02005316
ZSME3000000306
14
EXCELL PRECISION CO., LTD.
2-3-3 Hi/Lo/OK Function Setting
Select in the General Function setting mode to set the
Hi/Lo/OK function. This function is available in all unit modes. In one specific unit mode,
enter to set the Hi/Lo/OK values.
When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled.
DISPLAY
ACTIONS
NOTE
LCD displays the last status
LCD displays the last status
.
lb
LCD displays the last status
.
lb
.
lb
.
lb
Alarm setting
(a) (b) (c)
The definition of a, b, c positions:
(a)
⇒
1 = beep sound on
0 = beep sound off
(b)
⇒
1 = beep sound on when stable
0 = beep sound on when unstable
(c)
⇒
1 = beep sound on when the weight is
between high and low limits
0 = beep sound on when the weight is
not between high and low limits and
higher than 10d
ON/ZERO
key
⇒
Upward key (from 0 to 9)
UNITS
key
⇒
Downward key (from 9 to 0)
TARE
key
⇒
Move the cursor to right
NET/GROSS
key
⇒
Move the cursor to left.
Key in the desired
high limit value
Key in the parameter
setting for alarm
Press
TARE
key
Press
TARE
key
Key in the desired
low limit value
Press
TARE
key
Press
TARE
key
Key in the parameter “00”
Press
TARE
key to complete
the general setting procedures
Содержание ESW-15