User Guide for more information on how to add the BV10 Verifier to the BrixWorx system Configuring a Test Only a specific set of BrixWorx tests are supported by the BV10 Verifier All tests supported on the BV10 Verifier are available through BrixWorx Ethernet OAM Handling UDP Echo Responder TWAMP Light Responder Smart Loopba...

Страница 31: ...Managing BV10 Verifier on BrixWorx BV10 100 and BV10 1000 25 Configuring a Test To configure a test on a BV10 Verifier using the BrixWorx Operations Centre 1 Login to BrixWorx 2 Select Verifiers ...

Страница 32: ... on BrixWorx 26 BV10 Configuring a Test 3 Click the name of the Verifier on which you want to configure the test 4 Click the edit button for Additional Services You can choose to load a specific test or service on this page ...

Страница 33: ...ests that you want to configure on the BV10 Verifier For the TWAMP Light Responder test you must enter the UDP port value to load the test For Smart Loopback test select Ethernet Ethernet all unicast IP or UDP TCP to load the specific test Refer to Test Applications on page 73 for more information about the tests that you can load on the BV10 Verifier 7 To run the SSH or Telnet service select Run ...

Страница 34: ...ports results to BrixWorx based on its polling interval The following figure shows an example of Verifier health information To display the Verifier Health page select the Verifier Health category on the Verifier Information page See Configure the BV10 Verifier on page 23 for more information on how to set the interval for Verifier status reporting and refer to the Verifiers chapter in the BrixWor...

Страница 35: ... and syntax Command Line Interface The Command Line Interface CLI allows to configure and manage the operation of the BV10 by sending commands to the BV10 using either the CONSOLE Port a Telnet session LAN or TEST Port or Secure Shell SSH session LAN or TEST Port Note Telnet and SSH provide the same functionality except SSH provides a secure channel Refer to console telnet ssh server enable disabl...

Страница 36: ...he BV10 CONSOLE Port The CONSOLE port is always available for CLI use To use the CONSOLE port 1 Ensure that your PC is connected to the BV10 s CONSOLE port Refer to CONSOLE Port on page 19 2 Use a terminal application to connect with the BV10 through its CONSOLE port 2a Start the terminal application 2b Set the connection configuration to 9600bps 8 data bits no parity 1 stop bit 9600 8 N 1 2c Esta...

Страница 37: ...PC run a terminal application 3 Select Telnet or SSH connection type The use of Telnet server is enabled by default on the BV10 The use of SSH server is disabled by default on the BV10 and must be enabled as well as the password must be defined refer respectively to console telnet ssh server enable disable on page 61 and password set password on page 61 the user name is exfo The CLI supports SSHv2...

Страница 38: ...console in band enable disable command controls in band management on the test port By default in band management on the test port is enabled Refer to console in band enable disable on page 62 for more information To use the TEST port 1 Ensure that both your PC network interface and the BV10 s TEST port are connected to the same Management network Refer to Connecting the TEST Port Interface on pag...

Страница 39: ...special characters such as the slash and colon are supported Commands and parameters are not case sensitive You can specify no parameter one parameter or multiple parameters separated with comma Abbreviating Commands The CLI allows you to type only as much of a command that it is required to make it unambiguous For example sh ve is the equivalent of typing show version because show is the only key...

Страница 40: ...does not allow the CLI to distinguish console from clear If it cannot be unambiguously determined the CLI displays a list of possible commands and parameters that begin with the partial keyword When the rest of the command can be completed it appears in its completed form on the same line when you press the Tab key If the command cannot be completed the possible values appear on the following line...

Страница 41: ...mmand history buffer each time you press the up arrow key down arrow Scrolls forward through all of the commands that have been recalled using the up arrow Tab Completes the command or keyword See Completing Commands on page 34 for more information Ctrl D Deletes the character at the cursor s position Ctrl H Deletes the character to the left of the cursor s position Ctrl I Re displays the current ...

Страница 42: ...ll most recent commands from the history buffer using either Up arrow key Ctrl P Down arrow key and Ctrl N see above table for more information Ctrl U Deletes all characters on the line Ctrl W Deletes the previous word Ctrl Y Pastes from the clipboard Esc B Moves the cursor to the start of the previous word Esc C Capitalizes the current character Esc D Deletes all characters in a word from the cur...

Страница 43: ...le timeout that logs users out of a CLI session and closes the connection if there has been no activity for a specified period of time An idle timeout can be set for each type of access CONSOLE port Telnet session or SSH session It can also be disabled Refer to console telnet ssh serial idle timeout value_in_seconds on page 62 for more information on how to configure the timeout period In addition...

Страница 44: ......

Страница 45: ...mpt Note Refer to Introducing the BV10 CLI on page 29 for more information on CLI and its features Conventions The following table lists the conventions used in this chapter to represent command syntax Command Availability All CLI commands can be sent through the LAN and CONSOLE ports Only a subset of commands can be sent through the Test port Convention Description Example Pipe symbol Choice betw...

Страница 46: ...terface lan duplex half full 66 interface lan flow auto 66 interface lan flow rx none 66 interface lan speed 10 100 force 65 interface lan test address netmask IP_address netmask dhcp 68 interface lan test cable auto 67 interface lan test gateway IP_address none 68 interface lan test gateway dhcp none 69 interface lan test speed auto 64 interface lan test vlan value none 67 interface test cable st...

Страница 47: ...ry port 55 server discovery universal 54 server discovery write 55 show config 59 show interface 51 show server discovery local 56 show server discovery network 56 show server discovery port 56 show server discovery universal 56 show server log 57 show statistics 49 show sysinfo 46 show version 46 smart loopback enable disable 70 smart loopback mode ethernet all unicast ethernet ip udp tcp 70 twam...

Страница 48: ...stem reboot logout or exit show sysinfo 45 45 46 Software Management show version load image 46 47 Statistics show statistics clear statistics 49 50 Interface Information show interface 51 Tools ping 53 Server Discovery server discovery local server discovery network server discovery universal server discovery port server discovery write show server discovery local show server discovery network sh...

Страница 49: ...s a list of possible parameters associated with the keyword Syntax help Example bv10 100 help List of commands clear Clears Statistics console Configure Telnet SSH Serial In Band management settings eth oam Enables disables Ethernet OAM exit logout Logout of the CLI help Shows help information interface1 Configures network interface load Upgrades system image password Changes password ping Ping IP...

Страница 50: ...the end of a complete or partial keyword command or parameter displays the complete keyword on the next line if the keyword is unambiguous If the partial keyword is ambiguous displays the possible choices on the next line after a complete or partial keyword and a space displays a list of parameters If the partial keyword is ambiguous displays the possible choices The question mark character is not...

Страница 51: ...it the CLI prompts for confirmation The RESET button can also be used to reboot the BV10 Refer to RESET Button on page 21 for more information Syntax reboot Example bv10 100 reboot Reboot system y n logout or exit Description Logs out of the CLI session The logout and exit commands are exactly the same Syntax logout exit Example bv10 100 logout ...

Страница 52: ...eed B Status Applied to DC version only and are monitored every 5 seconds Syntax show sysinfo Example bv10 100 show sysinfo S W VERSION Linux 2 6 25 8 Wed Apr 16 14 47 51 EDT 2014 H W BV10 1000 AC H W VERSION C H W ID 800000638428 SERIAL NUMBER 638428 MFG DATE 23 03 12 UNIT HEALTH OK show version Description Displays the current software firmware versions Syntax show version Example bv10 100 show ...

Страница 53: ...V10 must be rebooted in order for the new software image to be applicable You can use either the RESET button or the reboot command Refer to RESET Button on page 21 and reboot on page 45 for more information The LAN or the Test port can be used for loading a software image However loading a software image using the Test port stops all applications running on the BV10 the following message is displ...

Страница 54: ...d 192 168 1 1 image_name img Example bv10 100 load image lan tftp 10 17 1 75 BV 10_4 0SP1 img WARNING Performing image upgrade Please DO NOT power down Use CTRL C to abort Shutting down processes for upgrade done Transferring BV 10_4 0SP1 img from 10 17 1 75 using tftp done 5149757 bytes Unpacking image file done Writing to device 1 done Writing to device 2 done Updating configs done Updating boot...

Страница 55: ...t packets UDP Echo Control enabled or disabled Number of processed UDP Echo packets Ethernet OAM Global Control enabled or disabled Number of processed Ethernet OAM Loopback messages Number of processed Ethernet OAM Delay Measurement messages Number of processed Ethernet OAM Link Trace messages Syntax show statistics Example bv10 100 show statistics Smart Loopback Control enabled Smart Loopback St...

Страница 56: ...CLI Command Reference 50 BV10 Operation Commands clear statistics Description Clears the counter of all statistics Syntax clear statistics Example bv10 100 clear statistics Clearing statistics ...

Страница 57: ...efault Gateway Speed Duplex Link status Auto negotiation status DHCP status VLAN MDI MDI X status Flow control Transceiver type Test port on BV10 1000 only Additional information for BV10 1000 optical port Laser Control SFP vendor manufacturing information as per SFF 8472 ID Part Number Serial Number Vendor Name Connector Type e g LC MT RJ Speed Type for example SR IR LR Wavelength and Mode SMF or...

Страница 58: ... E5 60 GATEWAY 10 17 1 2 SPEED 100Mb s DUPLEX Full LINK yes AUTO NEG on DHCP Disabled VLAN Disabled MDI 0 FLOW CONTROL TEST PORT IP_ADDRESS 10 16 7 138 NETMASK 255 255 0 0 MAC_ADDRESS 00 03 01 FF 6B 70 GATEWAY 10 16 1 1 SPEED 1000Mb s DUPLEX Full LINK yes AUTO NEG on DHCP Disabled VLAN Disabled MDI Normal FLOW CONTROL None TRANSCEIVER Electrical show interface ...

Страница 59: ...parameters can be entered in any order If a parameter is not specified the default value is used as follows 4 for repetition number_of_packets 32 for size size_in_bytes 128 for ttl value 1000 for delay value_in_ms 4000 for timeout value_in_ms Example bv10 100 ping 10 10 10 20 lan PING 10 10 10 20 10 10 10 20 from 10 10 10 180 eth0 24 52 bytes of data 32 bytes from 10 10 10 20 icmp_seq 1 ttl 128 ti...

Страница 60: ...very local IP address Example bv10 100 server discovery local 10 192 3 34 server discovery network Description Sets the BrixWorx network registry IP address for communication Syntax server discovery network IP address Example bv10 100 server discovery network 10 192 3 3 server discovery universal Description Sets the BrixWorx universal registry IP address for communication Syntax server discovery ...

Страница 61: ...er discovery local network port universal and saves the setting Once the configuration is changed the Verifier is rebooted Syntax server discovery write Example bv10 100 server discovery write Writing changes Password Configuration changed Rebooting verifier Password brix verifier line 31 usr bin whoami No such file or directory Stopping the Brix Verifier Agent done Verifier application stopped Pa...

Страница 62: ...for communication Syntax show server discovery network Example bv10 100 show server discovery network network host 10 192 2 3 show server discovery universal Description Displays the BrixWorx universal registry IP address for communication Syntax show server discovery universal Example bv10 100 show server discovery universal universe host 10 192 2 33 show server discovery port Description Display...

Страница 63: ...I Command Reference BV10 100 and BV10 1000 57 Operation Commands show server log Description Displays the server log for the local BrixWorx registry Syntax show server log Example bv10 100 show server log ...

Страница 64: ...Interface Configuration interface test transceiver electrical optical interface test laser on off interface lan test speed auto interface test speed 10 100 1000 auto interface test speed 10 100 1000 force interface lan speed 10 100 force interface test speed 1000 auto interface lan duplex auto interface lan duplex half full interface lan flow auto interface lan flow rx none interface lan test cabl...

Страница 65: ...cription Displays all BV10 configuration parameters as follows Console Console in band managementa Console Passworda Console Timeout Telneta Telnet Timeout SSHa and SSH Timeout Interfaces LAN port IP Address Subnet Mask Gateway Auto Speed Speed Duplex Flow MDI VLAN ID TEST port IP Address Subnet Mask Gateway Auto Speed Speed MDI Transceiver Transceiver type VLAN ID VLAN Priority Test applications ...

Страница 66: ...AN_GATEWAY 10 17 1 2 LAN_AUTO_SPEED on LAN_SPEED 10 100 LAN_DUPLEX auto LAN_FLOW 0 LAN_MDI 0 LAN_VLAN_ID none TEST_ADDRESS 10 16 7 138 TEST_MASK 255 255 0 0 TEST_GATEWAY 10 16 1 1 TEST_AUTO_SPEED on TEST_SPEED 10 100 1000 TEST_MDI 2 TEST_TRANSCEIVER off TEST_TRANSCEIVER_TYPE electrical TEST_VLAN_ID none TEST_VLAN_PRIORITY 1 Test Applications SMART_LOOPBACK_ENABLE enabled SMART_LOOPBACK UDP TCP ETH...

Страница 67: ...y setting password password clear Description Clears the BV10 password Syntax password clear Example bv10 100 password clear clearing password console telnet ssh server enable disable Description Enables or disables the Telnet and or SSH servers Before enabling SSH you must set a password for the CLI see password set password on page 61 If you attempt to enable SSH before setting a password the fo...

Страница 68: ...gures the port number that can be used to communicate with the BrixWorx server from the Test port Syntax console in band port port_valueh Example bv10 100 console in band port 300 console telnet ssh serial idle timeout value_in_seconds Description Sets the idle timeout for the Telnet server SSH server or serial console communication session Each connection method can have its own timeout By defaul...

Страница 69: ...or the TEST port Duplex and Flow Control are not configurable and respectively set to Full and None interface test transceiver electrical optical Description Sets the TEST port transceiver type to either electrical or optical This command applies to the BV10 1000 only This command cannot be sent through the Test port Syntax interface test transceiver electrical optical Example bv10 100 interface t...

Страница 70: ... speed 10 100 1000 auto Description Auto negotiates the specified electrical TEST port speed 10 100 1000 This command cannot be sent through the Test port Syntax interface test speed 10 100 1000 auto Example bv10 100 interface test speed 100 auto interface test speed 10 100 1000 force Description Forces the electrical TEST port speed 10 100 1000 to the specified value no auto negotiation is perfor...

Страница 71: ...orce Example bv10 100 interface lan speed 100 force interface test speed 1000 auto Description Auto negotiates the specified optical TEST port speed 1000 This command cannot be sent through the Test port Syntax interface test speed 1000 auto Example bv10 1000 interface test speed 1000 auto interface lan duplex auto Description Auto negotiates the LAN duplex speed This command cannot be sent throug...

Страница 72: ...ull interface lan flow auto Description Auto negotiates the flow control for the LAN port to either receive rx or none This command cannot be sent through the Test port Syntax interface lan flow auto Example bv10 100 interface lan flow auto interface lan flow rx none Description Sets the flow control for the LAN port to the receive rx or none no auto negotiation is performed This command cannot be...

Страница 73: ...iption Sets the electrical Test port cable as straight This command cannot be sent through the Test port Syntax interface test cable straight Example bv10 100 interface test cable straight interface lan test vlan value none Description Sets the VLAN ID of the LAN or TEST port to the specified value or disables VLAN none Syntax interface lan test vlan value none Example bv10 100 interface lan vlan ...

Страница 74: ...v4 addressing The netmask value can be specified in either dotted decimal notation or CIDR format For example 192 168 1 1 255 255 255 0 192 168 1 1 24 Syntax interface lan test address netmask IP_address netmask dhcp Example bv10 100 interface test address netmask 10 10 10 181 24 address mask changing static address to 10 10 10 181 255 255 255 0 interface lan test gateway IP_address none Descripti...

Страница 75: ...erface IP address of the port is set to DHCP sets the gateway to the specified IP address or none When the IP address of the port is changed from manual to DHCP the default gateway is automatically set to DHCP The gateway can still be configured to none Syntax interface lan test gateway dhcp none Example bv10 100 interface lan gateway 10 17 1 2 ...

Страница 76: ...lected Refer to Smart Loopback Test on page 74 for more information Syntax smart loopback enable disable Example bv10 100 smart loopback disable smart loopback disable smart loopback mode ethernet all unicast ethernet ip udp tcp Description Sets the Smart Loopback feature to one of the following modes Ethernet All Unicast Ethernet IP UDP TCP default Refer to Smart Loopback Test on page 74 for more...

