EXCELL PRECISION CO., LTD.
02036XXX
ZSME300000422
14
RS-232 Data Format
Command mode (r n P 0)
Command
Function
Return message definition
C
T <CR> <LF>
Clear tare
N P <CR> <LF> already pre-tared
C T <CR> <LF> successful
M T <CR> <LF>
Tare
N P <CR> <LF> already pre-tared
M T <CR> <LF> successful
N S <CR> <LF> unstable
M Z <CR> <LF>
Zero
N P <CR> <LF> already pre-tared
N T <CR> <LF> already tared
M Z <CR> <LF> successful
N Z <CR> <LF> outside zero range
N S <CR> <LF> unstable
R W <CR> <LF>
Read Weight
Return weight format as (r n p1)
P
T
,
0
0 0 1 0 0 <CR> <LF> Set pre-tare
N O <CR> <LF>
exceed number of
digits
L
O
,
0
0 0 1 0 0 <CR> <LF> Set low limit
N N <CR> <LF> non-numeric value
H
I
,
0
0 0 1 0 0 <CR> <LF> Set high limit
N G <CR> <LF> over max weight
N D <CR> <LF>
Increment d is
incorrect
Stable transmission (
r n P 1
), Continuous (
r n P 2
), Press
key to transmit (
r n P 8
)
1. gram as weight unit
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 g
HEAD , HEAD , ± DATA UNIT CR LF
2. kg or lb as weight unit
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 kg/lb
HEAD , HEAD , ± DATA UNIT CR LF
HEAD1 ( 2 BYTES )
HEAD2 ( 2 BYTES )
OL - Overload , Under load TR - TARE Mode
ST - Display is Stable
NT - NET Mode
US - Display is Unstable
GS - GROSS Mode
DATA ( 7 or 8 BYTE )
2B ( HEX ) = “
+
” ( PLUS)
2D ( HEX ) = “
–
” ( MINUS )
2E ( HEX ) = “
.
” ( DECIMAL POINT )
UNIT ( 2
、
3 or 4 BYTE )
kg =
6B ( HEX )
;
67 ( HEX )
lb =
6C( HEX )
;
62 ( HEX )
tl.T
=
74 ( HEX )
;
6C ( HEX )
;
2E ( HEX )
;
54 ( HEX )
hkg =
68 ( HEX )
;
67 ( HEX )
viss =
76 ( HEX )
;
69 ( HEX )
;
73 ( HEX )
;
73 ( HEX )