background image

 

Design and function 

Transport and installation 

 

099-003694-EW501 

04.05.2017

 

9

 

 

Design and function 

 

 

 WARNING 

 

Harmful electrode material! 
Electrodes may contain harmful substances! 

•  Observe the instructions by the electrode manufacturer! 

 

 

 CAUTION 

 

Open infeed channel! 
If the infeed channel is left open, chips and dirt particles can be expelled from the 
channel when the grinding disk is running and might get into the eyes or be breathed 
in! 

•  Place the electrode holder in the infeed channel before switching on. 
•  Allow the grinding disk to come to a stop after switching off before removing the electrode 

holder from the infeed channel. 

 

Starting with electrode against grinding disc! 
If the grinder is started while the electrode lies against the grinding disc, the electrode 
can jam and cause damage to the disc, the machine and people! 

•  When starting the grinder, make sure the electrode does not lie against the grinding disc! 
•  Before starting the grinder, check the electrode position through the inspection window! 

 

 

If too much pressure is exerted from the electrode onto the grinding disk, the electrode may 
overheat and become annealed. An annealed electrode can become unusable and damage the 
machine! 
•  Do not press the electrode too forcefully against the grinding disk! 
•  Turn the electrode evenly during the grinding process! 

 
 

 

5.1 

Transport and installation

 

 

 

 CAUTION 

 

Risk of accidents due to supply lines! 
During transport, attached supply lines (mains leads, control cables, etc.) can cause 
risks, e.g. by causing connected machines to tip over and injure persons! 

•  Disconnect all supply lines before transport! 

 

 

5.1.1 

Ambient conditions

 

 

 

Unusually high quantities of dust, acid, corrosive gases or substances may damage the 
equipment. 
•  Avoid high volumes of smoke, vapour, oil vapour and grinding dust! 
•  Avoid ambient air containing salt (sea air)! 

 
 

 

Insufficient ventilation results in a reduction in performance and equipment damage. 
•  Observe the ambient conditions! 
•  Keep the cooling air inlet and outlet clear! 
•  Observe the minimum distance of 0.5 m from obstacles! 

Содержание TGM 40230 Porta

Страница 1: ...instructions EN Electrode grinding machine TGM 40230 Porta 230V 50Hz 099 003694 EW501 04 05 2017 Register now and benefit Jetzt Registrieren und Profitieren www ewm group com For details visit www ewm...

Страница 2: ...ervice department on 49 2680 181 0 A list of authorised sales partners can be found at www ewm group com Liability relating to the operation of this equipment is restricted solely to the function of t...

Страница 3: ...4 Machine description 8 5 Design and function 9 5 1 Transport and installation 9 5 1 1 Ambient conditions 9 5 1 1 1 In operation 10 5 1 1 2 Transport and storage 10 5 1 2 Presets 10 5 1 2 1 Topping u...

Страница 4: ...erved to prevent serious and even fatal injuries Safety notes include the WARNING keyword in the heading with a general warning symbol The hazard is also highlighted using a symbol in the page margin...

Страница 5: ...wait 4 s activate Signal light flashes red Interruption in the menu display other setting options possible Tool not required do not use Tool required use 2 3 General WARNING Risk of accidents due to...

Страница 6: ...The regulations regarding occupational safety and accident prevention for the respective country Check at regular intervals that users are adhering to the safety regulations in their work Check the ma...

Страница 7: ...www ewm group com 3 2 2 Declaration of Conformity The labelled machine complies with the following EC directives in terms of its design and construction Machine directive Low Voltage Directive LVD Ele...

Страница 8: ...pection glass 3 Filling hose 4 Mains connection cable 5 Dust container 6 Indication of correct liquid level 7 Machine table 8 Depth gauge setting bolt 9 Collet chuck 10 Electrode holder Area of applic...

Страница 9: ...sc Before starting the grinder check the electrode position through the inspection window If too much pressure is exerted from the electrode onto the grinding disk the electrode may overheat and becom...

Страница 10: ...C 5 1 1 2 Transport and storage Storage in an enclosed space temperature range of the ambient air 30 C to 70 C Relative air humidity Up to 90 at 20 C 5 1 2 Presets CAUTION Complete assembly The machi...

Страница 11: ...3 Filling hose 4 Inspection glass 5 Indication of correct liquid level 6 Dust container 7 Drain thread 8 Machine table Unfasten the locking screw from the drain thread Manually screw the duct collecto...

Страница 12: ...jury Only use genuine collet chucks Only use collet chucks that match the relevant electrode diameter Figure 5 2 Item Symbol Description 0 1 Electrode 2 Collet chuck 3 Electrode holder Area of applica...

Страница 13: ...is damaged Use original grinding discs only Check that the on off switch is in the 0 position Connect the machine to the power supply Check through the inspection glass that the electrode is not posi...

Страница 14: ...disconnected Disconnect all mains connections and supply lines CAUTION Grinding dust Grinding dust may get into the eyes during cleaning Grinding liquid residue can enter the bloodstream via surface s...

Страница 15: ...fit the inspection glass and inspection glass frame using the screws Make sure the sealing ring fits tightly between casing and inspection glass 6 2 Replacing the grinding disk Disconnect the grinding...

Страница 16: ...230 PORTA Mains cable length 2 m Output 380 W Mains connection EN 50144 230 V 50 60 Hz Speed 8500 rpm Diamond disk diameter 40 mm Grinding speed 44 m s Grinding angle setting 7 5 90 Grinding liquid fi...

Страница 17: ...ers 098 003697 00000 COL Porta Handy 1 2 mm Collet chuck for EWM tungsten electrode grinders 098 003698 00000 COL Porta Handy 1 6 mm Collet chuck for EWM tungsten electrode grinders 098 003674 00000 C...

Страница 18: ...Appendix A Overview of EWM branches 18 099 003694 EW501 04 05 2017 9 Appendix A 9 1 Overview of EWM branches...

Отзывы: