Chapter 2 General Operation Description 

2-1 Backlight Function 

Press 

  key to select the display backlight mode:   

bL. Auto 

 

“Auto Backlight” mode. When the weight is over 10d or any key is pressed, the 

display backlight will be switched on. When the weight returns to zero (the weight on 

platform is less than 10d), the display backlight will switch off after 10 seconds. 

bL. On 

 Display backlight is on all the time. 

bL. oFF 

 Display backlight is off. 

 

2-2 Weighing Mode 

 

2-2-1 Units Selection 

(not available in 4 key model)

 

1.  After indicator is turned on, use UNITS key to select a unit from kg, lb, tael or viss, as 

the screen indicated. 

2.  The selected unit will be memorized when you turn the indicator off. And the 

memorized unit will appear after you turn on the indicator next time.     

2-2-2 Zero Function 

              Press 

  key to re-zero the display with no load on the platter. When zero is set, the 

(

) symbol will be displayed. 

2-2-3 Tare Function     

     

1. 

When the weight of the container is unknown 

(

 Place the container on the platter, after stable and press 

 

key, the weight value 

returns to zero and net indication (

) is on. 

           

 Place goods into the container, then the indicator shows the net weight of goods. 

           

 Clear tare value 

             

 

When removing the container and goods, the display shows the negative weight value 

of the container. Then press 

  key to clear tare value. The indicator returns to 

zero and net indication (

) is on. 

           

 Recall tare value 

Press 

  then 

 

key

 

 the display shows tare value 

 

 

Multiple tare operation 

 Users can continuously increase or decrease the tare value by 

pressing the

 

 

key.

 

 

The total tare value (tare value + pre-set tare value) can equal the full capacity of the 

indicator.

 

     

2. 

When the weight of the container is known 

(

)

   

 

 Press 

 

key and the display shows

 

 

 

.

 

 

.   

Use 

  and 

  keys to input weight value of the container. After finishing the 

procedures, the net indication 

(

and pretare (PT) indication 

” is on. 

 Place goods into the container, then the indicator shows the net weight of goods. 

 Clear pretare value 

                Press 

  then 

  key, and then press 

  key to clear pretare value. 

                When indicator returns to zero, net indication (

) and pretare (PT) 

indication “

” are 

Содержание AWH3

Страница 1: ...n is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission Th...

Страница 2: ...NOT AVAILABLE IN 4 5 KEY MODELS 10 2 3 1 Sampling 10 2 3 2 Check Weighing 11 2 3 3 Totalizing 11 CHAPTER 3 GENERAL FUNCTION SETTING 11 3 1 F4 CHECK WEIGHING CONFIGURATIONS 12 3 2 F5 RS 232 OUTPUT SET...

Страница 3: ...utions for Use 1 Please operate or charge the scale in an open area Do not squeeze the power cord to avoid wire on fire 2 Please keep scale in a cool and dry place Do not store under high temperatures...

Страница 4: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized p...

Страница 5: ...cale 4 Check Weighing function for high limit and low limit and OK range 5 5 HOLD functions including animal scale HOLD 6 Depending on actual space a RS232 card and or a relay card can be installed 1...

Страница 6: ...ity for weight check or quantity check TGT SET Accumulate weight or quantity Tare to deduct the container weight TARE Set preset tare Recall the totalization value preset value and pre tare value RE C...

Страница 7: ...weight accuracy 1 5 Error Messages oL Weight exceeds 9d of maximum capacity d division E1 Zero value after power on is over 10 FS E2 Zero value after power on is less than 10 FS E4 Unstable zero retur...

Страница 8: ...When the weight of the container is unknown Place the container on the platter after stable and press key the weight value returns to zero and net indication is on Place goods into the container then...

Страница 9: ...r gross value In tare mode key is able to work When it displays all keys are disable except 2 2 5 Check Weighing Mode 4 5 key models need to set through F4 1 Preset High limit Low limit and Beeper val...

Страница 10: ...xed as follows When over Low Limit the beeper beeps and is off Whether stable or not the beeper beeps and LCD indication is on Warning device setting not available in 4 5 key models Set HI value and v...

Страница 11: ...Refer to F5 setting 2 Clear Totalized Weight Values not available in 4 5 key models Press then key to clear all totalized weight values When changing between weighing and counting mode or selecting we...

Страница 12: ...ting down to zero press and hold key until the display shows the software version number 02018 Release the key the scale enters into the configuration setting mode and display F0 key upward key key do...

Страница 13: ...table the beeper beeps and the indications are on 1 After stable the beeper beeps whether stable or not the indications are on 2 whether stable or not the beeper beeps and the indications are on 3 ope...

Страница 14: ...zed complete format r n P 5 Stable transmission in totalizing mode Same format as r n P 3 r n P 6 Press key to transmit simple free format Please refer to F14 r n P 7 Press key to transmit complete Fr...

Страница 15: ...I 0 0 0 1 0 0 CR LF Set high limit N G CR LF over max weight N D CR LF Increment d is incorrect 1 1 b CR LF Set buzzer 1 1 b CR LF successful Stable transmission r n P 1 Continuous r n P 2 Press key...

Страница 16: ...d simple format r n P 3 S N WT UNIT kg lb 0001 1 0000 Press or key 0002 1 0000 Press or key 0003 1 0000 Press or key 0004 1 0000 Press or key 0005 1 0000 Press or key 0005 5 0000 Press twice to print...

Страница 17: ...e stable Weight zero point Weight 20 weighing units i e 5 x Weight 1 weighing unit Beeper beeps twice and printing data stable weight compliant with conditions on the left is ready to be sent 2 Just r...

Страница 18: ...ansmit when weight change 10d Transmit when weight change 10d Print TOTAL and clears totalized values r n p 4 Press key to transmit totalized complete format Transmit when weight change 10d Transmit w...

Страница 19: ...value is transmitted After return to zero transmit next stable weight s weight value only r n p 15 Enter serial number reply serial number weight Enter serial number and put the weight on Once it is s...

Страница 20: ...e press any key except the key hold 3 After the scale is stabilized the scale will automatically hold the display value not changeable due to external variables After zero return or weight is less tha...

Страница 21: ...and scale enters hold mode This whole hold mode entry and exit process will repeat continuously 3 6 F11 ID Code Setting must be used with r n P 1 r n P 2 r n P 8 of F5 Press key or key to select F11...

Страница 22: ...ress key Print key setting Use and to set 0 2 Default setting 0 P r F 0 If weight variation is beyond 1d 10d key print totalized weight Otherwise print current weight d division P r F 1 key print curr...

Страница 23: ...nds to setup 1 second 0 0 0 0 0 0 Use key to enter 12 digit Part number 0 0 0 0 0 0 1 second 0 0 0 0 0 0 Use key to enter 10 digit Serial number 0 0 0 0 After power off S N will reset as 1 P N will be...

Страница 24: ...to get in checkweighing mode to set the HIGH and LOW limit points Between HIGH and LOW limits are OK range If the weight is below LOW limit the data will output in LOW port If the weight is between H...

Страница 25: ...5 J1 J2 SHORT 4 Configuration OK High and Low can be set to NO normally open Type A or NC normally closed Type B The default value is NO normally open Type A OK High and Low are NO normally open Type...

Страница 26: ...Code 01 Read Function Code 05 and 15 Write Modbus SCALE Modbus SCALE Output Modbus SCALE Input 40004 40005 As display value 00000 Stable status 01000 Zero 00001 Zero status 01001 Function Code 06 and...

Страница 27: ...dbus SCALE Modbus SCALE Output Modbus SCALE Input 40005 40006 As display value 00001 Stable status 01001 Zero 00002 Zero status 01002 Function Code 06 and 16 Write 00003 Gross 01003 Tare 41001 41002 P...

Страница 28: ......

Отзывы: