Design and function
Welding data display
34
099-000109-EW501
23.08.2018
5.1.8.1 Mains configuration
The machine may be connected to:
• a three-phase system with four conductors and an earthed neutral conductor
• a three-phase system with three conductors of which any one can be earthed,
e.g. the outer conductor
Figure 5-6
Legend
Item
Designation
Colour code
L1
Outer conductor 1
brown
L2
Outer conductor 2
black
L3
Outer conductor 3
grey
N
Neutral conductor
blue
PE
Protective conductor
green-yellow
• Insert mains plug of the switched-off machine into the appropriate socket.
5.2
Welding data display
The following welding parameters can be displayed before (nominal values), during (actual values) or af-
ter welding (hold values):
left-hand display
Parameter
Before welding
(nominal values)
During welding
(actual values)
After welding
(hold values)
Welding current
Parameter times
Parameter currents
right-hand display
Material thickness
Welding voltage
JOB number
Program number
When the settings are changed (e.g. welding current) after welding when the hold values are displayed,
the display will be switched to the relevant nominal values.
If the "Program number" signal light is on in addition to the "Material thickness" signal light, the user is in
program mode (programs 1-15, ,
> see 5.6 chapter
).
If the "JOB-number" signal light is on in addition to the "Material thickness" light, the user is in a JOB in
the free memory (JOB 128 to 256,
> see 5.5.2 chapter
).