Страница 77: ... Sets the TWAMP UDP listening port When UDP Echo is enabled it uses port 7 If you attempt to set the TWAMP UDP listening port to 7 the following error message is displayed Command is not allowed UDP Echo is enabled Syntax twamp udp port value Example bv10 100 twamp udp port 4444 twamp udp port 4444 udp echo enable disable Description Enables or disables the UDP Echo application UDP Echo is enabled...

Страница 78: ...ation Commands eth oam enable disable Description Globally enables or disables the Ethernet OAM handling application Ethernet OAM handling is enabled by default Syntax eth oam enable disable Example bv10 100 eth oam disable eth oam disabled ...

Страница 79: ...Link up event on the Test port Any Test port configuration change Test control changes from disabled to enabled applies to TWAMP Light UDP Echo and Ethernet OAM handling The Smart Loopback Operational Status changes from Not Operational to Operational applies to Smart Loopback test The Smart Loopback mode is changed applies to Smart Loopback test All test application counters can be manually reset...

Страница 80: ...ts the following Smart Loopback modes UDP TCP default Swap MAC addresses IP addresses UDP or TCP ports when present and addressed to the unit s TEST port MAC IP address In other words swap from Layer 2 up to Layer 4 when present IP Swap MAC addresses IP addresses when present and addressed to the unit s TEST port MAC IP address In other words swap from Layer 2 up to Layer 3 when present Ethernet S...

Страница 81: ... Laser Off produces a Link Down status for the optical transceiver port Smart Loopback Mode Link Down Link Up DHCP Acquired DHCP Renewing or Manual IP address DHCPAcquiring or DHCP Failed Ethernet All Unicast Not Operational Operational Operational Ethernet Not Operational Operational Operational IP Not Operational Operational Not Operational UDP TCP Not Operational Operational Not Operational ...

Страница 82: ...bled even during software upgrades on the Test port The following table lists the Ping test parameters and default values where applicable The Ping test returns the following statistics Number of packets transmitted Number of packets received Percentage of packet loss Round trip time rtt in ms minimum average maximum and standard deviation values Refer to ping on page 53 for more information Param...

Страница 83: ...VLAN ID equals the VLAN ID of the Test port if configured Destination IP address equals the IP address of the Test port Protocol equals UDP 17 UDP destination port equals the configured TWAMP Listening UDP port The TWAMP Light Responder test supports wire speed operation Unauthenticated mode is assumed The TWAMP Light Responder test can be enabled default or disabled Refer to twamp enable disable ...

Страница 84: ...is enabled default Destination MAC address equals the MAC address of the Test port VLAN ID equals the VLAN ID of the Test port if configured Destination IP address equals the IP address of the Test port Protocol is UDP 17 UDP destination port is 7 UDP Echo as per RFC862 The UDP Echo Responder test supports wire speed operation The UDP Echo Responder test can be enabled default or disabled Refer to...

Страница 85: ... is done which allows the BV10 to operate in promiscuous mode the unit operates as a MEP at multiple levels without any MEG level configuration Ethernet OAM handling can be globally enabled default or disabled Refer to eth oam enable disable on page 72 for more information The BV10 listens for and responds to the following Ethernet OAM messages Loopback The BV10 responds to Unicast OAM Loopback me...

Страница 86: ...als the MAC address of the Test port EtherType is 0x8902 OpCode is 47 DMM Link Trace The BV10 responds to Ethernet OAM Link Trace messages when all of the following criteria are met Global Ethernet OAM handling is enabled default Destination MAC address is 01 80 C2 00 00 3y where y is a value between 8 F hexidecimal EtherType is 0x8902 OpCode is 5 LTM Target MAC address equals the MAC address of t...

Страница 87: ... In the case of a power failure the BV10 unit recovers automatically when power is restored returns to the same state as before the power failure maintains all configuration parameters such as Test port Management port and Smart Loopback mode settings ...

Страница 88: ......

Страница 89: ... and dry area Keep the unit out of direct sunlight Avoid high humidity or significant temperature fluctuations Avoid unnecessary shocks and vibrations If any liquids are spilled on or into the unit turn off the power immediately disconnect from any external power source and let the unit dry completely WARNING The use of controls adjustments and procedures namely for operation and maintenance other...

Страница 90: ... dry air CDA or a air gun to blow out the dust or contamination 2 Re inspect the connector 3 If the connector is still not clean use a commercial cleaner recommended by the SFP manufacturer Note Refer to the transceiver manufacturer for more detailed cleaning recommendations and instructions Recycling and Disposal Applies to European Union Only For complete recycling disposal information as per Eu...

