RME1-TC User’s Manual - Thermocouple Acquisition Module
Exemys
•
If the device has a configured password, enter the password in the Device Password box.
The manufacturer’s box has a blank.
•
You can type an IP address,
Netmask and Gateway IP Address
or you can click on the “Use
DHCP” check box to make the
device search a DHCP Server. The
RME1-TC has been manufactured
with the DHCP feature activated.
•
You can give the device a personal
name within the field “Host
Name” or you can leave the one
predetermined when
manufactured.
•
Click on the OK button for the
Device Locator send this
information to the device.
•
If the password is not correct, you
will see the message “Error when
changing the configuration”.
Check the equipment to be
configured password. The device will not answer any message sent by the Device Locator
during the first five seconds after an incorrect password. This is to avoid any brute force
method to change the network parameters of the device.
Figure 14 - Device locator
•
If the device does not respond, the Device Locator will show a “No Response from
Device” message. Make sure the device is turned on and connected to the ethernet
network.
•
The Exemys device will reset so the changes in the configuration take effect.
•
If no change is necessary, click on the “Close” button to close the Properties dialog box.
•
After a few seconds the device being reset will answer again to the requests of the
Device Locator software. Click on the “Query network” button to refresh the grid and
make sure the parameters were changed.
c) IP address configuration with serial port
Connecting the serial port of the PC to the serial port of the device , as it was shown in Picture 7,
you can use an utilitarian software such as the Hyperterminal (Microsoft Windows®) to be
connected with the equipment and modify all its parameters . Once the port is opened with the
serial 9600,8,N,1 parameters configuration, the RME1-TC must turn on and type ”cfg” with the
Hyperterminal before 7 seconds have elapsed from the moment it is turned on. You will get
access of the configuration through serial port and will see :