Design and function
Interfaces for automation
90
099-000118-EW501
24.11.2017
5.13.7.10 Specifying max. no. of accessible JOBs
This function can be used to specify the maximum number of JOBs which can be retrieved from the free
memory. The factory setting is for 10 JOBs to be accessible on the welding machine, but this figure can
be increased to up to 128 if required.
The first JOB in the free memory is JOB 129. With the factory setting of 10 JOBs, this equates to JOB
numbers 129 to 138. The first JOB can be set as required.
The following graphic gives an example with the settings for max. JOBs available = 5 and first available
JOB = 145. This gives the available JOBs 145 to 150.
Figure 5-76
Display
Setting/selection
Start JOB
Set first JOB to get (setting: 129 to 256, factory setting 129).
Get JOB number
Set maximum selectable jobs (setting: 1 to 128, factory setting 10).
Additional parameter after activating the BLOCK JOB function.
The settings are defined in the machine configuration menu > see 5.18 chapter.
The setting of the max. number of JOBs is intended solely for torch modes 4, 5 and 6 or 14, 15
and 16 (no tapping function).
5.14 Interfaces for automation
WARNING
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
• Appoint only skilled persons for repair work (trained service personnel)!
Damage to the machine due to improper connection!
Unsuitable control leads or incorrect connection of input and output signals can cause damage
to the machine.
• Only use shielded control leads!
• If the machine is to be operated with control voltages connection via suitable isolation
amplifiers is required!
• To control the main or secondary current via control voltages, the relevant inputs must be
enabled (see specification for activation of control voltage).