Appendix B
Parameter overview
– setting ranges
099-000118-EW501
24.11.2017
119
11
Appendix B
11.1 Parameter overview
– setting ranges
11.1.1 TIG welding
Parameter
TIG/plasma
Display
Setting range
Comment
Co
d
e
Un
it
S
tand
ar
d
Min.
Max.
Gas pre-flow time
s
0,5
0
-
20
Ignition current AMP%
%
20
1
-
200
% of main current AMP
Up-slope time
s
1,0
0,0
-
20,0
Pulse time
s
0,01 0,00 -
20,0
Slope time
s
0,10 0,00 -
20,0 Time from main current AMP to
secondary current AMP%
Secondary current AMP%
%
50
1
200
% of main current AMP
Pulse pause time
s
0,01 0,00 -
20,0
Slope time
s
0,10 0,00 -
20,0 Period from secondary current
AMP% to main current AMP
Down-slope time
s
1,0
0,0
-
20,0
End current AMP%
%
20
1
-
200
% of main current AMP
Gas post-flow time
s
8
0,0
-
40,0
spotArc time
s
2
0,01 -
20,0
spotmatic time (
>
)
ms
200
5
-
999
spotmatic time (
>
)
s
2
0,01 -
20,0
activArc
0
-
100
Up/down speed
%
10
1
-
100
x0.01% of main current AMP
Current jump
A
1
1
-
20
Pulse balance
%
1
-
99
Pulsing, metallurgical
Pulse frequency
Hz
50
5
- 15000 Pulsing, metallurgical
11.1.2 MMA welding
Parameter
MMA
Display
Setting range
Comment
Co
d
e
Un
it
S
tand
ar
d
Min.
Max.
Hot start current
%
120
1
-
200
% of main current AMP (set
parameter
to
)
Hot start time
s
0,5
0,0
-
10,0
Arcforce
0
-40
-
40
Pulse frequency
Hz
1.2
0.2
-
500
Pulse balance
30
1
-
99