EXCELL PRECISION CO., LTD.
0201813X
ZSME300000366
10
3. Clearing Check-weighing Values
(not available in 4/5/10 key models)
Press
key then press
key, and then press
key
Recall
“Low limit
value
”. Then press
key again
Clear
“High limit value” and “Beeper value”
Press
key then press
key 6 times continuously
Clear all values.
2-2-6 Totalizing
(not available in 4/5 key models)
1. Weight Totalizing
Place goods on the platter, after stable and press
key to save the weight value.
Then the display shows the total number of additions and the totalized weight value.
And the (M+) indication “
” will flash on the display. The indicator will recover to show
the weight value of the goods on the platter after 3 seconds a
nd the (M+) indication “
”
is on.
The indicator allows the next totalizing operation, even when the weight value does not
return back to zero. The
key is functional, when the weight value changes by more
than 10d. The indicator will save the totalized weight value after the weight is stable.
The indicator can totalize positive or negative weight but
can’t do both at the same time.
The totalized weight store must be reset to zero before it is possible to select positive or
negative totalizing mode.
The totalizing function can be used up to a maximum of 9999 times before it must be
reset. The totalizing display is limited to 6 digits maximum.
When totalizing, RS-232 will also output. ( Refer to F5 setting)
2. Clear Totalized Weight Values
(not available in 4/5 key models)
Press
then
key to clear all totalized weight values.
When changing between weighing and counting mode, or selecting weighing unit, the
indicator will automatically clear all the totalized weight values.
The indicators will automatically clear all the totalized weight values after turning on.
3. Recall Totalized Weight Values
(not available in 4/5 key models)
Press
key to display the total number of additions and the totalized weight value.
And the (M+) indication
“
” will flash on the display. The indicator will return to the
weighing mode after 3 seconds.
The indicator will not display the negative sign “-” for negative totalized weight values
when recalling a totalized weight value, but when printing,
the negative sign “-” will be
printed out (transmitted serially) for each negative weight and negative totalized weight.
2-3 Counting Function
(not available in 4/5 key models)
2-3-1 Sampling
Press
key to select sample quantity from 10, 20, 50,100
Select sample quantity and then place samples on the platter, and then press
key,
the display shows “
”.
After stable, the scale enters into counting mode and the display shows sample quantity.
Sample Too Small (
.
.
.
.
.
.
.
.
.
.
)
Sample is less than 20 divisions.
Unit Weight Too Small (
Pcs
)
Unit weight is less than 0.2 division.
(0.1 d for Brazil regulation)
When sampling, the above two symbols indications are on. Under such conditions, the
scale can still work, but may result in lower count precision.
When using 2-segment weighing mode, the above two symbol indications change to
Содержание AWH3