Страница 91: ...ting the signal There is a configuration mismatch between the inserted SFP and the rate selected for the test Ensure that the SFP is supporting the rate used for the test The SFP is not compatible with the BV10 1000 Ensure to use a compatible SFP CLI command returns Operation failed address netmask not permitted Same subnet as other interface LAN and TEST ports IP addresses are under same subnet o...

Страница 92: ...r feedback manual exfo com To accelerate the process please have information such as the name and the serial number see the product identification label as well as a description of your problem close at hand Transportation Maintain a temperature range within specifications when transporting the unit Transportation damage can occur from improper handling The following steps are recommended to minim...

Страница 93: ...ring the warranty period and found to meet all published specifications EXFO will charge standard calibration fees THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL EXFO BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IMPORTANT The wa...

Страница 94: ...ll be responsible for any failure in the performance of other items to which the product is connected or the operation of any system of which the product may be a part EXFO shall not be liable for damages resulting from improper usage or unauthorized modification of the product its accompanying accessories and software ...

Страница 95: ...cts are not covered by this warranty This warranty excludes failure resulting from improper use or installation normal wear and tear accident abuse neglect fire water lightning or other acts of nature causes external to the product or other factors beyond the control of EXFO Certification EXFO certifies that this equipment met its published specifications at the time of shipment from the factory I...

Страница 96: ...tions under which it was observed 5 Return the equipment prepaid to the address given to you by support personnel Be sure to write the RMA number on the shipping slip EXFO will refuse and return any package that does not bear an RMA number Note A test setup fee will apply to any returned unit that after test is found to meet the applicable specifications After repair the equipment will be returned...

Страница 97: ...services exfo service centers EXFO Headquarters Service Center 400 Godin Avenue Quebec Quebec G1M 2K2 CANADA 1 866 683 0155 USA and Canada Tel 1 418 683 5498 Fax 1 418 683 9224 support exfo com EXFO Europe Service Center Winchester House School Lane Chandlers Ford Hampshire S053 4DG ENGLAND Tel 44 2380 246800 Fax 44 2380 246801 support europe exfo com EXFO Telecom Equipment Shenzhen Ltd 3rd Floor ...

Страница 98: ......

Страница 99: ...ture Operating Storing 0 C to 50 C 32 F to 122 F 40 C to 70 C 40 F to 158 F Relative humidity 5 to 95 non condensing Maximum operation altitude 4000 m 13123 ft Pollution degree 2 for indoor use only Measurement category Not rated for measurement categories II III or IV Overvoltage category I AC version input power 9 V 1 A DC 48 V input power 40 72 V 0 2 A DC 24 V input power 20 32 V 0 4 A ...

Страница 100: ...tage category IIa a AC DC adapter must be a Listed Certified external direct plug in SMPSU Overvoltage Installation category II having reinforced insulation between primary and secondary and suitably rated for the extended BV10 operating environmental conditions altitude temperature and humidity and with output rating voltage and current compatible with above specifications Power Supply Ratingbc I...

Страница 101: ... interface One GigE port Available wavelengths nm 850 1310 and 1550 1000 Base SX 1000 Base LX 1000 Base ZX Wavelength nm 850 1310 1550 Tx level dBm 9 to 3 9 5 to 3 0 to 5 Rx level sensitivity dBm 20 22 22 Maximum reach 550 m 10 km 80 km Transmission bit rate Gbit s 1 25 1 25 1 25 Reception bit rate Gbit s 1 25 1 25 1 25 Tx operational wavelength nm 830 to 860 1270 to 1360 1540 to 1570 Maximum Rx b...

Страница 102: ......

Страница 103: ...g Current ACT Activity ARP Address Resolution Protocol AWG American Wire Gage bit s Bit per second CAGE Commerce And Government Entities CDA Clean Dry Air CIDR Classless Inter Domain Routing CLI Command Line Interface CO Central Office DC Direct Current DCE Data Communications Equipment ...

