Installing and changing the saw blade 

 

WARNING

: To reduce the risk of injury, turn the 

unit off and disconnect it from the power source before 
installing and removing accessories, before adjusting 
or when making repairs. An accidental start-up can 
cause injury. 

Remove the power plug from the socket. 

Remove the blade guard cover (FIGURE S / 1) by 
opening the blade guard screw (FIGURE S / 2).  
Press the spindle- lock button (FIGURE A / 12) and 
simultaneously rotate the blade by hand until the 
spindle-lock button drops a further distance of about 7 
mm. Now the rotation of the blade is prevented.  
Use the 5mm allen key to open the blade attachment 
screw.  
Remove the securing screw and washer (FIGURE S / 
3), the outer blade flange (FIGURE S / 4) and the blade 
(FIGURE S / 5). 

Before installing a new blade, check that both blade 
flanges are clean. Place a new or sharpened blade on 
the back flange (FIGURE S / 6), so that the marked 
side of the blade is facing outwards and the arrows on 
the blade are facing in the same direction as the 
rotation direction markings on the inside of the blade 
cover. Ensure that the new blade goes right to the 
bottom on the back blade flange. Put the outer blade 
flange, and the securing bolt back in place. Press the 
spindle lock button and tighten the blade securing nut. 
Put the blade guard cover back in place and tighten the 
blade cover bolt. 

 

 

FIGURE S

  

Maintenance and servicing instructions 

Remove the power plug from the socket before 
servicing or cleaning the pipe saw. All maintenance 
operations carried out on the pipe saw's electrical 
components must be carried out by an approved 
service center or engineer. 

Blade 

Check the condition of the blade. Replace a bent, blunt, 
or otherwise damaged blade with a new one. Using a 
blunt blade can overload the pipe saw's electric motor 
and gearbox. When you notice that the blade is blunt 
do not continue cutting with it, as the blade may 
become so badly damaged that it will not be worth 
sharpening. A blade in sufficiently good condition can 
be sharpened a few times by a professional sharpening 
company. Diamond X Discs cannot be sharpened 

Gripper unit 

Clean the gripper unit regularly with compressed air. 
Lubricate the gripper's wheel axles (FIGURE T / 1 and 
3) and its joints (FIGURE T / 2). Clean and lubricate 
also the gripper's trapezoidal screw and the two 
adjusting nuts on it (FIGURE T / 4). 

Blade guard 

 WARNING

: Regularly check the correct function 

of the lower blade guard. To check the function, first 
disconnect the tool from power source and then lift the 
lower blade guard to upper position by hand. After 
releasing the blade cover, it should return to lowest 
position without any delay or friction. 
When you have cut plastic pipes and then intend to 
start cutting metal pipes always clean the inside of the 
blade guards. Hot metal particles originating from metal 
cutting will heat up plastic particles, which may release 
toxic smoke. Make it a rule to clean the blade guard 
regularly and pay special attention to keep the moving 
blade guard movement from becoming obstructed. 
Lubricate the axis of the moving blade guard regularly. 

As an extra equipment you can buy outer blade 
guard with connection for vacuum cleaner. For 
extra equipment see page 18. 
Motor 

Keep motor air vents clean to allow free airflow. 

 
FIGURE T

 

Содержание PipeCut 220 Pro Series

Страница 1: ...are the original instructions All instructions are available on web site exacttools com manuals Patents US 7 257 895 JP 4010941 EP 1301311 FI 108927 KR 10 0634113 EN Operating Instructions PipeCut 22...

Страница 2: ...Intentionally left blank...

Страница 3: ...for cutting Cast or Ductile Iron only Exact DIAMOND X discs cannot be sharpened Declaration of Conformity We declare under our sole responsibility that the pipe cutting machines Exact PipeCut 220 Pro...

Страница 4: ...locking screws 2pcs 8 Cutting depth adjusting wheel 9 Gripper adjusting wheel 10 Handle 11 Blade guard screw 12 Blade lock pin 13 Rating plate 14 Motor unit 15 Blade RPM selector switch 16 Motor unit...

Страница 5: ...Cutting around the pipe 11 Overload protection and RPM adjustment 13 Explanation if indicator lights 13 Improving possible misalignment of the cut 13 Cutting result adjustment on Exact PipeCut 14 220...

Страница 6: ...tion Yes Reduced starting current Yes Vibration Ah 2 5 m s2 Vibration uncertainty K 1 5 m s2 LpA sound pressure 96 dB A KpA sound pressure uncertainty 3 dB A LWA acoustic power 107 dB A KWA acoustic p...

Страница 7: ...are not to be expected for system impedances below 0 36 ohm Noise vibration Information The vibration emission level given in this information sheet has been measured in accordance with a standardize...

Страница 8: ...nintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch...

Страница 9: ...ligned saw blade causing an uncontrolled saw to lift up and out of the workpiece toward the operator when the blade is pinched or jammed tightly by the kerf closing down the blade stalls and the motor...

Страница 10: ...e blade is not clamped between the ends of the pipes Support the pipe to cut securely Pipe supports are more reliable for holding the pipe than bare hands Make sure that the pipe to be cut is empty Ta...

Страница 11: ...pipe Check that all support wheels contact the pipe adjust if required e g with pieces of lumber FIGURE B1 When cutting short and light weight pipes place the supports so that the cutting point is ou...

Страница 12: ...ng piercing the pipe must not rotate Look at the UNLOCK SWITCH during the piercing operation The yellow mark on UNLOCK SWITCH disappears FIGURE E 1 2 when the pipe saw is locked in the sawing position...

Страница 13: ...vent correct function of blade cover When the pipe is cut off push the UNLOCK SWITCH forward until the yellow mark is visible and the locking is released FIGURE I1 2 Now raise the motor unit to starti...

Страница 14: ...the codes To be able to read the codes the main switch needs to be kept connected List of error codes can be found below No of blinks Error description 1 Mains frequency too high 2 Mains frequency to...

Страница 15: ...turn the central part of the adjustment wheel so that d is smaller FIGURE M a If the laser line is to the right of the marking FIGURE K b turn the central part of the adjustment wheel so that d is la...

Страница 16: ...t wheel For higher setting smaller cutting depth turn the adjustment wheel counter clockwise FIGURE P 1 For lower setting deeper cutting depth turn the adjustment wheel clockwise FIGURE P 2 After the...

Страница 17: ...pipe saw s electrical components must be carried out by an approved service center or engineer Blade Check the condition of the blade Replace a bent blunt or otherwise damaged blade with a new one Usi...

Страница 18: ...the operating safety and servicing instructions provide in these instructions 5 The Exact PipeCut Saw has been delivered to an Authorized Warranty Repair Center within the warranty period NOTICE The E...

Страница 19: ...ndard vacuum cleaners Recommended to use when cutting plastic or materials that produce dust FIGURE U Blade suitability Exact TCT Suitable for cutting steel and all kinds of plastic pipe material Exac...

Страница 20: ...als which can be cut by Exact 220 Pro Series machine 220 Pro Series Steel pipes Max pipe wall thickness 16 mm 0 6 230V 0 5 12mm 120V Stainless steel pipes Max pipe wall thickness 16 mm 0 6 230V 0 5 12...

Отзывы: