Design and function
Installation
099-000118-EW501
24.11.2017
37
5.5.3
Mains connection
DANGER
Hazards caused by improper mains connection!
An improper mains connection can cause injuries or damage property!
• For hot wire welding, this machine may only be connected to the primary power source
(Tetrix series) via the connection intended for this power source.
• Mains plug, socket and lead must be checked regularly by an electrician!
Figure 5-12
Item Symbol
Description
0
1
Mains connection cable
Connection to TIG power source for hot wire application
2
Mains connection, hot wire power source
Power supply for hot wire power source
• Insert mains plug of the switched-off machine into the appropriate socket on the TIG power source.