background image

 

Intended use 

Applications 

 

099-003694-EW501 

04.05.2017

 

7

 

 

Intended use 

 

 

 WARNING 

 

Hazards due to improper usage! 
The machine has been constructed to the state of the art and any regulations and 
standards applicable for use in industry and trade. It may only be used for the welding 
procedures indicated at the rating plate. Hazards may arise for persons, animals and 
material objects if the equipment is not used correctly. No liability is accepted for any 
damages arising from improper usage! 

•  The equipment must only be used in line with its designated purpose and by trained or 

expert personnel! 

•  Do not improperly modify or convert the equipment! 

 

3.1 

Applications 

Grinder for TIG electrodes. 

3.2 

Documents which also apply 

3.2.1 

Warranty 

 

 

For more information refer to the "Warranty registration" brochure supplied and our information 
regarding warranty, maintenance and testing at 

www.ewm-group.com

! 

 

3.2.2 

Declaration of Conformity 

 

 

 

The labelled machine complies with the following EC directives in terms of its design and 
construction: 

•  Machine directive 
•  Low Voltage Directive (LVD) 
•  Electromagnetic Compatibility Directive (EMC) 
•  Restriction of Hazardous Substance (RoHS) 

 

In case of unauthorised changes, improper repairs, non-compliance with specified deadlines for "Arc 
Welding Equipment 

– Inspection and Testing during Operation", and/or prohibited modifications which 

have not been explicitly authorised by EWM, this declaration shall be voided. An original document of the 
specific declaration of conformity is included with every product. 

 

3.2.3 

Service documents (spare parts) 

 

 

 WARNING 

 

Do not carry out any unauthorised repairs or modifications! 
To avoid injury and equipment damage, the unit must only be repaired or modified by 
specialist, skilled persons! 
The warranty becomes null and void in the event of unauthorised interference. 

•  Appoint only skilled persons for repair work (trained service personnel)! 

 

Spare parts can be obtained from the relevant authorised dealer. 

 

Содержание TGM 40230 Porta

Страница 1: ...instructions EN Electrode grinding machine TGM 40230 Porta 230V 50Hz 099 003694 EW501 04 05 2017 Register now and benefit Jetzt Registrieren und Profitieren www ewm group com For details visit www ewm...

Страница 2: ...ervice department on 49 2680 181 0 A list of authorised sales partners can be found at www ewm group com Liability relating to the operation of this equipment is restricted solely to the function of t...

Страница 3: ...4 Machine description 8 5 Design and function 9 5 1 Transport and installation 9 5 1 1 Ambient conditions 9 5 1 1 1 In operation 10 5 1 1 2 Transport and storage 10 5 1 2 Presets 10 5 1 2 1 Topping u...

Страница 4: ...erved to prevent serious and even fatal injuries Safety notes include the WARNING keyword in the heading with a general warning symbol The hazard is also highlighted using a symbol in the page margin...

Страница 5: ...wait 4 s activate Signal light flashes red Interruption in the menu display other setting options possible Tool not required do not use Tool required use 2 3 General WARNING Risk of accidents due to...

Страница 6: ...The regulations regarding occupational safety and accident prevention for the respective country Check at regular intervals that users are adhering to the safety regulations in their work Check the ma...

Страница 7: ...www ewm group com 3 2 2 Declaration of Conformity The labelled machine complies with the following EC directives in terms of its design and construction Machine directive Low Voltage Directive LVD Ele...

Страница 8: ...pection glass 3 Filling hose 4 Mains connection cable 5 Dust container 6 Indication of correct liquid level 7 Machine table 8 Depth gauge setting bolt 9 Collet chuck 10 Electrode holder Area of applic...

Страница 9: ...sc Before starting the grinder check the electrode position through the inspection window If too much pressure is exerted from the electrode onto the grinding disk the electrode may overheat and becom...

Страница 10: ...C 5 1 1 2 Transport and storage Storage in an enclosed space temperature range of the ambient air 30 C to 70 C Relative air humidity Up to 90 at 20 C 5 1 2 Presets CAUTION Complete assembly The machi...

Страница 11: ...3 Filling hose 4 Inspection glass 5 Indication of correct liquid level 6 Dust container 7 Drain thread 8 Machine table Unfasten the locking screw from the drain thread Manually screw the duct collecto...

Страница 12: ...jury Only use genuine collet chucks Only use collet chucks that match the relevant electrode diameter Figure 5 2 Item Symbol Description 0 1 Electrode 2 Collet chuck 3 Electrode holder Area of applica...

Страница 13: ...is damaged Use original grinding discs only Check that the on off switch is in the 0 position Connect the machine to the power supply Check through the inspection glass that the electrode is not posi...

Страница 14: ...disconnected Disconnect all mains connections and supply lines CAUTION Grinding dust Grinding dust may get into the eyes during cleaning Grinding liquid residue can enter the bloodstream via surface s...

Страница 15: ...fit the inspection glass and inspection glass frame using the screws Make sure the sealing ring fits tightly between casing and inspection glass 6 2 Replacing the grinding disk Disconnect the grinding...

Страница 16: ...230 PORTA Mains cable length 2 m Output 380 W Mains connection EN 50144 230 V 50 60 Hz Speed 8500 rpm Diamond disk diameter 40 mm Grinding speed 44 m s Grinding angle setting 7 5 90 Grinding liquid fi...

Страница 17: ...ers 098 003697 00000 COL Porta Handy 1 2 mm Collet chuck for EWM tungsten electrode grinders 098 003698 00000 COL Porta Handy 1 6 mm Collet chuck for EWM tungsten electrode grinders 098 003674 00000 C...

Страница 18: ...Appendix A Overview of EWM branches 18 099 003694 EW501 04 05 2017 9 Appendix A 9 1 Overview of EWM branches...

Отзывы: