EXCELL PRECISION CO., LTD

.

                   

 

 

SK-VET V1.0                                                                                                                                                      SME300000067 

5

Selectable Weight Units and Piece Unit: 

 

Kilogram 

(kg) 

1 g    =    0.001 kg 

Gram 

(g) 

1 g    =    1 g 

Pound 

(lb) 

1 g    =    0.002204623 lb 

Pound/Ounce (lb, oz) 

1 g    =    0.03527396 oz 

Ounce 

(oz) 

1 g    =    0.03527396 oz 

 

Error Messages: 

 

     

 

The EEPROM memory is not working correctly.

 

       

 

Zero is higher than the zero range when switching the scale on.

 

       

 

Zero is lower than the zero range when switching the scale on.

 

 

 

 

A/D value is unstable. When switching the scale on or pressing the 

  ON/ZERO 

 

key 

      or the 

  TARE 

  key, the A/D value is unstable for at least 20 seconds. 

 

 

 

A/D value is less than -31250. 

 

     

 

A/D IC malfunction (cannot read A/D value). The load cell may not be connected to 

the scale correctly.

   

 

     

 

A/D value is higher than +31250.

 

 

     

 The weight of the object is over the maximum ca 9 divisions. 

 

 

 

 

 

 

       

 

After calibration the displayed resolution is greater than the internal resolution. 

 

 

 

 

 

 

   

 

The gravity value is outside the range 9.772 ~ 9.829.

 

 

 

 

 

 

 

   

 

Error setting.

 

 

 

 

 

 

 

 

 

 

           

 

The weight value is greater than the zero range, when re-zeroing the 

scale.   

 

 

 

 

 

 

 

 

 

     

 The weight value is below the zero range, when re-zeroing the scale. 

 

Содержание SK-VET

Страница 1: ...herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permis...

Страница 2: ......

Страница 3: ...ECIFICATIONS 4 CHAPTER 2 DISPLAY 6 CHAPTER 3 KEYBOARD FUNCTION 7 CHAPTER 4 SERVICE MODE ACCESS 8 4 1 CAPACITY CONFIGURATION 9 4 2 WEIGHT CALIBRATION 12 4 3 FUNCTION SETTINGS 13 4 3 1 Environment Setti...

Страница 4: ...ject the weigh pan to any strong shock loads 4 The load placed on the weigh pan must not exceed the maximum weighing capacity of the scale 5 If the scale is not going to be used for some time please c...

Страница 5: ...aving weight on the pan for long periods of time 4 Once the scale has been switched on it will go through a LCD display test and then re zero to be ready for use 5 The scale requires 15 20 minutes war...

Страница 6: ...ad protection n Dual power source The power source can either be from AC DC or dry batteries Option n LED display backlight Specifications Model Capacity Min Cap Division Resolution SK VET 150 150kg 1...

Страница 7: ...switching the scale on or pressing the ON ZERO key or the TARE key the A D value is unstable for at least 20 seconds A D value is less than 31250 A D IC malfunction cannot read A D value The load cell...

Страница 8: ...O LTD SK VET V1 0 SME300000067 6 CHAPTER 2 DISPLAY TARE Tare indication ZERO Zero indication 1 Kilogram kg the 1st unit indication 2 Pound lb the 2nd unit indication 3 Hold mode indication Low Battery...

Страница 9: ...mpty if the display is not showing zero press this key to zero balance the scale v Zero range 2 of full scale 3 TARE TARE key Press the key to deduct the weight of the container v The tare key is not...

Страница 10: ...nd then the TARE key to enter the service mode the display shows v Set the SWA1 jumper back to the LOCK position when service configuration is completed v If the SWA1 jumper is set to its LOCK positio...

Страница 11: ...9 TARE Confirm enter key HOLD Move the cursor to the right Press the TARE key Input the parameter 01 to enter the capacity configuration Press the TARE key Press the TARE key Press the TARE key The di...

Страница 12: ...he display shows the max capacity of the scale minimum division and the unit weight for 2 seconds Press the TARE key to complete the capacity configuration Input the parameter 00 Example 1 Division si...

Страница 13: ...s 1 3 Parameter descriptions 0 kg 2 lb 5 oz 1 g 4 lb oz Hints and Tips When the first unit is set to lb the second unit will be kg or g For example Select two weight unit kg and lb when choosing kg as...

Страница 14: ...ss the TARE key The display shows the calibration weight value and the weight unit set at the first position When the weight reading is stable the display shows the calibration weight value The scale...

Страница 15: ...ON ZERO Increment digit from 0 to 9 TARE Confirm enter key HOLD Move the cursor to the right Return to the upper menu level Environment settings Buzzer type Press the TARE key Input a parameter 00 01...

Страница 16: ...the weight value is over 1 3 of full capacity Digital switch stable range parameter setting Displays the current setting Use the ON ZERO key to input a parameter Filter parameter setting Displays the...

Страница 17: ...ion sec 4 Less than 1 division sec Re zero range setting The display shows the current setting Use the ON ZERO key to input a parameter Zero range setting The display shows the current setting Press t...

Страница 18: ...t from 0 to 9 TARE Confirm enter key HOLD Move the cursor to the right Press the TARE key Buzzer type The display shows the current setting Press the TARE key Key in the parameter 00 Press the TARE ke...

Страница 19: ...de the display shows v Set the jumper SWA1 back to the LOCK position after completing the calibration v If the jumper SWA1 is set back to the LOCK position during calibration the scale exits the servi...

Страница 20: ...to the weighing mode v The gravity value must lie between those at the Equator and the Polar Regions Gravity value at the equator GE 9 7803184558 m sec2 Gravity value at the polar region GP 9 8321772...

Страница 21: ...when using an ac adaptor as the power source Therefore auto power off is active ONLY when using dry batteries as the power source Auto Backlight Function When the weight is over 10d the backlight is o...

Страница 22: ...on platter is over 10d The scale shows the maximum weight value detected from the continuously changing weight values Press any key to exit the hold function Stable hold mode 1 active when the weight...

Страница 23: ...ng mode a b c d e a Parameters 0 4 to set the stabilization timer 0 0 5 second 1 1 second 2 2 seconds default setting 3 4 seconds 4 8 seconds b c d e Dynamic stabilization range setting 0 100 pre set...

Страница 24: ...LTD SK VET V1 0 SME300000067 22 APPENDIX 7 SEGMENT DISPLAY CHARACTERS Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I...

Страница 25: ......

Отзывы: