Chapter 2 Advanced Functions 

2-1 Advanced Function Setting Table 

Below is an overview of the advanced functions.  For detailed settings refer to the following 
sections: 
 

DISPLAY 

LEVEL 1 FUNCTION 

DISPLAY 

LEVEL 2 FUNCTIONS 

           

Exit the 

ADVANCED 

FUNCTION

 setting mode

--- --- 

     

  

 

Return to the

ADVANCED 

FUNCTION

 setting menu

     

  

 

Automatic backlight 

function setting 

     

    

Automatic power-off  

timer setting 

     

    

Hi/Lo/OK function setting

     

    

Restore the default 

settings 

     

    

Noise filter setting 

   

     

Hold function setting 

            

 

General Function setting 

mode 

   

     

Auto unit weight 

averaging setting 

 

          

External Weight 

Calibration 

--- --- 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание ESW-15

Страница 1: ...erein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied ...

Страница 2: ......

Страница 3: ... 8 1 7 WEIGHT UNIT 8 CHAPTER 2 ADVANCED FUNCTIONS 9 2 1 ADVANCED FUNCTION SETTING TABLE 9 2 2 ADVANCED FUNCTION SETTING WORKFLOW 10 2 3 GENERAL FUNCTION SETTING 11 2 3 1 Automatic Backlight Function Setting 12 2 3 2 Automatic Power off Timer Setting 13 2 3 3 Hi Lo OK Function Setting 14 2 3 4 Restore to the Default Setting 15 2 3 5 Noise Filter Setting 16 2 3 6 Hold Function Setting 17 2 3 7 Auto ...

Страница 4: ...ale 2 Avoid operating the scale in direct sunlight or drafts of any kind 3 If possible avoid connecting the scale to ac power outlet sockets which are adjacent to other appliances to minimise the possibility of interference affecting the performance of the scale 4 Remove any weight that might be on the weigh pan before the scale is switched on and avoid leaving weight on the pan for long periods o...

Страница 5: ... 3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized person No reverse battery or the product will be damaged a Anode of battery should be connected with Anode of product battery usually red cable b Cathode of battery should be connected with Cathode of ...

Страница 6: ...ily replaced Low power indication and auto power off Well designed protection point for transportation Options Double sided display Specifications 1 2 Power Supply Power Supply and Power Consumption DC 6V 4Ah or 6V 7Ah rechargeable battery AC 110V 240V 10 adapter 14 mA system no backlight Single display about 275 hours 28 mA system no backlight double display about 132 hours 19 mA system backlight...

Страница 7: ...wo functions Power On and Zero function OFF KEY When the scale is switched on press the OFF key the scale will switch off TARE KEY The tare function will not operate during the following conditions 1 When the scale powers on if the weight is negative and after a container is placed on the weigh pan if the weight is still below zero 2 The tare value is over the full scale capacity UNITS KEY Press t...

Страница 8: ...ain will cancel the tare and the scale reverts back to zero The Net icon is switched off The tare function can be operated continually to the full weighing capacity of the scale Continual tare operation is adding or removing tare objects on weigh pan and pressing the TARE key each time NET GROSS FUNCTION In the Tare mode the screen displays the Net icon press the NET GROSS key to switch between th...

Страница 9: ...Press ON ZERO key Press ON ZERO key Press UNITS key Press UNITS key Press UNITS key INTERNAL VALUE MODE must hook up Load Cell to test c Press TARE to enter and the display shows internal value d Please check whether the internal value has changed obviously with weight changing e Please check the backlight f Press ON ZERO key to back to the last screen the display shows KEYPAD TEST MODE c Press TA...

Страница 10: ...s lower than the zero range when switching the indicator on Approval models Internal value is below Zero The weight of the object is over 9 divisions of the maximum capacity A D IC value is over the maximum range 1 7 Weight Unit kg 1 g 0 001 kg g 1 g 1 g lb 1 g 0 002204623 lb lb oz 1 g 0 03527396 oz oz 1 g 0 03527396 oz GN 1 g 15 432358 GN dwt 1 g 0 6430149 dwt ct 1 g 5 ct ...

Страница 11: ...g sections DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode Return to theADVANCED FUNCTION setting menu Automatic backlight function setting Automatic power off timer setting Hi Lo OK function setting Restore the default settings Noise filter setting Hold function setting General Function setting mode Auto unit weight averaging setting External Weight Cali...

Страница 12: ...d Function setting mode The LCD shows Overall workflow of the Advanced Function setting mode General Function setting mode External Weight Calibration Exit the Advanced Function setting mode Refer to the following sections for the detailed operation procedures of each function setting Press UNITS key Press ON ZERO key Press UNITS key Press UNITS key Press ON ZERO key Press ON ZERO key ...

Страница 13: ...ic Power off Timer Settings Hi Lo OK Settings Restore the Default Settings Noise Filter Settings Hold Function Settings Auto Unit Weight Averaging Setting Refer to the following sections for detailed operation procedures of each setting Press TARE key Use the keys to select the function Key in 00 and press TARE key to return to the Advanced function setting menu ON ZERO key Upward key from 0 to 9 ...

Страница 14: ...ht function When the weight is over 10d the display backlight will be on After the weight is stable for 10 seconds or when the scale returns to zero the display backlight switches off DISPLAY ACTIONS NOTE Key in the parameter 00 Press TARE key Use ON ZERO orUNITS key to select function on or off Press TARE key Press TARE key to complete the general setting procedures LCD displays the last status ...

Страница 15: ... from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET GROSS key Move the cursor to left Automatic power off timer setting Use ON ZERO or UNITS key to key in parameter 0 No auto power off 1 When the scale is idle for 1 minute the scale automatically switches off 2 When the scale is idle for 2 minutes the scale automatically switches off 9 When the scale is idle for 9...

Страница 16: ... a b c The definition of a b c positions a 1 beep sound on 0 beep sound off b 1 beep sound on when stable 0 beep sound on when unstable c 1 beep sound on when the weight is between high and low limits 0 beep sound on when the weight is not between high and low limits and higher than 10d ON ZERO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET GROS...

Страница 17: ...ternal 4 Sampling setting for the counting function Setting is only available for non approval models ACTIONS DISPLAY NOTE Return Cancel the restoration Restore to the default setting ON ZERO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET GROSS key Move the cursor to left Press TARE key Use ON ZERO or UNITS keys to select return or format Press ...

Страница 18: ...ing LCD displays the last parameter setting Filter parameter setting Use ON ZERO or UNITS keys to key in the parameters Default setting 5 Parameter 0 9 the larger the number the faster the filter response Fast response can lead to weight instability Digital switch Stabilization range setting Use ON ZERO or UNITS keys to key in the parameters Default setting 0 Parameter 0 9 the larger the number th...

Страница 19: ...ws the current weight value When the weight returns to zero 10d the hold mode is cancelled automatically ACTIONS DISPLAY NOTE Hold function setting Use ON ZERO or UNITS keys to key in the parameters Default setting 0 0 Hold function disabled 1 Peak hold mode 2 Stable hold 1 mode 3 Stable hold 2 mode Hold function setting LCD displays the last parameter setting ON ZERO key Upward key from 0 to 9 UN...

Страница 20: ... right NET GROSS key Move the cursor to left Auto unit weight averaging setting Use ON ZERO or UNITS keys to key in the parameters Default setting 0 0 Auto unit weight averaging 1 Non auto unit weight averaging Auto unit weight averaging setting LCD displays the last parameter setting DISPLAY ACTIONS NOTE Use ON ZERO or UNITS key to key in the parameters Press TARE key to complete the general sett...

Страница 21: ...maximum capacity of 1st unit and the unit The digit on the right side keeps flashing The scale is calculating the internal value of the zero point After stabilization the LCD shows the calibration weight value Press TARE key When the digit on the right flashes ensure that the weigh pan is empty Then Press the TARE key After stabilization Place the displayed weight on the weigh pan Press the TARE k...

Страница 22: ...0306 20 EXCELL PRECISION CO LTD Appendix 1 7 Segment Display Characters Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z ...