Страница 104: ...surement Message ESD Electrostatic Discharge EUI EXFO Universal Interfaces FCC Federal Communications Commission FTP File Transfer Protocol GUI Graphical User Interface ICMP Internet Control Message Protocol ID Identification IEC International Electrotechnical Commission in inches IN Input IP Internet Protocol ...

Страница 105: ...nector LED Light Emitting Diode lb Pound LTM Link Trace Message MAC Media Access Control Mbit s Megabit per second MDI Media Dependant Interface straight through Ethernet cable MDIX Media Dependant Interface Crossover crossover Ethernet cable MEG ME Group MEP MEG End Point NATO North Atlantic Treaty Organization nm Nanometer ...

Страница 106: ...C Personal Computer RMA Return Merchandise Authorization rtt Round trip time RX Receive SFP Small Form Factor Pluggable SSH Secure Shell TCP Transport Control Protocol TFTP Trivial File Transfer Protocol TLV Type Length and Value TTL Time To Live TWAMP Two Way Active Measurement Protocol TX Transmit ...

Страница 107: ...Glossary BV10 100 and BV10 1000 101 Acronym List U V UDP User Data Protocol USA United States of America UTP Unshielded Twisted Pairs V Volt VLAN Virtual Local Area Network ...

Страница 108: ...des for 10Base T 100Base TX or 1000Base T connection is 328 feet 100 meters Straight Through Cable 10 100 Mbit s An Unshielded Twisted Pair UTP straight through cable is required to connect a 10Base T 100Base TX BV10 port to a layer 1 or 2 device ex HUB switch Crossover Cable 10 100 Mbit s An Unshielded Twisted Pair UTP crossover cable is required to connect the 10Base T 100Base TX BV10 port to a ...

Страница 109: ...Glossary BV10 100 and BV10 1000 103 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...

Страница 110: ......

Страница 111: ...2 console telnet ssh server enable disable61 console telnet ssh serial idle timeout value_in_seconds 62 exit 45 help 43 interface test laser on off 63 interface test transceiver electrical optical 63 load image 47 logout 45 password clear 61 password set 61 ping 53 reboot 45 server discovery local 54 server discovery network 54 server discovery port 55 server discovery universal 54 server discover...

Страница 112: ...y on BV10 16 Power connection 10 POWER LED 10 20 product identification label 86 R RESET button 21 return merchandise authorization RMA 90 RJ45 port connection 16 S safety caution 3 conventions 3 warning 3 Safety information 5 Safety symbols 8 SC connector cleaner 84 service and repairs 90 service centers 91 SFP 17 85 SFP port connection 17 shipping to EXFO 90 single fiber cleaner 84 Smart Loopbac...

Страница 113: ...Index BV10 100 and BV10 1000 107 W warranty certification 89 exclusions 89 general 87 liability 88 null and void 87 ...

Страница 114: ... Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 嫷䯉年㦘㹡㦘 䓸德咂 年捷ↅ䤓㩟 德㧟㠨 䤓 摞怔 SJ T11363 2006 㪖 屓 䤓棟摞尐㻑ᇭ Part Name 捷ↅ 䱿 Toxic or hazardous Substances and Elements 㦘㹡㦘 䓸德 侯 Lead 杔 Pb Mercury 㻭 Hg Cadmium 椣 Cd Hexavalent Chromium ↆ杻 Cr VI Polybrominated biphenyls 䅃勣啾 PBB Polybromin...

Страница 115: ...MARKING REQUIREMENTS 㪖㽷尐㻑 Product ℶ Environmental protection use period years 䘾 㔳 䞷㦮棟 Logo 㪖 This E 2 product 㦻 EXFO ℶ 10 Batterya 䟄㻯 a a If applicable Ⱁ㨫抑䞷ᇭ 5 ...

Страница 116: ... EXFO ASIA PACIFIC 62 Ubi Road 1 09 01 02 Oxley Bizhub 2 SINGAPORE 408734 Tel 65 6333 8241 Fax 65 6333 8242 EXFO CHINA Beijing Global Trade Center Tower C Room 1207 36 North Third Ring Road East Dongcheng District Beijing 100013 P R CHINA Tel 86 10 5825 7755 Fax 86 10 5825 7722 EXFO SERVICE ASSURANCE 270 Billerica Road Chelmsford MA 01824 USA Tel 1 978 367 5600 Fax 1 978 367 5700 EXFO FINLAND Elek...